719 Series Pressure Calibrator with Electric Pump Users Manual August 2008 (c) 2008 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies. LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for three years (one year for pump assembly) from the date of purchase. This warranty does not cover fuses, disposable batteries or damage from accident, neglect, misuse or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke's behalf. To obtain service during the warranty period, send your defective Calibrator to the nearest Fluke Authorized Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. 11/99 Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands Table of Contents Title Page Introduction .................................................................................................................... Safety Information .......................................................................................................... Getting Acquainted with the Calibrator ........................................................................... HART Resistor........................................................................................................... Power Saver .............................................................................................................. Switch Test..................................................................................................................... Zeroing with Absolute Pressure Modules ....................................................................... Set Maximum Pressure Limit ......................................................................................... Calibrating a P/I Transmitter........................................................................................... Using the Internal Pump................................................................................................. Pump Valve Assembly Cleaning Instructions ................................................................. Using an External Pump................................................................................................. External Fluke Pressure Module Compatibility............................................................... Supplying Loop Power ................................................................................................... mA Modes ...................................................................................................................... i 1 2 5 8 8 8 9 10 10 10 15 15 17 18 18 719 Series Users Manual Sourcing 4 to 20 mA ...................................................................................................... Simulating a 4 to 20mA Transmitter............................................................................... Percent Error Setup ....................................................................................................... Maintenance .................................................................................................................. In Case of Difficulty ................................................................................................... Cleaning.................................................................................................................... Replacing the Batteries............................................................................................. Calibration ..................................................................................................................... Parts and Accessories ................................................................................................... Specifications ................................................................................................................ Pressure Sensor Input .............................................................................................. Pressure Module Input.............................................................................................. DC mA Measure and Source .................................................................................... Loop Supply .............................................................................................................. Pressure Source ....................................................................................................... General Specifications .............................................................................................. Contacting Fluke............................................................................................................ ii 19 19 21 21 21 21 22 22 23 26 26 26 26 26 26 27 27 List of Tables Table 1. 2. 3. 4. 5. 6. 