All dimensions are in inches and metric. All specifications are to the latest revisions. Specifications are subject to change without notice.
Registered trademarks are the property of their respective companies. Made in USA
5/21/02 SY/EH/LS PomonaACCESS 90111 (800) 444-6785 or (425) 446-6010
Last saved by PN More drawings available at www.pomonaelectronics.com
S:\Engineering\Release\DataSheets\FlukeDataSheet\d_AI_5218_2_03.doc Page 2 of 2
Model 5218 & Assembly Instructions
Triaxial Male 3 Lung Connector To Cable
Sales: 800-490-2361 Fax: 888-403-3360
Technical Assistance: 800-241-2060
FIGURE #1
Slide clamp nut, flat washer and Vee gasket over cable.
Strip outer jacket or cable.
FIGURE #2
Comb braid forward.
Slide braid clamp over braid and against outer cable jacket. Fold braid back over braid clamp, trim even with base of
braid clamp.
Assemble retainer and insulator over inner jacket.
Trim inner jacket.
FIGURE #3
Place small braid clamp over inner braid and against inner jacket, comb out inner braid and fold inner braid back over
small braid clamp, trim inner braid even with base of small braid clamp.
Assemble washer over dielectric again inner braid.
Trim inner dielectric and center conductor.
FIGURE #4 Solder center contact to center conductor.
Place inner insulator, outer contact and outer insulator over center contact and insert into body.
Slide clamp nut, washer and Vee gasket forward, thread assembly into body and tighten.
FIGURE #5
Completed assembly shown.