METAL OXIDE VARISTORS TNRTM
CAT. No. E1006Q
?GENERAL SPECIFICATIONS
?RELIABILITY CHARACTERISTICS
Test Conditions Specifications
Item
Standard Test
Condition
Varistor Voltage
Maximum Allowable
Voltage
Maximum Peak
Surge Current
Energy Rating
Rated Wattage
Maximum Clamping
Voltage
Capacitance
Voltage Temperature
Coefficient
Insulation
20P5C, 65P20
%RH
unless specified.
However, if it does not affect test result,
the condition can be 20P15C, 65P20
%RH
also.
The voltage between the two terminals measured at 1mA DC is called Varistor Voltage.
The measurement shall be made as fast as possible to avoid heat affection.
Maximum continuous AC voltage (50 to 60Hz/AC) and maximum DC voltage which can be
applied.
Maximum surge current (8/20Ms pulse wave to be applied once, or twice, 2 minutes apart) for
varistor voltage change within P10% of the initial value.
Maximum energy (2ms square wave to be applied once) for varistor voltage change within
P10% of the initial value.
Maximum power (50 to 60Hz/AC power to be applied for 1,000 hours at 85P2C) for varistor
voltage change within P10% of the initial value.
Maximum voltage across varistor when 8/20Ms rated current surge is applied.
Varistor's capacitance at 1kHz, standard test condition.
V1mA : Actual Varistor Voltage
Short circuit the two leads of varistor, and put the varistor body into lead balls (1.6mm
diameter) leaving 2mm epoxy coating outside. Then, apply 2.5kVrms between the leads and
the lead balls for 60P5 sec..
Satisfy the specification
Satisfy the specification
Satisfy the specification
Satisfy the specification
Satisfy the specification
Satisfy the specification
For reference only.
Within P0.05%/C
The varistor shall withstand
with no abnormality.
V1mA at 85C – V1mA at 25C1
V1mA at 25C60 B100 (%/C)
B
Test Conditions Specifications
Item
Heat Cycle
High Temperature
Exposure
Damp Heat
(Humidity)
High Temperature
Operation
Subject varistor to the following temperature cycles. -40C for 30 minutes Normal room
temperature for 10 minutes 85C for 30 minutes Normal room temperature for 10 minutes.
This completes one cycle. The cycle shall be repeated 100 times total. After the cycles, the
varistor shall be stored at normal room temperature for one hour. Then check the varistor
voltage and the appearance.
Store varistor at 125C for 1,000 hours. After that, store the varistor at normal room
temperature for one hour. Then check the varistor voltage.
Store at 40C, 90 to 95
%RH
for 1,000 hours. After that, store the varistor at normal room
temperature for one hour. Then cheek the varistor voltage.
Apply maximum applied voltage to varistor at 85C for 1,000 hours. After that, store the varistor
at normal room temperature for one hour. Then check the varistor voltage.
DV1mA [P5%
No appearance abnormality.
DV1mA [P5%
DV1mA [P5%
DV1mA [P10%
Operating Temperature Range: -40 to +85C
Storage Temperature Range: -50 to +125C
(4/5)