7. Title Page Symbols................................................................................................................................. Front Panel Features............................................................................................................. Pushbutton Functions............................................................................................................ Pump Features...................................................................................................................... Recommended Pressure Modules ........................................................................................ Fluke Pressure Module Compatibility .................................................................................... Replacement Parts ................................................................................................................ iii 4 5 6 7 14 17 23 719 Series Users Manual iv List of Figures Figure 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Title Page Connection Technique .......................................................................................................... Front Panel Features............................................................................................................. Pump Features...................................................................................................................... Internal Pressure Sensor with Internal Pump ........................................................................ Pressure Module with Internal Pump..................................................................................... Pressure Module with External Pump ................................................................................... Sourcing Loop Voltage .......................................................................................................... Sourcing mA Connections ..................................................................................................... Connections for Simulating a 4 to 20 mA Transmitter ........................................................... Battery Replacement ............................................................................................................. Replacement Parts ................................................................................................................ v 4 5 7 12 13 16 18 19 20 22 25 719 Series Users Manual vi Introduction The Calibrator features: The 719 30G and 100G Series Pressure Calibrators (the Calibrator) perform the following functions: * Precision air bleed for fine control * Fine vernier adjustment for the pump * Calibrate P/I (pressure to current) transmitters * A serviceable electric pump * Calibrate I/P (current to pressure) devices * Pressure limit settings * Identify the set, reset and deadband of of pressure switches * HART resistor mode * Measure pressure via a 1/8-in. NPT pressure fitting and an internal pressure sensor or via a Fluke 700 Series Pressure Module The Calibrator ships with: * holster * Source pressure via electric pump * two installed 9 V alkaline batteries * Measure, source, and simulate current up to 24 mA * * TL75 test leads Simultaneously displays pressure and current * Supply loop voltage * AC70A alligator clips * Calculate mA percentage in Percent Mode * hose kit * Calculate mA error % in Percent Error Mode * Product Overview Manual * Switch between pressure/vacuum control * CD-ROM (Users Manual) 1 719 Series Users Manual The Calibrator makes 5-digit pressure measurements in the units shown below: * Psi * inH2O at 4 C * inH2O at 20 C * kPa * cmH2O at 4 C * cmH2O at 20 C * bar * mbar * kg/cm2 * inHg * mmHg For pressure modules, full-scale readings for all pressure ranges can be made in: * Psi * kPa * inHg To avoid display overflow, full scale readings are limited to 1000 psi in cmH2O, mbar, and mmHg units, and 3000 psi in inH2O units. Pressures of at least 15 psi must 2 be measured for meaningful readings in bar and kg/cm units. 2 Safety Information A Warning identifies conditions and actions that pose hazard(s) to the user; a Caution identifies conditions and actions that may damage the Calibrator or the equipment under test. Symbols used in this manual and on the Calibrator are listed in Table 1. XWWarning To avoid possible electric shock or personal injury: * Use the Calibrator only as specified in this manual, otherwise the protection provided by the Calibrator may be impaired. * Never apply more than 30 V, including transients, between the mA terminals, or between either of the mA terminals and earth ground. * The Calibrator is rated for CAT I measurement only. Do not use the Calibrator to make measurements in a CAT II, CAT III, or CAT IV environments. CAT I equipment is designed to protect against transient from high-voltage, lowenergy sources, such as electronic