HWS Series
3055 Del Sol Blvd • San Diego, CA 92154 • 1-800-LAMBDA-4 41
Limited Lifetime Warranty Lower Cost of Ownership
High Efficiency Easier System Cooling
Wide Range AC Input Supports Global Use
Feature Benefit
Limited Lifetime Warranty
UL508 approved
SEMI F47 Compliant (high line AC)
Universal Input (85 - 265VAC)
High Efficiency
HWS Features and Benefits
MODELS HWS15 HWS30 HWS50 HWS100 HWS150
ITEMS
Input Voltage range - 85 - 265VAC (47 - 63Hz) or 120 - 370VDC
Input Current (Typ) (1) A 0.4 / 0.2 0.8 / 0.4 0.7 / 0.35 1.3 / 0.65 1.9 / 0.95
Inrush Current (1) A 14 / 28
Power Factor - Meets EN61000-3-2
Temperature Coefficient - <0.02%/°C
Overcurrent Protection - >104%
Overvoltage Protection V Yes (See page 2)
Hold Up Time (Typ) ms 20
Leakage Current (max) mA <0.5mA (Typ 0.3mA at 100VAC, 0.5mA at 230VAC)
Remote Sense - No Yes
Indicator - Green LED = ON
Operating Temperature (no cover) - -10C to +70C, derate linearly to 20% load from 50°C to 70°C(2)
Storage Temperature - -30 to +85°C
Humidity (non condensing) - Operating: 30 - 90%RH, Non operating 10 - 95%RH
Cooling - Convection
Withstand Voltage - Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance - >100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s2constant X, Y, Z 1 hour
Shock - < 196.1m/s2
Safety Agency Certifications - UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark(3)
Line Dip - Complies with SEMI F47 (200VAC line only)
Conducted & Radiated EMI EN55011 / EN55022-B, FCC-B, VCCI-B
Recommended EMI Filter -
Immunity - IEC61000-4-2 (Level 3,2), -3, -4, -5, -6 (Level 3), -8, -11 (Level 4)
Weight (Typ) g 180 220 280 450 500
Size (WxHxD) in 1.04x3.23x3.15 1.04x3.23x3.74 1.04x3.23x4.72 1.1x3.23x6.3 1.46x3.23x6.3
Size (WxHxD) /A version 1.24x3.23x3.15 1.24x3.23x3.74 1.24x3.23x4.72 1.3x3.23x6.3 1.65x3.23x6.3
Warranty - Limited lifetime warranty (See Lambda’s terms & conditions)
Single Output Industrial Power Supplies
Specifications
(1) 100/200VAC
(2) -40°C Start up, see options table
(3) UL60601-1, EN60601-1, see options table
Factory Automation Process Control, NC-Machining,
Automotive, Packaging Equipment,
Materials Handling,
Chemical Processing, Robots
Test & Measurement Burn-in & Test, Automated
Test, Instrumentation,
Measurement, Detection
Automated Service
Key Market Segments & Applications