TECHNICAL DATA SHEET
6 Lake Street, Lawrence, MA 01841 Gort Road Business Park, Ennis, Co. Clare, Ireland
1-800-446-1158 / (978) 620-2600 / Fax: ( 978) 689-0803 Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298
Website: http: //www.microsemi.com
LOW POWER NPN SILICON TRANSISTOR
Qualified per MIL-PRF-19500/391
T4-LDS-0 18 5 Rev . 1 (1 0 17 2 6) Page 1 of 6
DEVICES LEVELS
2N3019 2N3057A 2N3700 JAN
2N3019S 2N3700S JANTX
2N3700UB JANTXV
JANS
ABSOLUTE MAXIMUM RATI NG S (TC = +25°C unless otherwise noted)
Parameters / Test Conditions Symbol Value Unit
Collector-Emitter Voltage VCEO 80 Vdc
Collector-Base Voltage VCBO 140 Vdc
Emitter-Base Voltage VEBO 7.0 Vdc
Collector Current IC 1.0 Adc
Total Power Dissipation
PT
@ TA = +25°C (1) W
2N3019; 2N3019S
2N3057A
2N3700, 2N3700UB
0.8
0.5
0.5
@ TC = +25°C (2) W
2N3019; 2N3019S
2N3057A
2N3700
2N3700UB
5.0
1.8
1.0
N/A
Operating & Storage Jct Temp Range TJ, Tstg -65 to +200 °C
NOTE:
1) Derate linearly 4.6 mW/°C for type 2N3019 and 2N3019S; 2.3 mW/°C for type 2N3057A;
2.85 mW/°C for type 2N3700; 6.6 mW/°C for type 2N3700UB for TA +25°C
2) Derate linearly 28.6 mW/°C for type 2N3019 and 2N3019S; 10.3 mW/°C for types
2N3057A, 2N3700 & 2N3700UB for TC +25°C.
ELECTRICAL CHARACTERISTICS (TA = +25°C, unless otherwise noted)
Parameters / Test Conditions Symbol Min. Max. Unit
OFF CHARACTERTICS
Collector-Emitter Breakdown Current
IC = 30mAdc V(BR)CEO 80 Vdc
Collector-Emitter Cutoff Current
VCE = 90Vdc ICES 10
ηAdc
Collector-Base Cutoff Current
VCB = 140V ICBO 10 µAdc
Emitter-Base Cutoff Current
VEB = 7.0Vdc
VEB = 5.0Vdc
IEBO 10
µAdc
ηAdc
TO-39 (TO-205AD)
2N3019, 2N3 019S
TO-18 (TO-206AA)
2N3700
TO-46 (TO-206AB)
2N3057A
3 PIN SURFACE MOUNT
2N3700UB
TECHNICAL DATA SHEET
6 Lake Street, Lawrence, MA 01841 Gort Road Business Park, Ennis, Co. Clare, Ireland
1-800-446-1158 / (978) 620-2600 / Fax: ( 978) 689-0803 Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298
Website: http: //www.microsemi.com
T4-LDS-0 18 5 Rev . 1 (1 0 17 2 6) Page 2 of 6
ELECTRICAL CHARACTERISTICS (TA = +25°C, unless otherwise noted) (CONT.)
Parameters / Test Conditions Symbol Min. Max. Unit
ON CHARACTERTICS
Forward-Current Transfer Ratio
hFE
IC = 150mAdc, VCE = 10Vdc
IC = 0.1mAdc, VCE = 10Vdc
IC = 10mAdc, VCE = 10Vdc
IC = 500mAdc, VCE = 10Vdc
IC = 1.0Adc, VCE = 10Vdc
100
50
90
50
15
300
300
300
Collector-Emitter Saturation Voltage
VCE(sat)
Vdc
IC = 150mAdc, IB = 15mAdc
IC = 500mAdc, IB = 50mAdc
0.2
0.5
Base-Emitter Saturation Voltage VBE(sat)
Vdc
IC = 150mAdc, IB = 15mAdc 1.1
DYNAMIC CHARACTERISTICS
Parameters / Test Conditions Symbol Min. Max. Unit
Small-Signal Short-Circuit Forward Current Transfer Ratio
hfe
IC = 1.0mAdc, VCE = 5.0Vdc, f = 1.0kHz 80 400
Magnitude of Small-Signal Short-Circuit Forward Current Transfer Ratio
|hfe|
IC = 50mAdc, VCE = 10Vdc, f = 20MHz 5.0 20
Output Capacitance
Cobo
pF
VCB = 10Vdc, IE = 0, 100 kHz f 1.0MHz 12
Input Capacitance
Cibo
pF
VEB = 0.5Vdc, IC = 0, 100 kHz f 1.0MHz 60
SAFE OPERATION AREA
DC Tests
TC = 25°C, 1cycle, t = 10ms
Test 1
2N3019, 2N3019S
2N3057A, 2N3700, 2N3700UB
VCE = 10Vdc
IC = 500mAdc
IC = 180mAdc
Test 2
2N3019, 2N3019S
2N3057A, 2N3700, 2N3700UB
VCE = 40Vdc
IC = 125mAdc
IC = 45mAdc
Test 3
2N3019, 2N3019S
2N3057A, 2N3700, 2N3700UB
VCE = 80Vdc
IC = 60mAdc
IC = 22.5mAdc
(1) Pulse Test: Pulse Width = 300µs, Duty Cycle 2.0%
TECHNICAL DATA SHEET
6 Lake Street, Lawrence, MA 01841 Gort Road Business Park, Ennis, Co. Clare, Ireland
1-800-446-1158 / (978) 620-2600 / Fax: ( 978) 689-0803 Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298
Website: http: //www.microsemi.com
T4-LDS-0 18 5 Rev . 1 (1 0 17 2 6) Page 3 of 6
PACKAGE DIMENSIONS
NOTES:
1. Dimension are in inches.
2. Millimeters are given for general information only.
3. Beyond r (radius) maximum, TW shall be held for a minimum length of .011 (0.28 mm).
4. Dimension TL measured from maximum HD.
5. Body contour optional within zone defined by HD, CD, and Q.
6. Leads at gauge plane .054 +.001 -.000 inch (1.37 +0.03 -0.00 mm) below seating plane shall be within
.007 inch (0.18 mm) radius of true position (TP) at maximum material condition (MMC) relative to tab at MMC.
The device may be measured by direct methods.
7. Dimension LU applies between L1 and L2. Dimension LD applies between L2 and minimum. Diameter is
uncontrolled in L1 and beyond LL minimum.
8. All three leads.
9. The collector shall be internally connected to the case.
10. Dimension r (radius) applies to both inside corners of tab.
11. In accordance with ASME Y14.5M, diameters are equivalent to φx symbology.
12. For "S" suffix devices, dimension LL is 0.500 (12.70 mm) minimum, 0.750 (19.05 mm) maximum.
13. "S" suffix devices, dimension LL is 0.50 (12.70 mm) minimum, 0.75 (19.05 mm) maximum.
14. "L" suffix devices, dimension LL is 1.500 (38.10 mm) minimum, 1.750 (44.45 mm) maximum. 13.
15. Lead 1 = emitter, lead 2 = base, lead 3 = collector.
FIGURE 1. Physical dimensions for device types 2N3019 (TO-5) and 2N3019S (TO-39).
Dimensions
Symbol Inches Millimeters Notes
Min Max Min Max
CD .305 .335 7.75 8.51
CH .240 .260 6.10 6.60
HD .335 .370 8.51 9.40
LC .200 TP 5.08 TP 6
LD .016 .021 0.41 0.53 7, 8
LL .500 .750 12.70 19.05 7, 8, 12
LU .016 .019 0.41 0.48 7, 8
L1 .050 1.27 7, 8
L2 .250 6.35 7, 8
Q .050 1.27 5
TL .029 .045 0.74 1.14 4
TW .028 .034 0.71 0.86 3
r .010 0.25 10
α45° TP 45° TP 6
P .100 2.54
TO-39
TO-5
TECHNICAL DATA SHEET
6 Lake Street, Lawrence, MA 01841 Gort Road Business Park, Ennis, Co. Clare, Ireland
1-800-446-1158 / (978) 620-2600 / Fax: ( 978) 689-0803 Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298
Website: http: //www.microsemi.com
T4-LDS-0 18 5 Rev . 1 (1 0 17 2 6) Page 4 of 6
NOTES:
1. Dimension are in inches.
2. Millimeters are given for general information only.
3. Beyond r (radius) maximum, TW shall be held for a minimum length of .011 inch (0.28 mm).
4. Dimension TL measured from maximum HD.
5. Leads at gauge plane .054 +.001 -.000 inch (1.37 +0.03 -0.00 mm) below seating plane shall be within
.007 inch (0.18 mm) radius of true position (TP) at maximum material condition (MMC) relative to tab at
MMC. The device may be measured by direct methods.
6. Dimension LU applies between L1 and L2. Dimension LD applies between L2 and LL minimum. Diameter is
uncontrolled in L1 and beyond LL minimum.