circuits or a copy machine * Remove the test leads from the Calibrator before opening the battery door. Pressure Calibrator with Electric Pump Introduction * * * * * * * * * * * Make sure the battery door is closed and latched before operating the Calibrator. Do not operate the Calibrator if it is damaged. Do not operate the Calibrator around explosive gas, vapor, or dust. When using probes, keep fingers behind the finger guards on the probes. Use only two 9 V batteries, properly installed in the Calibrator case, to power the Calibrator. Follow all equipment safety procedures. Turn off circuit power before connecting the Calibrator mA and COM terminals in the circuit. Place Calibrator in series with the circuit. When servicing the Calibrator, use only specified replacement parts. Do not allow water inside the case. To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator (B) appears. To avoid a violent release of pressure in a pressurized system, shut off the valve and slowly bleed off the pressure before attaching or detaching the internal pressure sensor or pressure module fitting to the pressure line. * * * * * * To avoid over pressure damages, do not apply pressure that exceeds the limits listed in the Pressure Specifications table in the Specifications section. To avoid mechanically damaging the Calibrator, do not apply torque between the pressure fitting and the Calibrator case. See Figure 1 for the proper use of tools. To avoid misleading readings, disconnect the pressure module connector at the Calibrator. To avoid damage to the pressure module, refer to the related Instruction Sheet. To avoid damage to the pump, use with dry air and non-corrosive gases only. Check test leads for continuity before using. Inspect Calibrator for cracks or damage, do not use the probes if they are damaged or show high resistance. 3 719 Series Users Manual Table 1. Symbols Symbol J fgx001f.eps Figure 1. Connection Technique 4 Earth ground M Battery W Caution: Important information. Refer to instruction sheet X T Hold in fixed position Meaning Hazardous voltage. Risk of electric shock. Double insulated ) Conforms to relevant Canadian Standards Association directives. P Conforms to European Union requirements f Pressure ~ Do not dispose of this product as unsorted municipal waste. Go to Fluke's website for recycling information. ; Conforms to relevant Australian standards. Pressure Calibrator with Electric Pump Getting Acquainted with the Calibrator Getting Acquainted with the Calibrator The Calibrator displays pressure and current measurements simultaneously. See Table 2 and Figure 2 for front panel features. The upper display shows the applied pressure or vacuum (shown as a negative value). Press ENTER then UNITS to select a different unit. When the power is cycled off and on, the Calibrator retains the unit last selected. The lower section of the display shows the current (up to 24 mA) applied to the current (mA) inputs, or the mA output value. 1 719 RE SSU TOR PRE LIBRA CA HOLD P LOOWER PO 2 ER O ENT ZER S UNIT MINAX M mA UT OUTP mA P 6 L. ST AL ADJU ITCH SWTE ST HOLD UMP 25% Step ITS LIM 30VAX M To source loop voltage, press Z while pressing O ON. Pushbutton operation is described in Table 3. Pump features are shown in Figure 3 and described in Table 4. COM TE ULA /SIM RCE 24 mA 0- SOU -7 34.5 5 Table 2. Front Panel Features Item Feature A Pressure Measurement B Pressure Module Input C Current Terminals D Pressure Sensor Input (install filter here) E Power Button F Current mA Measurement and Source 4 3 Fgx005f.eps Figure 2. Front Panel Features 5 719 Series Users Manual Table 3. Pushbutton Functions Pushbutton Z UNITS Description Press to zero the pressure display. Vent pressure to atmosphere before pressing. With an Absolute Pressure Module, see special instructions below. Press C then UNITS to change pressure units. Continue to press UNITS for next selection or use U to move back or V to move forward. Press ENTER when finished or await timeout. All units are available when the pressure sensor input is used. For higher pressure module inputs, out-of-range units are not available. Press OON while pressing Zto source loop voltage. N Press to read the minimum pressure and current readings since power was turned on or the registers were cleared. Press again to read the maximum pressure and current readings since power was turned on. Press and hold for 3 seconds to clear the MIN/MAX registers. Us as the up arrow in select functions. S Press to perform switch test. Used as a down arrow in select functions. U V mA OUTPUT A h 25% Step C ENTER P LIMITS 6 Press to toggle the mA display mode between mA, mA Percent, mA Percent Error, mA source and mA simulate. Press h to freeze the display. g appears on the display. Press h again to resume