NMV 5V, 12V & 15V Series www.murata-ps.com 3kVDC Isolated 1W Single & Dual Output DC/DC Converters Industry standard pinout Power sharing on dual output 3kVDC isolation (1 minute) `Hi-Pot Test' 5V, 12V, & 15V input 5V, 9V, 12V and 15V output Internal SMD construction No external components required MTTF up to 4.2 million hours No electrolytic or tantalum capacitors Pin compatible with MEV1, MEV3 & NMK series PRODUCT OVERVIEW The NMV series of industrial temperature range DC/DC converters are the standard buliding blocks for on-board distributed power systems. They are ideally suited for providing local supplies on control system boards with the added benefit of 3kVDC galvanic isolation to reduce switching noise. Available in SIP and DIP with dual and single output pinout. All of the rated power may be drawn from a single pin provided the total load does not exceed 1 watt. mVp-p 17 15 16 11 23 15 15 14 14 8.5 19 17 16 14 22 17 17 14 13 14 9 9 9 17 9.4 8 8.2 12 9 8.5 8 13 11 10 13 12 9 9 % pF kHrs 68 75 77 78 68 75 77 78 69 74 77 77 69 74 77 77 67 75 77 71.5 76 78 79 71.5 76 78 79 71 74 75 76 71 74 75 76 69 75 77 23 30 26 27 23 30 26 27 26 35 43 42 26 35 43 42 21 45 50 21 24 26 27 21 24 26 27 27 35 42 41 27 35 42 41 39 68 84 4241 3376 2555 1838 4241 3376 2555 1838 2664 2295 1883 1462 2664 2295 1883 1462 2747 1365 941 3106 2258 1579 1065 3106 2258 1579 1065 2148 1705 1287 924 2148 1705 1287 924 1941 789 522 Package Style 15 11.3 10.5 8.7 16 12 11 11 9.5 7 8 8 11 7.5 9 8.5 15.5 11.2 11 11 7.5 6.7 6 11 7 6.7 6.3 8.6 6.5 6.2 5.5 10 8 6 6.5 11 7.5 7.5 MTTF1 15 10 8.0 7.3 15 10 8.0 7.3 15 10 8.0 7.3 15 10 8.0 7.3 10 4.0 4.0 10 8.5 7.5 8.5 10 8.5 7.5 8.5 10 8.5 7.5 8.5 10 8.5 7.5 8.5 10 3.0 3.0 % 14.6 9.3 7.4 6.7 14.6 9.3 7.4 6.7 14.6 9.3 7.4 6.7 14.6 9.3 7.4 6.7 8.3 3.3 2.8 9.0 7.5 6.8 6.8 9.0 7.5 6.8 6.8 9.0 7.5 6.8 6.8 9.0 7.5 6.8 6.8 5.5 2.6 2.3 Ripple & Noise (Max) 294 267 260 256 294 267 260 256 121 113 108 108 121 113 108 108 93 85 84 280 263 256 253 280 263 256 253 117 113 111 110 117 113 111 110 91 87 84 Load Regulation (Typ) Input Current at Rated Load mA 200 111 84 67 200 111 84 67 200 111 84 67 200 111 84 67 200 84 67 100 55 42 33 100 55 42 33 100 55 42 33 100 55 42 33 100 42 33 Isolation Capacitance UL 60950 recognised for functional insulation mA 5 9 12 15 5 9 12 15 5 9 12 15 5 9 12 15 5 12 15 5 9 12 15 5 9 12 15 5 9 12 15 5 9 12 15 5 12 15 Efficiency Single or dual output V 5 5 5 5 5 5 5 5 12 12 12 12 12 12 12 12 15 15 15 5 5 5 5 5 5 5 5 12 12 12 12 12 12 12 12 15 15 15 Ripple & Noise (Typ) Wide temperature performance at full 1 Watt load, -40C to 85C V Load Regulation (Max) Efficiency to 79% NMV0505DAC NMV0509DAC NMV0512DAC NMV0515DAC NMV0505SAC NMV0509SAC NMV0512SAC NMV0515SAC NMV1205DAC NMV1209DAC NMV1212DAC NMV1215DAC NMV1205SAC NMV1209SAC NMV1212SAC NMV1215SAC NMV1505SAC NMV1512SAC NMV1515SAC NMV0505DC NMV0509DC NMV0512DC NMV0515DC NMV0505SC NMV0509SC NMV0512SC NMV0515SC NMV1205DC NMV1209DC NMV1212DC NMV1215DC NMV1205SC NMV1209SC NMV1212SC NMV1215SC NMV1505SC NMV1512SC NMV1515SC Output Voltage FEATURES Nominal Input Voltage Order Code Output Current SELECTION GUIDE DIP SIP DIP SIP DIP SIP DIP SIP INPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Voltage range Continuous operation, 5V input types Continuous operation, 12V input types Continuous operation, 15V input types 4.5 10.8 13.5 5 12 15 20 5.5 13.2 16.5 40 Reflected ripple current Units V mA p-p 1. Calculated using MIL-HDBK-217F with nominal input voltage at full load. For full details go to www.murata-ps.com/rohs All specifications typical at TA=25C, nominal input voltage and rated output current unless otherwise specified. www.murata-ps.com/support KDC_NMV.H02 Page 1 of 6 NMV 5V, 12V & 15V Series 3kVDC Isolated 1W Single & Dual Output DC/DC Converters ABSOLUTE MAXIMUM RATINGS Lead temperature 1.5mm from case for 10 seconds Input voltage