TX-D
2. Specifications
Notes: *1 M.B.B. type models are only available in 2,500 V surge breakdown voltage type.
*2 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level])
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temper ature rise value. Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES (Page 24).
Characteristics Item Specifications
Contact
Arrangement 2 Form C 2 Form D (M.B.B.type)*1
Contact resistance (Initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Rating
Nominal switching capacity Standard contact: 2 A 30 V DC,
AgPd contact: 1 A 30 V DC (resistive load) 1 A 30 V DC (resistive load)
Max. switching power Standard contact: 60 W (DC),
AgPd contact: 30 W (DC) (resistive load) 30 W (DC) (resistive load)
Max. switching voltage 220 V DC 110 V DC
Max. switching current Standard contact: 2 A, AgPd contact: 1 A 1 A
Min. switching capacity (Reference value)*210µA10mV DC
Nominal operating
power
Single side stable
Surge breakdown voltage
2,500 V and 6,000 V types:
200mW (1.5 to 12 V DC), 230mW (24 V DC)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
280mW (1.5 to 12 V DC), 310mW (24 V DC)
250mW (1.5 to 12 V DC), 270mW (24 V DC)
1 coil latching
Surge breakdown voltage
2,500 V and 6,000 V types:
150mW (1.5 to 12 V DC), 170mW (24 V DC)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
230mW (1.5 to 12 V DC), 250mW (24 V DC)
—
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
Breakdown
voltage (Initial)
Between open contacts
Surge breakdown voltage
2,500 V and 6,000 V types:
1,000 Vr ms for 1min. (Detection current: 10mA)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
1,500 Vr ms for 1min. (Detection current: 10mA)
500 Vr ms for 1min. (Detection current: 10mA)
Between contact and coil
Surge breakdown voltage 2,500 V type:
2,000 Vr ms for 1min. (Detection current: 10mA)
Surge breakdown voltage 6,000 V and
6,000 V (High breakdown voltage) types:
3,000 Vr ms for 1min. (Detection current: 10mA)
2,000 Vr ms for 1min. (Detection current: 10mA)
Between contact sets 1,000 Vrms for 1min. (Detection current: 10mA)
Surge breakdown
voltage (Initial)
Between open contacts 1,500 V (10×160µs) (FCC Part 68) —
Between contacts and
coil*1
Surge breakdown voltage 2,500 V type:
2,500 V, 2 × 10µs (Telcordia)
Surge breakdown voltage 6,000 V and 6,000 V
(High breakdown voltage) types:
6,000 V, 1.2 × 50µs
2,500 V, 2 × 10µs (Telcordia)
Temperature rise (at 20°C 68°F)Max. 50°C 122°F
(By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 2A [1A: M.B.B.].)
Operate time [Set time] (at 20°C 68°F)Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20°C 68°F)Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock
resistance Functional Min. 750 m/s2
(Half-wave pulse of sine wave: 6 ms;
detection time: 10µs.)
Min. 500 m/s2
(Half-wave pulse of sine wave: 11 ms;
detection time: 10µs.)
Destructive Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6 ms.)
Vibration
resistance Functional 10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
Destructive 10 to 55 Hz at double amplitude of 5 mm
Expected life Mechanical Min. 108 (at 180 cpm) Min. 107 (at 180 cpm)
Electrical Min. 105 (2 A 30 V DC resistive),
Min. 5×105 (1 A 30 V DC resistive) (at 20 cpm) Min. 105 (1 A 30 V DC resistive) (at 20 cpm)
Conditions Conditions for operation, transport and
storage*3Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed (at rated load) 20 cpm
Unit weight Approx. 2 g .071 oz
ASCTB19E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e