normal operation. When in mA source mode, press to step output in 25 % intervals of full scale (20 mA). Press to enter or shift to units and limits functions. Press again to return to normal operation. Press to activate pump and source pressure/vacuum. Press C then LIMITS to set maximum pressure limit. Pressure Calibrator with Electric Pump Getting Acquainted with the Calibrator Table 4. Pump Features Item A Description MINAX M mA UT OUTP mA Internal Pump- Press P to activate internal electric pump and source pressure/vacuum. L. ST AL ADJU ITCH SWTE ST P PUM 25% Step ITS LIM 30VAX M B Pressure Vacuum Switch- Rotate forward (clockwise) for pressure, backward (counterclockwise) for vacuum. C Pressure/Vacuum Release Valve- Rotate fully backward (counter-clockwise) to release all pressure or vacuum. (Rotate slightly for partial release.) Rotate fully forward (clockwise) to close valve. D Fine Adjustment Knob-Rotate either direction for precise adjustment of applied pressure or vacuum. Full rotation is about 30 turns. COMTE ULA /SIM RCE 24 mA 0- SOU 1 2 3 4 fgx009f.eps Figure 3. Pump Features 7 719 Series Users Manual HART Resistor The Calibrator has a selectable 250 HART resistor to facilitate use with HART communication devices. Use a HART communicator when measuring mA with loop power or sourcing mA. The HART resistor defaults to OFF. Switch Test To perform a switch test: To turn on the HART resistor: 1. With the Calibrator OFF, press O. 2. When HArt is displayed, press Vor U to turn on/off. 1. Power Saver The Calibrator automatically turns off after 30 minutes of inactivity. To reduce this time or disable this feature: 1. With the Calibrator OFF, press O. 2. P.S. xx is displayed, where xx is the turn-off time in minutes. OFF means the power saver is disabled. 3. Press Vor U to decrease or increase the turn-off time. 4. To disable, press Vuntil the display shows OFF. The Calibrator resumes normal operation after 2 seconds. 8 2. Note This example uses a normally closed switch. The procedure is the same for an open switch but the display reads OPEN instead of CLOSE. Connect the Calibrator mA and COM terminals to the switch using the pressure switch terminals and connect an external pump between the Calibrator and the pressure switch. The polarity of the terminals does not matter. Note If using an external pump, connect the pump to the Calibrator and to the input of the switch using a tee fitting. Make sure the vent on the pump is open and zero the Calibrator if necessary. Close the vent after zeroing the Calibrator. Pressure Calibrator with Electric Pump Zeroing with Absolute Pressure Modules 3. 4. 5. 6. Press S to enter pressure switch test mode. The Calibrator will display CLOSE instead of a mA measurement. Apply pressure with the pump slowly until the switch opens. Note In the switch test mode, the display update rate is increased to help capture changing pressure inputs. Even with the enhanced sample rate, pressuring the device under test should be done slowly to ensure accurate readings. OPEN is displayed once the switch is open. Bleed the pump slowly until the pressure switch closes. RCL appears on the display. Zeroing with Absolute Pressure Modules For zeroing, adjust the Calibrator to read a known pressure. This can be barometric pressure, if it is accurately known, for all but the 700PA3 module. An accurate pressure standard can also apply a pressure within range for any Absolute Pressure Module. Adjust the Calibrator reading as follows: 1. Press and hold Z. 2. Press Z to increase or Y to decrease the Calibrator reading to equal the applied pressure. 3. Release Z to exit the zeroing procedure. Press S to read the pressure values for when the switch opened, for when it closed, and for the deadband Hold S for 3 seconds to reset Switch Test mode; press any other key to exit. 9 719 Series Users Manual Set Maximum Pressure Limit Using the Internal Pump To set a maximum pressure limit for the internal electric pump: The internal pump can provide the rated pressure for the Calibrators. 1. Press C then LIMITS and the limit setting is displayed. 