SFH 203 P
SFH 203 PFA
Silizium-PIN-Fotodiode
Silicon PIN Photodiode
Lead (Pb) Free Product - RoHS Compliant
SFH 203 P
SFH 203 PFA
2011-10-20 1
Wesentliche Merkmale
Wellenlängenbereich (S10%) 400nm bis 1100nm
(SFH 203 P) und 750nm bis 1100nm
(SFH 203 PFA)
Kurze Schaltzeit (typ. 5 ns)
5 mm-Plastikbauform im LED-Gehäuse
Anwendungen
Industrieelektronik
„Messen/Steuern/Regeln“
Schnelle Lichtschranken
Typ
Type
Bestellnummer
Ordering Code
Fotostrom, Ev=1000 lx, standard light A, VR = 5 V (SFH 203 P)
Photocurrent, Ee=1 mW/cm2, λ = 870nm, VR = 5 V(SFH 203 PFA)
Ip (μA)
SFH 203 P Q62702P0942 9.5 (5.0)
SFH 203 PFA Q62702P0947 6.2 (3.6)
Features
Wavelength range (S10%) 400 nm to 1100 nm
(SFH 203 P) and 750nm to 1100nm
(SFH 203 PFA)
Short switching time (typ. 5 ns)
5 mm LED plastic package
Applications
Industrial electronics
For control and drive circuits
High speed photointerrupters
2011-10-20 2
SFH 203 P, SFH 203 PFA
Grenzwerte
Maximum Ratings
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
Betriebs- und Lagertemperatur
Operating and storage temperature range
Top; Tstg – 40 + 100 °C
Sperrspannung
Reverse voltage
VR
VR (t<2min)
20
50
V
V
Verlustleistung
Total power dissipation
Ptot 150 mW
Kennwerte (TA = 25 °C)
Characteristics
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
SFH 203 P SFH 203 PFA
Fotostrom
Photocurrent
VR = 5 V, Normlicht/standard light A,
T = 2856 K, EV = 1000 lx
VR = 5 V, λ = 870 nm, Ee = 1 mW/cm2
IP
IP
9.5 (5.0)
6.2 (3.6)
μA
μA
Wellenlänge der max. Fotoempfindlichkeit
Wavelength of max. sensitivity
λS max 850 900 nm
Spektraler Bereich der Fotoempfindlichkeit
S = 10 % von Smax
Spectral range of sensitivity
S = 10 % of Smax
λ400 1100 750 1100 nm
Bestrahlungsempfindliche Fläche
Radiant sensitive area
A 11 mm
2
Abmessung der bestrahlungsempfindlichen Fläche
Dimensions of radiant sensitive area
L×B
L×W
1×11×1mm×mm
Halbwinkel
Half angle
ϕ±75 ±75 Grad
deg.
Dunkelstrom, VR = 20 V
Dark current
IR 1 ( 10) 1 ( 10) nA
Spektrale Fotoempfindlichkeit, λ = 850 nm
Spectral sensitivity
Sλ0.62 0.59 A/W
Quantenausbeute, λ = 850 nm
Quantum yield
η0.89 0.86 Electrons
Photon
SFH 203 P, SFH 203 PFA
2011-10-20 3
Leerlaufspannung
Open-circuit voltage
Ev = 1000 Ix, Normlicht/standard light A,
T = 2856 K
Ee = 0.5 mW/cm2, λ = 870 nm
VO
VO
350 ( 300)
300 ( 250)
mV
mV
Kurzschlußstrom
Short-circuit current
Ev = 1000 Ix, Normlicht/standard light A,
T = 2856 K
Ee = 0.5 mW/cm2, λ = 870 nm
ISC
ISC
9.3
3.0
μA
μA
Anstiegs- und Abfallzeit des Fotostromes
Rise and fall time of the photocurrent
RL = 50 Ω; VR = 20 V; λ = 850 nm; Ip = 800 μA
tr, tf55 ns
Durchlaßspannung, IF = 80 mA, E = 0
Forward voltage
VF1.3 1.3 V
Kapazität, VR = 0 V, f = 1 MHz, E = 0
Capacitance
C011 11 pF
Temperaturkoeffizient von VO
Temperature coefficient of VO
TCV– 2.6 – 2.6 mV/K
Temperaturkoeffizient von ISC
Temperature coefficient of ISC
Normlicht/standard light A
λ = 870 nm
TCI
0.18
0.1
%/K