7. All three leads.
8. The collector shall be internally connected to the case.
9. Dimension r (radius) applies to both inside corners of tab.
10. In accordance with ASME Y14.5M, diameters are equivalent to φx symbology.
11. Lead 1 = emitter, lead 2 = base, lead 3 = collector.
FIGURE 2. Physical dimensions for 2N3057A (TO-46).
Dimensions
Symbol Inches Millimeters Note
Min Max Min Max
CD .178 .195 4.52 4.95
CH .065 .085 1.65 2.16
HD .209 .230 5.31 5.84
LC .100 TP 2.54 TP 6
LD .016 .021 0.41 0.53 7
LL .500 1.750 12.70 44.45 7
LU .016 .019 0.41 0.48 7
L1 .050 1.27 7
L2 .250 6.35 7
TL .028 .048 0.71 1.22 3
TW .036 .046 0.91 1.17 2
r .007 0.18 10, 11
α45° TP 45° TP 6
TECHNICAL DATA SHEET
6 Lake Street, Lawrence, MA 01841 Gort Road Business Park, Ennis, Co. Clare, Ireland
1-800-446-1158 / (978) 620-2600 / Fax: ( 978) 689-0803 Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298
Website: http: //www.microsemi.com
T4-LDS-0 18 5 Rev . 1 (1 0 17 2 6) Page 5 of 6
NOTES:
1. Dimension are in inches.
2. Millimeters are given for general information only.
3. Beyond r (radius) maximum, TH shall be held for a minimum length of .011 inch
(0.28 mm).
4. Dimension TL measured from maximum HD.
5. Body contour optional within zone defined by HD, CD, and Q.
6. Leads at gauge plane .054 +.001 -.000 inch (1.37 +0.03 -0.00 mm) below seating plane shall be within .007 inch (0.18 mm)
radius of true position (TP) at maximum material condition (MMC) relative to tab at MMC. The device may be measured by
direct methods or by the gauge and gauging procedure shown in figure 2.
7. Dimension LU applies between L1 and L2. Dimension LD applies between L2 and LL minimum. Diameter is uncontrolled in
L1 and beyond LL minimum.
8. All three leads.
9. The collector shall be internally connected to the case.
10. Dimension r (radius) applies to both inside corners of tab.
11. In accordance with ASME Y14.5M, diameters are equivalent to φx symbology.
12. Lead 1 = emitter, lead 2 = base, lead 3 = collector.
FIGURE 3. Physical dimensions for type 2N3700 (TO-18).
Dimensions
Symbol Inches Millimeters Note
Min Max Min Max
CD .178 .195 4.52 4.95
CH .170 .210 4.32 5.33
HD .209 .230 5.31 5.84
LC .100 TP 2.54 TP 6
LD .016 .021 0.41 0.53 7,8
LL .500 .750 12.70 19.05 7,8
LU .016 .019 0.41 0.48 7,8
L1 .050 1.27 7,8
L2 .250 6.35 7,8
P .100 2.54
Q .030 0.76 5
TL .028 .048 0.71 1.22 3,4
TW .036 .046 0.91 1.17 3
r .010 0.25 10
α45° TP 45° TP 6
1, 2, 9, 11, 12
TECHNICAL DATA SHEET
6 Lake Street, Lawrence, MA 01841 Gort Road Business Park, Ennis, Co. Clare, Ireland
1-800-446-1158 / (978) 620-2600 / Fax: ( 978) 689-0803 Tel: +353 (0) 65 6840044 Fax: +353 (0) 65 6822298
Website: http: //www.microsemi.com
T4-LDS-0 18 5 Rev . 1 (1 0 17 2 6) Page 6 of 6
Symbol
Dimensions
Note
Symbol
Dimensions
Note
Inches Millimeters Inches Millimeters
Min Max Min Max Min Max Min Max
BH .046 .056 1.17 1.42 LS1 .035 .039 0.89 0.99
BL .115 .128 2.92 3.25 LS2 .071 .079 1.80 2.01
BW .085 .108 2.16 2.74 LW .016 .024 0.41 0.61
CL .128 3.25 r .008 0.20
CW .108 2.74 r1 .012 0.31
LL1 .022 .038 0.56 0.96 r2 .022 0.56
LL2 .017 .035 0.43 0.89
NOTES:
1. Dimensions are in inches.
2. Millimeters are given for general information only.
3. Hatched areas on package denote metallized areas.
4. Pad 1 = Base, Pad 2 = Emitter, Pad 3 = Collector, Pad 4 = Shielding connected to the lid.
5. In accordance with ASME Y14.5M, diameters are equivalent to φx symbology.
FIGURE 4. Physical dimensions, surface mount (2N3700UB).