2. Use Z to increase or Y the limit setting. The preferred use for the internal pump is shown in Figure 4, where the Calibrator displays pressure measured with the internal sensor and provided by the internal pump. 3. Press ENTER when finished. When the calibrator power is cycled, the limit setting is retained. Note To prevent pressure module damage, operation of the internal electric pump is automatically limited to the maximum rating of the module. For 1 inH2O, 10 inH2O and 1 psi modules, the internal pump is disabled. Calibrating a P/I Transmitter To calibrate a P/I (pressure to current) transmitter, apply a pressure to the transmitter and measure the transmitter's current loop output. Pressure can be applied with the Calibrator's internal pump or with an external pump. W Warning To avoid a violent release of pressure or vacuum, always depressurize the system slowly using the pressure/vacuum release control before detaching any pressure line. 10 The internal pump can also be used with certain Fluke 700 Series Pressure Modules. In this case, pressure measured by the Pressure Module is displayed by the Calibrator. Appropriate pressure modules for each Calibrator model are identified in Table 5. Figure 5 shows the internal pump being used with a pressure module. Note If both a pressure module and the internal sensor are connected, the Calibrator displays ONLY the pressure module measurement. Pressure Calibrator with Electric Pump Using the Internal Pump To use the Calibrator's internal pump, refer to Figure 3 and perform the following steps: 1. Depressurize and drain the line before connecting the Calibrator. 2. Connect the pressure transmitter to the Calibrator internal sensor as shown in Figure 4 (for internal pressure sensor measurements) or Figure 5 (for pressure module measurements). 3. 4. Note To avoid leaks, use Teflon tape or similar sealant on all pressure connections. Make sure the pressure/vacuum switch is in the desired position. Forward (clockwise) is for pressure; backward (counter-clockwise) is for vacuum. 5. Press Zto zero the pressure display. 6. Turn the fine adjustment knob to mid-range. 7. Turn the pressure/vacuum release control forward (clockwise) to close the release valve. 8. Press P to apply pressure/vacuum. 9. Note This knob adjusts a small internal reservoir to vary the total volume. With larger external pressure/vacuum volumes, this control will adjust pressure or vacuum within a smaller range. Depressurize the system before disconnecting the pressure line. Turn the pressure/vacuum release control backward (counter-clockwise) to vent pressure/vacuum from the pump. 11 719 Series Users Manual 719 RE SSU TOR PRE LIBRA CA Black HOLD P LOOWER PO Red ER O ENT ZER S UNIT MINAX M mA UT OUTP mA L. ST AL ADJU ITCH SWTE ST HOLD P PUM 25% Step mA ITS LIM 30VAX M COMTE ULA /SIM RCE 24 mA 0- S I G N A L SOU + - T E S T fgx002f.eps Figure 4. Internal Pressure Sensor with Internal Pump 12 Pressure Calibrator with Electric Pump Using the Internal Pump S I G N A L Pressure Module + - T E S T 719 RE SSU TOR PRE LIBRA CA HOLD P LOOWER PO ER O ENT ZER S UNIT MINAX M mA UT OUTP mA L. ST AL ADJU HOLD P PUM 25% Step f mA ITS LIM V 30VA 30 MAXX M COMTE ULA /SIM RCE 24 mA 0- SOU -7 Red Black fgx010f.eps Figure 5. Pressure Module with Internal Pump 13 719 Series Users Manual Table 5. Recommended Pressure Modules Pressure Module 700 P00 700 P01 700 P02 700 P22 700 P03 700 P23 700 P04 700 P24 700 P05 700 P06 700 P27 700 P07 700 P08 700 P09 700 PA3 700 PA4 700 PA5 14 External Pump 719 30G/100G X X X X X X X X X X X X X X X X X Internal Pump 719 30G 719 100G X X X X X X X X X X X X X X X X X X X X X Pressure Module 700 PA6 700 PV3 700 PV4 700 PD2 700 PD3 700 PD4 700 PD5 700 PD6 700 PD7 700 P29 700 P30 700 P31 External Pump 719 30G/100G X X X X X X X X X X X X Internal Pump 719 30G 719 100G X X X X X X X X X X X X X X Pressure Calibrator with Electric Pump Pump Valve Assembly Cleaning Instructions Pump Valve Assembly Cleaning Instructions 9. 1. Using a small screwdriver, remove the two valve retention caps located in the oval shaped opening on the underside of the Calibrator. 10. Seal the output of the Calibrator and pump up the unit to at least 50 % its rated pressure. 2. After the caps have been removed, gently remove the spring and o-ring assembly. 3. Set aside the valve assemblies in a safe area and clean out the valve body using a cotton swab soaked in IPA (isopropyl alcohol). 4. Repeat this process several times using a new cotton swab each time until there is no remaining sign of residue. 5. Run pump for a few seconds. 6. Clean the o-ring assembly and o-ring on the retention caps with IPA and inspect the o-rings closely for any cuts, nicks, or wear. Replace if needed. 7. 8. Inspect the springs for wear or loss of tension. They should be approximately 8.6 mm long in the relaxed state. If they are shorter than this, they may not allow the o-ring to seat properly. Replace if needed. Once all parts have been cleaned and inspected, reinstall the o-ring and spring assemblies into the valve body. Reinstall the retention caps and gently tighten the cap. 11. Release the pressure and repeat several times to ensure that the o-rings seat properly. The Calibrator is now ready for use. Using an External Pump W Caution To avoid damage to the Calibrator and possible release of pressure, do not connect the internal sensor to an external pressure source that exceeds the maximum rated pressure. To develop higher pressure