ICM7555, ICM7556
FN2867 Rev.10.01 Page 3 of 13
Mar 5, 2020
Absolute Maximum Ratings Thermal Information
Supply Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +18V
Input Voltage
Trigger, Control Voltage, Threshold,
Reset (Note 4). . . . . . . . . . . . . . . . . . . . . . . . . . . . . V+ +0.3V to GND -0.3V
Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100mA
ESD Rating
Human Body Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2kV
Charged Device Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100V
Operating Conditions
Temperature Range
ICM7555C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
ICM7555I, ICM7556I . . . . . . . . . . . . . . . . . . . . . . . . . . . . -25°C to +85°C
Thermal Resistance (Typical, Notes 5, 6)θJA (°C/W) θJC (°C/W)
14 Ld PDIP Package* . . . . . . . . . . . . . . . . 115 46
8 Ld PDIP Package* . . . . . . . . . . . . . . . . . 130 69
8 Ld SOIC Package. . . . . . . . . . . . . . . . . . . 170 67
Maximum Junction Temperature (Hermetic Package) . . . . . . . . . . . .+175°C
Maximum Junction Temperature (Plastic Package) . . . . . . . . . . . .+150°C
Maximum Storage Temperature Range . . . . . . . . . . . . . -65°C to +150°C
* Pb-free PDIPs can be used for through-hole wave solder
processing only. They are not intended for use in Reflow solder
processing applications.
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
NOTES:
4. Due to the SCR structure inherent in the CMOS process used to fabricate these devices, connecting any terminal to a voltage greater than V+ +0.3V
or less than V- -0.3V may cause destructive latch-up. For this reason it is recommended that no inputs from external sources not operating from the
same power supply be applied to the device before its power supply is established. In multiple supply systems, the supply of the ICM7555 and
ICM7556 must be turned on first.
5. θJA is measured with the component mounted on a low effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
6. For θJC, the “case temp” location is taken at the package top center.
Electrical Specifications Applies to ICM7555 and ICM7556, unless otherwise specified.
PARAMETER SYMBOL TEST CONDITIONS
TA = +25°C
UNITMIN TYP MAX
Static Supply Current IDD ICM7555 VDD = 5V 40 200 µA
VDD = 15V 60 300 µA
ICM7556 VDD = 5V 80 400 µA
VDD = 15V 120 600 µA
Monostable Timing Accuracy RA = 10k, C = 0.1µF, VDD = 5V 2 %
µs
Drift with Temperature (Note 7)V
DD = 5V ppm/°C
VDD = 10V ppm/°C
VDD = 15V ppm/°C
Drift with Supply (Note 7)V
DD = 5V to 15V 0.5 %/V
Astable Timing Accuracy RA = RB = 10k, C = 0.1µF, VDD = 5V 2 %
µs
Drift with Temperature (Note 7)V
DD = 5V ppm/°C
VDD = 10V ppm/°C
VDD = 15V ppm/°C
Drift with Supply (Note 7)V
DD = 5V to 15V 0.5 %/V
Threshold Voltage VTH VDD = 15V 62 67 71 % VDD
Trigger Voltage VTRIG VDD = 15V 28 32 36 % VDD
Trigger Current ITRIG VDD = 15V 10 nA
Threshold Current ITH VDD = 15V 10 nA
Control Voltage VCV VDD = 15V 62 67 71 % VDD
Reset Voltage VRST VDD = 2V to 15V 0.4 1.0 V