https://www.phoenixcontact.com/us/products/1530249
08/29/2014Page1/4
Bus system cable-SAC-2P-M12MSB/ 6,0-910/M12FSB-1530249
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Bus system cable, PROFIBUS, 2-position, PUR halogen-free, Violet, RAL 4001, shielded, Plug straight M12, B-
coded, on Socket straight M12, B-coded, Cable length: 6 m
Key commercial data
Packing unit 1 pc
Weight per Piece (excluding packing) 422.4 GRM
Custom tariff number 85444290
Country of origin Poland
Technical data
Dimensions
Length of cable 6 m
Ambient conditions
Degree of protection IP65
IP67
IP68
General
Rated current at 40°C 4 A
Rated voltage 250 V
Number of positions 2
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Coding B - inverse
Signal type/category PROFIBUS
Status display No
Surge voltage category II
https://www.phoenixcontact.com/us/products/1530249
08/29/2014Page2/4
Bus system cable-SAC-2P-M12MSB/ 6,0-910/M12FSB-1530249
Technical data
General
Pollution degree 3
Insertion/withdrawal cycles ≥ 100
Material
Inflammability class according to UL 94 V0
Contact material CuSn
Contact surface material Ni/Au
Contact carrier material PA 66
Material of grip body TPU, hardly inflammable, self-extinguishing
Material, knurls Zinc die-cast, nickel-plated
Sealing material NBR
Cable
Cable type PROFIBUS
Cable type (abbreviation) 910
UL AWM style 21198 (80°C/300 V)
Conductor cross section 2x 0.25 mm² (signal line)
AWG signal line 24
Conductor structure signal line 19x 0.13 mm
Core diameter including insulation 2.55 mm ±0.07 mm
Wire colors Red, green
Overall twist 2 cores with 2 fillers to the core
Shielding Plastic-coated aluminum foil, tinned copper braided shield
Optical shield covering 85 %
External sheath, color Violet, RAL 4001
External cable diameter D 7.8 mm ±0.2 mm
Number of bending cycles 4000000
Bending radius 65 mm
Traversing path 4.5 m
Traversing rate 3 m/s
Acceleration 3 m/s²
Max. bending cycles 5000000
Bending radius 80 mm
Traversing path 4.5 m
Traversing rate 3 m/s
Acceleration 3 m/s²
Outer sheath, material PUR
Material conductor insulation Foamed PE
https://www.phoenixcontact.com/us/products/1530249
08/29/2014Page3/4
Bus system cable-SAC-2P-M12MSB/ 6,0-910/M12FSB-1530249
Technical data
Cable
Conductor material Tin-plated Cu litz wires
Insulation resistance ≥ 5 GΩ*km
Conductor resistance 157.2 Ω/km
Working capacitance 30 nF
Wave impedance nom. 150 Ω ±10 % (3 MHz ... 20 MHz)
Shield attenuation ≤ 4.9 dB (at 16 MHz)
Nominal voltage, cable 30 V
Test voltage Core/Core 1500 V (50 Hz, 1 min.)
Test voltage Core/Shield 1500 V (50 Hz, 1 min.)
Flame resistance UL 1581, Sec. 1060 (FT-1)
IEC 60332-1
Other resistance Low adhesion
Ambient temperature (operation) -40 °C ... 80 °C (cable, fixed installation)
-30 °C ... 70 °C (cable, flexible installation)
Classifications
eCl@ss
eCl@ss 4.0 27060306
eCl@ss 4.1 27060306
eCl@ss 5.0 27061801
eCl@ss 5.1 27061801
eCl@ss 6.0 27061801
eCl@ss 7.0 27061801
eCl@ss 8.0 27061801
ETIM
ETIM 2.0 EC000830
ETIM 3.0 EC001855
ETIM 4.0 EC001855
ETIM 5.0 EC001855
UNSPSC
UNSPSC 6.01 31251501
UNSPSC 7.0901 31251501
UNSPSC 11 31251501
UNSPSC 12.01 31251501
UNSPSC 13.2 31251501
https://www.phoenixcontact.com/us/products/1530249
08/29/2014Page4/4
Bus system cable-SAC-2P-M12MSB/ 6,0-910/M12FSB-1530249
Drawings
Schematic diagram
4 3
1 2
5
Pin assignment M12 male connector, 5-pos., B-coded, male side
Schematic diagram
3 4
2 1
5
Pin assignment M12 socket, 5-pos., B-coded, female side
Cable cross section
PROFIBUS[910]
Dimensioned drawing
47,3
Ø12
M12
Ø14,8
Plug, M12 x 1, straight, shielded
Dimensioned drawing
44,5
M12
Ø15
Ø12
M12 x 1 socket, straight, shielded
Circuit diagram
1 1
2 2
4 4
3 3
5 5
Contact assignment of the M12 connector and the M12 socket
Phoenix Contact 2014 © - all rights reserved