Detailed specifications
TiR125 TiR110 TiR105 Ti100
Building diagnostics General use
IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
Spectral band 7.5 μm to 14 μm (long wave)
Capture or refresh rate 9 Hz
NETD (Thermal sensitivity) ≤ 0.08 °C at 30 °C target temp (80 mK) ≤ 0.10 °C at 30 °C target temp
(100 mK)
FOV (Field of view) 22.5 °H x 31 °V
IFOV (Spatial resolution) 3.39 mRad
Temperature measurement range
(not calibrated below -10 °C)
-20 °C to +150 °C
(-4 °F to +302 °F)
-20 °C to + 250 °C
(-4 °F to 482 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanism IR-OptiFlex™ focus system Focus-free 1.2 m (4 ft) and beyond
IR-Fusion® technology PIP, FULL IR, FULL VISIBLE,
AutoBlend™PIP, FULL IR, FULL VISIBLE
PIP (1.2 m (4 ft)
to 4.6 m (15 ft)), FULL IR,
FULL VISIBLE
No, full IR only
Color alarms
High termperature, low
temperature (dewpoint), and
isotherm
Low temperature (dewpoint) —
Standard palettes Blue-Red, Grayscale, Inverted Grayscale, High-contrast,
Hot Metal, Ironbow, Amber, Inverted Amber
Blue-Red, Ironbow, Grayscale,
Amber
Ultra Contrast™ palettes
Blue-Red, Grayscale, Inverted
Grayscale, High-contrast,
Hot Metal, Ironbow, Amber,
Inverted Amber
Blue-Red, Grayscale, Ironbow —
Hot/cold markers Yes —
User definable spot markers Three on camera and in SmartView®in SmartView® only
Centerpoint Yes
Centerbox (MIN/AVG/MAX) Yes —
Level and span control Manual and auto
Minimum span in auto mode 2.5 °C 5 °C
Minimum span in manual mode 2.0 °C 2.5 °C
Minimum IR focus distance 15.25 cm (6 in) 122 cm (48 in)
Weight 0.726 kg (1.6 lb)
Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal (portrait format)
Visible camera 2 megapixel industrial-grade N/A
Minimum parallax ~45.7 – 55.9 cm (~ 18 in – 22 in) ~122 cm (48 in) N/A
IR-PhotoNotes™ annotation system Yes (3 images) —
Laser pointer Yes
Torch Yes —
Electronic (cardinal) compass Yes —
Emissivity correction Yes
Transmission correction Yes —
Background (reflected) compensation Yes
Voice annotation (audio) Yes (60 seconds) per image —
Multi-mode video output Streaming USB video output —
Multi-mode video recording
(standard AVI with MPEG encoding) Yes (AVI with MPEG encoding) —
Multi-mode video recording
(radiometric .is3)
Yes, radiometric .is3 for
approx. 2.5 to 5 minutes de-
pending upon thermal scene
—
Memory review thumbnail review
Battery (field-replaceable,
rechargeable) Two One
Battery life 4+ hours (each)*
External battery charging base Included Optional (accessory)
Charging power supply Yes
*Assumes 50% brightness of LCD
2 Fluke Corporation TiR125, TiR110, TiR105 Building Diagnostic and Ti100 General Use Thermal Imagers