or vacuum, use an external pump (such as the Fluke Model 700PTP). Use a Fluke Pressure Module connected to the pressure module input on the Calibrator. Pressure modules are listed in Table 5. Make overall connections as shown in Figure 6. Refer to setup and operating instructions included with the pressure module and pump. 15 719 Series Users Manual S I G N A L Pressure Module + - 719 RE SSU TOR PRE LIBRA CA HOLD T E S T P LOOWER PO ER O ENT ZER S UNIT MINAX M mA L. ST AL ADJU ITCH SWTE ST P PUM 25% Step f mA ITS LIM 30VAX M COM TE ULA /SIM RCE 24 mA 0- SOU Red Black fgx006f.eps Figure 6. Pressure Module with External Pump 16 Pressure Calibrator with Electric Pump External Fluke Pressure Module Compatibility External Fluke Pressure Module Compatibility If inappropriate units are selected, the output of Fluke 700P Pressure Modules can cause the Calibrator display to overflow (OL), or displays values that are too low to be read. Refer to Table 6 for appropriate unit and range compatibility. Table 6. Fluke Pressure Module Compatibility Pressure Unit Module Compatibility psi Available on all pressure ranges inH20 All ranges through 3000 psi cmH20 All ranges through 1000 psi bar 15 psi and above mbar All ranges through 1000 psi kPa Available on all pressure ranges inHg Available on all pressure ranges mmHg kg/cm 2 All ranges through 1000 psi 15 psi and above 17 719 Series Users Manual Supplying Loop Power mA Modes The Calibrator can supply loop power at 24 V dc to a current transmitter that is disconnected from the system. Use the following procedure: Different mA functions can be accessed by repeatedly pressing A: 1. With power off, hold down Z while pressing n. Loop Power appears in the display. 2. With the transmitter disconnected from normal loop power, connect the Calibrator mA (+) and COM (-) test leads in series with the instrument current loop as shown in Figure 7. 3. Measure loop current in the mA display. 4. Press n off to deactivate the 24 V dc supply when finished sourcing loop voltage. - T E S T qo007f.eps Figure 7. Sourcing Loop Voltage 18 mA- measured current is displayed. * Percent Mode- current is displayed as a percentage based on a 4-20 mA scale. * Percent Error Mode- transmitter current output error is displayed. Error is calculated based on a configurable zero and span pressure and a 4-20 mA scale. * mA Source- Outputs current displayed. Use Vor U to adjust current setting. * mA Simulate- Sets current when using an external 24 V loop power supply. Use Vor U to adjust the current setting. Note Display flashes OL if there is an open circuit in source or simulate mode. S I G N A L + * Pressure Calibrator with Electric Pump Sourcing 4 to 20 mA Sourcing 4 to 20 mA Simulating a 4 to 20mA Transmitter To select current-sourcing mode, use the following procedure: Simulate is a mode of operation in which the calibrator is connected into a loop in place of a transmitter and supplies a known, settable test current. 1. Press A until Source is displayed. 2. Connect leads as shown in Figure 8. 3. Enter the desired current by pressing Z or Y. 1. Connect the 24 V loop power source as shown in Figure 9. 2. Press A until Simulate is displayed. 3. Enter the desired current by pressing Z or Y. Red + - Black Common fgx012.eps Figure 8. Sourcing mA Connections 19 719 Series Users Manual 719 PRESSURE CALIBRATOR Red + Loop Power Supply +24 V Black Readout or Controller - fgx011.eps Figure 9. Connections for Simulating a 4 to 20 mA Transmitter 20 Pressure Calibrator with Electric Pump Percent Error Setup Percent Error Setup In Case of Difficulty 1. Press and hold A. After 3 seconds the set icon and 0% appears on the lower display. * 2. Use Vand U to adjust the % point for the Percent Error calculation, then press ENTER to confirm selection. Check the battery, test leads, pressure module, and pressure tubing. Follow replacement and connection instructions properly. * Review this manual to make sure the Calibrator is used correctly. 3. Press a. 100% is displayed on the lower display. Cleaning 4. Use Vand U to adjust the 100% point for the Percent Error calculation. 5. Press ENTER to confirm the selection and to exit. Maintenance XWWarning To avoid possible electric shock, personal injury, or sudden release of pressure, review Safety Information before proceeding. Remove test leads before opening. WCaution To avoid damaging the Calibrator, do not use aromatic hydrocarbon or chlorinated solvents for cleaning. These solutions will react with and damage the plastics used in the Calibrator. Periodically wipe the case with a damp cloth and detergent; do not use abrasives or solvents. For maintenance procedures not described in this manual, or if the Calibrator needs repair, contact a Fluke Service Center. See Contacting Fluke. 