Contact Amphenol Aerospace for more information at 800-678-0141 • www.amphenol-aerospace.com 225
Amphenol
II
Dualok
III
SJT
38999
I
PCB
Accessories
Aquacon
HD
Herm/Seal
Fiber
Optics
Contacts
Connectors
Cables
HIGH
SPEED
26482
Matrix 2 83723 III
Matrix|Pyle
5015
Crimp Rear
Release
Matrix
26500
Pyle 22992
Class L Back-
Shells
Options
Others
EMI Filter
Transient
Quadrax Contacts for MIL-DTL-38999
Series III, Application Data
TV-R Series, MIL-DTL-38999 Series III* Connectors
QU ADRAX CONTA CTS FOR USE IN TV -R CONNECT ORS
Cable
Contact Part Number
(Termination Instruction Sheet)** Impedance
(Ohms)
Inner
Conductor
(AWG)
Contact
Size
Electrical
Protocol†† Crimping Tools
Pin Socket Inner Contact Outer Contact
Draka Fileca F-4703-3, F4704-4,
Filotex ET 2PC236, Filotex
ET2PF870, PIC Wire E50424
ABS0972, Tensolite
23450/04090X-4(LD) Draka Fileca
F-4704-5, ABS1503 KD 24
21-033384-021
(L-2119-A) 21-033385-021
(L-2119-A)
100
24
8
Ethernet, 1000 Base-T
Gigabit Ethernet
M22520/2-01
with Positioner
M22520/2-37
or with Daniels
Positioner
K709
M22520/5-01
with Die Set
M22520/5-45
(Location A)
Tensolite NF24Q100, NF24Q100-01,
24443/9P025X-4(LD), S280W502-4,
24443/03130X-4(LD),
24443/C20714X-4(LD),
24450/0120X-4(LD),
NF24-2Q100, TYCO CEC-
RWC-18664, GORE GSC-01-
81869-01, 24443/03166X-4(LD),
Thermax T956-4T200, Pic Wire
E51424, Thermax MX100Q-24,
NF24Q100-01-200C (Space),
BMS13-72T03C04G024
21-033384-051
(L-2119-D) 21-033385-051
(L-2119-D) 24 Ethernet, 1000 Base-T
Gigabit Ethernet
Tensolite NF22Q100,
NF22Q100-01, Thermax 956-5,
GORE RCN 7688
21-033384-061
(L-2119-H) 21-033385-061
(L-2119-H) 22 Ethernet (100 Mbps),
1000 Base-T Gigabit
Ethernet (1 Gbps)
Tensolite NF26Q100, NF26Q100-01,
NF26-2Q100, PIC E51426,
Wirenetics W-3714-379
21-033384-071
(L-2119-AB) 21-033385-071
(L-2119-AB) 26 Ethernet (100 Mbps),
1000 Base-T Gigabit
Ethernet (1 Gbps)
S280W502-4/BMS13-
72T03C04G024
21-033384-141
(BACC47GM1) 21-033385-141
(BACC45GN1) 24
Draka Fileca F-4704-6,
Gore RCN 8672
21-033384-151
(L-2119-AW) 21-033385-151
(L-2119-AW) 26 Ethernet (100 Mbps),
1000 Base-T Gigabit
Ethernet (1 Gbps)
Tensolite NF24Q100-01 (same as
21-03338( )
-51, uses EMI Piggyback)
21-033384-161
(L-2119-BE) 21-033385-161
(L-2119-BE) 24 Ethernet (100 Mbps),
1000 Base-T Gigabit
Ethernet (1 Gbps)
Gore RCN8513, JSFY18-3 21-033384-171
(L-2119-BN) 21-033385-171
(L-2119-BN) 22 Ethernet (100 Mbps),
1000 Base-T Gigabit
Ethernet (1 Gbps)
Tensolite NF22Q100 Special Box
pattern, only mates with 21-0333
( )-181
21-033384-181
(L-2119-BP) 21-033384-181
(L-2119-BP) 22 Ethernet (100 Mbps),
1000 Base-T Gigabit
Ethernet (1 Gbps)
Tensolite NF24Q100, NF24Q100-01
for 2.5 Gbps applications
21-033384-191
(L-2119-BS) 21-033385-191
(L-2119-BS) 24
•Serial FPDP Applications
(2.5 Gbps) (Typical app
run at 150 Ohms)
• HDMI 1.3
Gore RCN 8647 21-033384-301 21-033385-301 24
USB2 (28433/02171LX-4) 21-033384-101† 21-033385-101† 90 USB2.0 (480 Mbps)
Tensolite 24450/03089X-4(LD)
Gore RCN8647 21-033384-211 21-033385-211
110
24 IEEE 1394B Firewire
JSFY02-1, JSFY18 21-033384-221 21-033385-221 24 IEEE 1394B Firewire
Gore RCN8487, JSFY18 21-033384-231 21-033385-231 24 IEEE 1394B Firewire
Tensolite 24450/03089X-4(LD)
Same as 21-03338( )-211 but Box
pattern, mates with 21-03338( )-241
only
21-033384-241† 21-033385-241† 24 IEEE 1394B Firewire
F-4703, ABS1503KD24 21-033384-281 21-033385-281 100 Meets EN3155-074
Tensolite 26473/02006X-4(LD)/Gore
RCN8328 (not for new designs, use
21-033450/1 series)
21-033384-31
(L-2119-B) 21-033385-031
(L-2119-B) 150 26
Daniels crimping tools available from Daniels Mfg. Corp. 6103 Anno Ave.,
Orlando, FL 32809
* Requires modied connector to accommodate keyed contacts.
**Termination instructions are packaged with each contact and can be
found on-line at: www.amphenol-aerospace.com/serviceinstructions.asp
† Consult Amphenol for current release of this contact or instruction sheet if applicable.
†† Test reports available for indicated protocols. Consult Amphenol
Aerospace. Typical applications run at 150 Ohms
CHART CONTINUES ON NEXT PAGE
QU ADRAX CONTA CT DATA
Contacts are inserted by hand. Refer to termination instructions listed. Contacts are
removed with a removal tool. Recommended tool is MIL-I-81969/14-06, Daniels DRK-264-8.
Refer to termination instructions listed. Finish of mating contact parts: Contact part numbers
shown in the chart above are sup plied gold plated per ASTM B488 Type II, Code C, .000050
min. thick over nickel plate per AMS-QQ-N-290, Class 2, .000030/.000150 thick.