Rauschäquivalente Strahlungsleistung
Noise equivalent power
VR = 20 V, λ = 850 nm
NEP 2.9 ×10– 14 2.9 ×10– 14
Nachweisgrenze, VR = 20 V, λ = 850 nm
Detection limit
D* 3.5 ×1012 3.5 ×1012
Kennwerte (TA = 25 °C)
Characteristics (cont’d)
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
Einheit
Unit
SFH 203 P SFH 203 PFA
W
Hz
------------
cm Hz×
W
--------------------------
SFH 203 P, SFH 203 PFA
2011-10-20 4
Relative Spectral Sensitivity
SFH 203 P, Srel = f (λ)
Photocurrent IP = f (Ee), VR = 5 V
Open-Circuit Voltage VO = f (Ee)
SFH 203 PFA
Directional Characteristics
Srel = f (ϕ)
λ
OHF01129
0
rel
S
400 600 800 1000 1200
20
40
60
80
%
100
nm
E
OHF01765
e
0
10
P
Ι
-2
10
10 110 210 4
10 -1
10 0
10 1
10 24
10
3
10
2
10
1
10
10 0
VO
μAmV
Ι
P
VO
2
W/cmμ
Relative Spectr. Sensitivity
SFH 203 PFA, Srel = f (λ)
Photocurrent IP = f (Ev), VR = 5 V
Open-Circuit Voltage VO = f (Ev)
SFH 203 P
λ
OHF01773
0
rel
S
400 600 800 1000 1200
20
40
60
80
%
100
nm
E
OHF01025
V
0
10
P
Ι
-1
10
10
1
10
2
10
4
10
0
10
0
V
O
μAmV
Ι
P
V
O
10
3
lx
1
10
2
10 10
3
10
2
1
10
Total Power Dissipation
Ptot = f (TA)
Dark Current
IR = f (VR), E = 0
Capacitance
C = f (VR), f = 1 MHz, E = 0
T
OHF00394
A
0
tot
P
020 40 60 80 ˚C 100
mW
20
40
60
80
100
120
140
160
V
OHF01026
R
R
Ι
0
4
10
3
10
2
10
10
1
pA
20 V 3010
SFH 203 P, SFH 203 PFA
2011-10-20 5
Maßzeichnung
Package Outlines
Maße in mm (inch) / Dimensions in mm (inch).
Lötbedingungen
Soldering Conditions
Wellenlöten (TTW) (nach CECC 00802)
TTW Soldering (acc. to CECC 00802)
0.6 (0.024)
0.4 (0.016)
5.9 (0.232)
5.5 (0.217)
1.0 (0.039)
0.5 (0.020)
3.85 (0.152)
3.35 (0.132)
5.0 (0.197)
4.2 (0.165)
29 (1.142)
27 (1.063)
1.8 (0.071)
1.2 (0.047)
2.54 (0.100)
spacing
0.6 (0.024)
0.4 (0.016)
0.8 (0.031)
0.4 (0.016)
ø5.1 (0.201)
ø4.8 (0.189)
Chip position
Area not flat
GEOY6648
Cathode
2011-10-20 6
SFH 203 P, SFH 203 PFA
Published by
OSRAM Opto Semiconductors GmbH
Leibnizstraße 4, D-93055 Regensburg
www.osram-os.com
© All Rights Reserved.
Attention please!2011-10-20The information describes the type of component and shall not be considered as
assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may
contain dangerous substances. For information on the types in question please contact our Sales
Organization.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components 1 , may only be used in life-support devices or systems 2 with the express written approval of OSRAM OS.
1 A critical component is a component usedin a life-support device or system whose failure can reasonably be expected
to cause the failure of that life-support device or system, or to affect its safety or effectiveness of that device or system.
2 Life support devices or systems are intended (a) to be implanted in the human body, or (b) to support and/or maintain
and sustain human life. If they fail, it is reasonable to assume that the health of the user may be endangered.