21 719 Series Users Manual Replacing the Batteries When the battery symbol (B) appears, replace the two 9 V alkaline batteries. Refer to Figure 10. XW Warning To avoid false readings, which could lead to possible electric shock or personal injury, replace the batteries as soon as the battery indicator (B ) appears. Remove test leads before changing the battery. Calibration Fluke recommends calibrating the Calibrator once a year to ensure that it performs according to its specifications. wh008f.eps Figure 10. Battery Replacement 22 Pressure Calibrator with Electric Pump Parts and Accessories Parts and Accessories Refer to Table 7 and Figure 11. Table 7. Replacement Parts Item Description Part/ Mod. No. Qty Alligator clip red 1670641 1 Alligator clip black 1670652 1 BT1, BT2 9 V battery, ANSI/NEDA 1604A or IEC 6LR61 614487 2 Holster Holster, Yellow 664182 1 H2, 3, 4 Case screw 832246 3 H5, 6 Battery door fasteners 948609 2 H7, 8 Bracket screw 641131 2 MP1 LCD bezel, 719 30G 3315359 1 MP1 LCD bezel, 719 100G 3322203 1 MP2 LCD, 719 3345775 1 MP3, 4 Pump retainer bracket kit, 719 3345782 2 MP5 Gasket 664208 1 MP6 Pump and vernier (no motor), 719 3345794 1 MP7, 8 Selector knob 3330278 2 AC72 23 719 Series Users Manual Item Description Part/ Mod. No. Qty MP9 Vernier adjust knob 664190 1 MP11, 12, 13 O-ring 146688 3 MP14 Spacer 687449 1 MP85 Case top/connector 3315431 1 MP86 Case bottom 3315686 1 MP89, 90 Non-skid foot 885884 2 MP92 Battery door 664177 1 S1 Keypad 3315673 1 TL20 Industrial test lead set 1639457 Opt TL75 Test lead set 855742 1 TM1 719 Product Overview Manual 3316579 1 - Electric motor, 719 3345802 1 CD-ROM 719 CD-ROM (contains Users Manual) 3316449 1 - 71X Series Calibration Manual 686540 Opt - Pump (with cleanout) rebuild kit, 719 3345816 Opt - 719 30G Top Case Decal 2547000 1 - 719 100G Top Case Decal 2547017 1 - Hose kit 3345825 Opt 24 Pressure Calibrator with Electric Pump Parts and Accessories MP85 MP1 Holster AC72 Alligator Clips MP2 S1 MP5 TM1 TL75 Test Lead Set MP14 MP11,12,13 H7,8 MP7 MP3,4 MP8 MP6 MP86 BT1 BT2 MP92 MP9 H5,6 H2,3,4 CD-ROM MP89,90 fgx004f.eps Figure 11. Replacement Parts 25 719 Series Users Manual Specifications Specifications are based on a one year calibration cycle and apply for ambient temperature from +18 C to +28 C unless stated otherwise. Counts are the number of increments or decrements of the least significant digit. Pressure Sensor Input Model 30G 100G Range DC mA Measure and Source Accuracy -12 to 36.0 psi 0.025 % of Range (6 month calibration) -12 to 120.0 psi 0.035 % of Range (1 year calibration) Max Nondestructive Pressure 60 psi (determined by Pressure Module) 26 0.001 mA 0.015 + 2 Fuseless overload protection 200 psi Temperature coefficient: 0.005 % of range per C for temperature ranges -10 C to 18 C and 28 C to 55 C Loop Supply 24 V dc nominal Pressure Source Pressure Module Input Resolution 24 mA Accuracy (% of Reading + Counts) Resolution Maximum load on mA source is 1000 . With HART resistor on, maximum load is 750 . Temperature coefficient: 0.01 % of range per C for temperature ranges -10 C to 18 C and 28 C to 55 C Range Range Model Accuracy Range 30G -11 to 36.0 psi 100G -11 to 120.0 psi Pressure Calibrator with Electric Pump Contacting Fluke General Specifications Maximum voltage applied between either mA terminal and earth ground or between the mA terminals: 30 V Storage temperature: -30 C to 60 C Operating temperature: -10 C to 55 C Operating altitude: 3000 m maximum Relative humidity: 95 % up to 30 C, 75 % up to 40 C, 45 % up to 50 C, and 35 % up to 55 C Vibration: Random 2 g, 5 Hz to 500 Hz per MIL-PRF28800F Class 2 Calibration Cycle: 6 months to 2 years based on desired accuracy. Contacting Fluke To contact Fluke for product information, operating assistance, service, or to get the location of the nearest Fluke distributor or service center, call: 1-888-44-FLUKE (1-888-443-5853) in U.S.A 1-800-36-FLUKE in Canada +31-402-675-200 in Europe +81-3-3434-0181 Japan +65-738-5655 Singapore +1-425-446-5500 from other countries Shock: 1 m drop test, per IEC 61010-1 Or visit Fluke's website at: www.fluke.com. Protection Class: Pollution Degree II Register the Calibrator at: http://register.fluke.com. Safety: Address correspondence to: * Complies with EN/IEC61010-1 2nd ed. * Agency Approvals: CSA-C22.2 No. 61010-1-04 Power requirements: Two 9 V batteries (ANSI/NEDA 1604A or IEC 6LR61) Fluke Corporation P.O. Box 9090, Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186, 5602 BD Eindhoven Size: 60 mm H x 87 mm W x 210 mm L (2.38 in H x 3.41 in W x 8.28 in L); with holster: 66 mm H x 94 mm W x 216 mm L (2.61 in H x 3.72 in W x 8.5 in L) Weight with Holster: 912 g (2.00 lb) 27 719 Series Users Manual 28 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Fluke: FLUKE-719 30G FLUKE-719 100G