VIN, NMV05 types Input voltage VIN, NMV12 types Input voltage VIN, NMV15 types 260C 7V 15V 18V OUTPUT CHARACTERISTICS Parameter Conditions TA=-40C to 120C, see derating graph Rated Power Voltage Set Point Accuracy Line regulation Min. See tolerance envelope High VIN to low VIN Typ. Max. Units 1 W 1.0 1.2 %/% Typ. Max. Units ISOLATION CHARACTERISTICS Parameter Conditions Min. Isolation test voltage Resistance Flash tested for 1 minute Viso= 1000VDC 3000 10 Parameter Conditions Min. Switching frequency 5V input types 12V input types 15V input types VDC G GENERAL CHARACTERISTICS Typ. Max. Units 120 150 90 135 170 110 kHz Typ. Max. Units 85 125 28 25 C TEMPERATURE CHARACTERISTICS Parameter Conditions Min. Specification Storage All output types -40 -50 Case Temperature above ambient TEMPERATURE DERATING GRAPH TOLERANCE ENVELOPE +10% Output Power (W) 1.5 85C 1.0 0.5 +5% VNOM Safe Operating Area 120C 0 -40 100 50 0 Ambient Temperature (C) 150 Output Voltage Cooling 5V output types All other output types Free air convection Typical L oad Line +2.5% -2.5% -7.5% 10 75 50 25 Output Load Current (%) 100 The voltage tolerance envelope shows typical load regulation characteristics for this product series. The tolerance envelope is the maximum output voltage variation due to changes in output loading. RoHS COMPLIANCE INFORMATION This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260C for 10 seconds. The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this series are backward compatible with Sn/Pb soldering systems. For further information, please visit www.murata-ps.com/rohs www.murata-ps.com/support KDC_NMV.H02 Page 2 of 6 NMV 5V, 12V & 15V Series 3kVDC Isolated 1W Single & Dual Output DC/DC Converters TECHNICAL NOTES ISOLATION VOLTAGE `Hi Pot Test', `Flash Tested', `Withstand Voltage', `Proof Voltage', `Dielectric Withstand Voltage' & `Isolation Test Voltage' are all terms that relate to the same thing, a test voltage, applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation. Murata Power Solutions NMV series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 minute. A question commonly asked is, "What is the continuous voltage that can be applied across the part in normal operation?" The NMV has been recognised by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according to safety standard requirements. REPEATED HIGH-VOLTAGE ISOLATION TESTING It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials, construction and environment. The NMV series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage. This consideration equally applies to agency recognised parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further insulation system of physical spacing or barriers. SAFETY APPROVAL The NMV series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation. The NMV Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below. NMV05xxxxC: 0.5A NMV12xxxxC: 0.2A NMV15xxxxC: 0.2A All fuses should be UL recognised and rated to at least the maximum allowable DC input voltage. File number E151252 applies. APPLICATION NOTES Minimum load The minimum load to meet datasheet specification is 10% of the full rated load across the specified input voltage range. Lower than 10% minimum loading will result in an increase in output voltage, which may rise to typically double the specified output voltage if the output load falls to less than 5%. Capacitive loading and start up Typical start up times for this series, with a typical input voltage rise time of 2.2s and output capacitance of 10F, are shown in the table below. The product series will start into a capacitance of 47F with an increased start time, however, the maximum recommended output capacitance is 10F. Typical Start-Up Wave Form NMV0505xC NMV0509xC NMV0512xC NMV0515xC NMV1205xC NMV1209xC Start-up time s 1966 5360 11180 16270 1290 4140 NMV1212xC NMV1215xC