BCD.00285_AA_December-3-2013 3 www.power-one.com
Notes:
1. Peak current rating of 120% of max, < 30 Sec with max of 10% duty cycle.
2. Combined power from main output, Vfan and Vs/b should not exceed total power rating.
3. Fan output tolerance is ± 20%. When V1 full load, Vfan needs 20 mA load to be within regulation specification. Peak
current for fan output is 1 A.
4. Ripple is 2% up to 20% load and less than 1% above 20% load. Output noise measurement is made with a 20 MHz
bandwidth using a 6” twisted pair, terminated with a 10 uF tantalum capacitor in parallel with a 0.1 uF ceramic capacitor.
5. Specifications are for nominal input voltage, 25° C and max load unless otherwise stated.
6. Class 1 models have Earthing tab J4. Class 2 models (-2 suffix) have no Earthing tab.
7. Derate power linearly to 80% from 90 Vac to 80 Vac input.
8. Power supply shipped with J3 pin 1 and 2 shorted to enable main output
9. Specifications subject to change without notice.
10. Air flow over long edge (either direction) required for air flow rating. See mechanical drawing below.
11. Warranty 2 years.
General Specifications
PFC converter 80 kHz typical
Resonant converter: Variable 35 to 250
kHz, 90 kHz typical
Environmental
-20 to 70° C. See derating charts below.
EN55022, FCC part 15 Level B
EN55022, FCC part 15 Level B
To be controlled in end system
Electromagnetic Susceptibility
Signals
TTL signal goes high after main output is within regulation, delay is 0.1 to 0.3 sec
To turn on power supply short J3 pin 1 to J3 pin 2 or J3 pin 7
Compensates for 200 mV drop
Safety
EN60950-1+A12:2011, IEC60950-1 2nd+A1 2009, CSA-22.2 No 60950-01-07+ A1, UL60950-
1-2011