TOSHIBA The HV6A(F)S Series 630A, 7.2kV Low Surge Circuit Breaker Fixed and Drawout Type The Toshiba HV6 series circuit breakers deliver big performance in a small package. Designed specifically for medium voltage, low capacity power receiving and transforming facilities the HV6 series capitalizes on Toshiba's 20+ years experience in vacuum interrupter technology. The HV6 series low surge characteristics coupled with its compact size make it ideal for a wide variety of applications including mobile power centers, portable substations and generator protection/paralleling. Whatever your industry or application no company provides more solutions your power distribution needs than Toshiba. Features and Benefits Feature Benefit Compact design Size reduction from use of axial-magnetic field interruption allows use in applications where traditional breakers won't fit. Multiple main terminal configurations available Select the configuration that best suits your application. Wide Variety Selection Breakers are available in Fixed or Drawout style, and manual or motor operated. Under-Voltage trip standard on all fixed mount configurations Front-mounted operations counter No capacitor trip device required. Provides positive tracking for maintenance purposes. High quality Toshiba vacuum interrupters Insure long life and low maintenance. Low Surge Interrupters - Low chopping current No special protective devices needed for motor starting and transformer loads. Design Information Operation Type Applicable Standards Control Circuit Connection Closing Voltage Tripping Voltage Auxiliary Contacts Motor Spring Operation Manual Operation JIS C 4603-1990, JEC-2300-1985 Plug/Terminal Connection 120VAC/125VDC or 24-30VDC 125VDC or 24-30VDC Std. 2NO-2NC / Max. 5NO-5NC Terminal Connection Manual Operation 125VDC or 24-30VDC Std. 2NO-2NC / Max. 5NO-5NC Specifications Model Number Maximum Continuous Current Rated Voltage Rated Interrupting Current (0.15 P.F.) Rated Frequency Transient Recovery Voltage Rated Making Current Rated Short-Time Current Rated Interrupting Time Basic Impulse Level (BIL) AC Withstand Voltage Operation Duty Mechanical Life Load Switching Life HV6AS-U HV6AS-L HV6FS-MU HV6FS-ML HV6FS-MLD 630A 7.2 / 4.8 & below 14kA / 16kA (Sym.) 50/60 Hz 0.32kV/microsec. at 4.2 kV & above, below 0.16kV/microsec. 31.5kA (Peak) 12.5kA - 2 Sec. Less than 3 Cycles 60kV 22kV - 1 Min. O - 1 min. - CO - 3 min. - CO 10,000 Operations 10,000 Operations Form Cont. Current Voltage AC Interrupting DC Interrupting Auxiliary Contacts 2NO-2NC (Standard) / 5NO-5NC (Optional) 10A 300V Max. - 48V Min. 700VA at PF 0.35 60W at L/R 150 ms Altitude (Above Derate by ANSI C37.04) Ambient Temperature Installation Operation Opening Time No Load Closing Time Closing Voltage, Current Charging Motor Voltage, Current Opening Voltage, Current Under Voltage Release Weight List Price o C Manual Closing - (Standard) lb. (kg) 125Vdc, 3A 3300 ft (1000 m) -5 to +40 Fixed Drawout Motor Spring Closing 20 ms (Typical) 30 ms 125Vdc/120Vac, 1.1A 125Vdc/120Vac, 2.5A Peak (0.9 Avg.) 125Vdc, 4.6A 0.4A at 120Vac (Trip Voltage 24 to 72Vac) 49 (22) 55 (25) 53 (24) 60 (27) $7,400 $10,800 N/A 84 (38) $12,500 Factory Installed Modifications Description Control Voltage Additional 3A/3B Auxiliary Contacts on HV6 Breaker (Aux. Block used is based on breaker control voltage) 125Vdc/120Vac Modification List Price Code Adder $1,100 E 24-32Vdc For direct replacement of fixed mount V16S Series (provides same faceplate dimensions). Not required on MLD (drawout) model. $1,300 No Charge /R Ordering Information & Model Number HV6AS - L - * V A E Field A Field B Field C Field D Field E Field F Breaker Series Type Closing Coil Voltage Trip Coil Voltage Suffix Factory Modifications A - Manually HV6AS U : Fixed/Manual Operation * - None (Manually Operated) S - 24/32Vdc HV6FS L : Fixed/Manual Operation S - 24/30Vdc V - 125Vdc MU : Fixed/Motor Operation V - 125Vdc/120Vac ML : Fixed/Motor Operation MLD : Drawout/Motor Operation E - For 3NO-3NC Additional Operated Auxiliary Contacts Breaker /R - Replaces V16 Series Only (same faceplate dimensions) Accessories AC Control Power Rectifier Model Number 4Z9G0362G003 Used for AC closing and tripping, Dual input 120VAC or 240VAC AC Capacitor Trip Device Model number CIT-10QA Used for AC shunt tripping (120 or 240VAC Input), Door Mounted