NMV1505xC NMV1512xC NMV1515xC Start-up time s 8650 11171 803 3510 8361 www.murata-ps.com/support KDC_NMV.H02 Page 3 of 6 NMV 5V, 12V & 15V Series 3kVDC Isolated 1W Single & Dual Output DC/DC Converters APPLICATION NOTES (continued) Ripple & Noise Characterisation Method Ripple and noise measurements are performed with the following test configuration. C1 1F X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter 10F tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less C2 than 100m at 100 kHz C3 100nF multilayer ceramic capacitor, general purpose R1 450 resistor, carbon film, 1% tolerance R2 50 BNC termination T1 3T of the coax cable through a ferrite toroid RLOAD Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires Measured values are multiplied by 10 to obtain the specified values. Differential Mode Noise Test Schematic DC/DC Converter OSCILLOSCOPE C1 C2 C3 + SUPPLY Input - R1 R2 T1 + Y INPUT Output - R LOAD Output Ripple Reduction By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max. Component selection Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended. The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter. Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be >20MHz. L DC Power Source NMV0505xC NMV0509xC NMV0512xC NMV0515xC NMV1205xC NMV1209xC NMV1212xC NMV1215xC NMV1505xC NMV1512xC NMV1515xC L, H 22 100 150 220 22 100 150 220 22 150 220 Inductor SMD 82223C 82104C 82154C 82224C 82223C 82104C 82154C 82224C 82223C 82154C 82224C C Load DC Through Hole 11R223C 11R104C 11R154C 11R224C 11R223C 11R104C 11R154C 11R224C 11R223C 11R154C 11R224C Capacitor C, F 1 0.47 0.33 0.22 2.2 1 0.33 0.22 1 0.33 0.22 www.murata-ps.com/support KDC_NMV.H02 Page 4 of 6 NMV 5V, 12V & 15V Series 3kVDC Isolated 1W Single & Dual Output DC/DC Converters PACKAGE SPECIFICATIONS MECHANICAL DIMENSIONS DIP package SIP package 19.500.25 [0.7680.010] 19.500.25 [0.7680.010] NMV0505DC 6.000.25 [0.2360.010] XYYWW 9.800.25 [0.3860.010] 0.4 [0.016] MIN NMV0505SC 6.800.25 [0.2680.010] XYYWW 10.000.25 [0.3940.010] 4.100.5 [0.1610.020] 0.500.05 [0.0200.002] S 4.100.5 [0.1610.020] 2.54 [0.100] 5.08 [0.200] 0.500.05 [0.0200.002] 2.54 [0.100] (2.13 [0.084]) 5.08 [0.200] 0.250.05 [0.0100.002] 7 1 (1.09 [0.043]) 1 7.62 [0.300] 10 14 * 9 8 2 5 * 6 7 0.250.05 [0 .0100.002] (1.13 [0.044]) 2.54 [0.100] (1.93 [0.076]) 15.24 [0.600] 15.24 [0.600] * Pin not fitted on single output variants. All dimensions in mm (inches) Controlling dimension is mm. All pins on a 2.54 (0.100) pitch and within 0.1 (0.004) of true position from pin 1 at seating plane `S' Weight: 2.4g (DIP) 2.1g (SIP) PIN CONNECTIONS Single output variants Pin 14 Pin DIP Function 1 7 8 10 14 -VIN NC +VOUT -VOUT +VIN Pin 1 2 5 7 Dual output variants 7 Pin SIP Function +VIN -VIN -VOUT +VOUT Pin 14 Pin DIP Function 1 7 8 9 10 14 -VIN NC +VOUT OV -VOUT +VIN Pin 1 2 5 6 7 7 Pin SIP Function +VIN -VIN -VOUT OV +VOUT www.murata-ps.com/support KDC_NMV.H02 Page 5 of 6 NMV 5V, 12V & 15V Series 3kVDC Isolated 1W Single & Dual Output DC/DC Converters PACKAGE SPECIFICATIONS (continued) RECOMMENDED FOOTPRINT DETAILS 14 Pin DIP Package 7 Pin SIP Package x5 HOLES 0.045 O 1.15 1.00 O 0.039 2.54 [0.100] [ ] 2.54 [0.100] 2.54 [0.100] * * x5 HOLES O 0.045 0.039 O 1.15 1.00 [ ] 2.54 [0.100] *Hole not required for single output variants. TUBE OUTLINE DIMENSIONS 14 Pin DIP Tube 7 Pin SIP Tube 12.0 [0.472] 9.3 [0.366] 12.43 [0.489] 14.5 [0.571] 18.0 [0.709] 5.070.80 [0.2000.03] 5.05 [0.199] Unless otherwise specified all dimensions in mm [inches] 0.55mm [0.022].Tube length (14 Pin DIP) : 520mm [20.472] 2.0 [0.079]. Tube length (7 Pin SIP) : 520mm [20.472] 2.0 [0.079]. Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED 5.0 [0.197] Tube Quantity : 25 This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2017 Murata Power Solutions, Inc. www.murata-ps.com/support KDC_NMV.H02 Page 6 of 6