Figure 2. PX3 Series External Freeze/Thaw Resistance
Reduced current consumption: Helps to reduce energy
costs, and enhances product life if used in battery driven
systems.
Media compatibility: Common HFC (hydrouorocarbon)
refrigerants such as R410A and R134A, next generation low
global warming potential (GWP) refrigerants such as R448A
(Solstice® N40), R32 and R1234ZE, engine oil, petroleum-
based hydraulic fluids, DOT 3 brake fluid, and dry air. For
ammonia and other corrosive media, see Honeywell’s SPT Series.
DIFFERENTIATION
Optional diagnostics mode: Beneficial in applications where
the sensor functionality and the need to know internal or
external failure modes is critical.
Great customer value: Multiple configuration possibilities
provide flexibility of use in the application with no upfront
NRE or tooling charges.
Durable: Provides the tough environmental specifications
needed, including insulation resistance and dielectric
strength, external freeze-thaw resistance (see Figure 2),
and EMC performance.
FEATURES
Pressure range: 1 bar to 50 bar | 15 psi to 700 psi (absolute
and sealed gage)
Ratiometric output: 0.5 Vdc to 4.5 Vdc or 0.33 Vdc to 2.97 Vdc
Fully calibrated and temperature compensated
Total Error Band: ±1.0 %FSS from -20°C to 85°C [-4°F to 185°F]
External freeze/thaw resistance: 6 cycles from -30°C to
50°C [-22°F to 122°F]
Insulation resistance: >100 MOhm, 1500 Vdc (in dry, non-
ionized air)
Dielectric strength: AC1500V, 1 min. or AC1800V, 1 s (in dry, non-
ionized air)
Current consumption: 3.5 mA max.
EMC (radiated immunity): 200 V/m per ISO 11452-2
Ingress protection IP67 (Metri-Pack 150), IP69K (cable harness)
Response time: <2 ms
RoHS, REACH, and CE compliant
Six industry-standard pressure port types, including a
tube port which provides for hermetically-sealed process
connection
POTENTIAL APPLICATIONS
Industrial: Refrigerant pressure monitoring in HVAC/R
systems; air compressor system pressure
Transportation: Air system monitoring; hydraulic oil pressure
monitoring
The PX3 Series is not recommended for use with media
involving water, saturated air such as steam and vapor, and
ammonia.
PORTFOLIO
Honeywell’s PX3 Series joins the PX2 Series, MLH Series, and
SPT Series heavy duty pressure transducers.
Sensing and Internet of Things
DESCRIPTION
Honeywell’s PX3 Series Heavy Duty Pressure Transducers
use piezoresistive sensing technology with ASIC (Application
Specific Integrated Circuit) signal conditioning in a brass
housing and Metri-Pack 150 or cable harness electrical
connections. The PX3 Series are fully calibrated and
temperature compensated from -40°C to 125°C [-40°F to
257°F].
VALUE TO CUSTOMERS
Total Error Band (TEB) ±1.0 %FSS from -20°C to
85°C: Provides the most comprehensive, clear and
meaningful indication of the sensors true measurement
performance over a specified temperature range; small
error promotes system uptime and efficiency. (See Figure 1.)
Figure 1. TEB Definition and Temperature Performance
High insulation resistance and dielectric strength: Protect
the user and sensor in high over-voltage situations,
and ensures that the device is compliant with industry
standards.
High EMC performance: Operates reliably in the presence
of electro-magnetic fields, such as near wireless signals, RF
communication, and electrical devices.
High external freeze/thaw resistance: Survives exposure to
frost, commonly found in refrigeration systems. (See Figure 2.)
Total
Error
Band
Accuracy
BFSL
All Possible Errors
Thermal Hysteresis
Thermal Effect on Offset
Thermal Effect on Span
Pressure Non-Linearity
Pressure Hysteresis
Full Scale Span
Offset
Pressure Non-Repeatability
-20°C
[-4°F]
-40°C
[-40°F]
0
85°C
[185°F]
0°C
[32°F]
125°C
[257°F]
1
2
3
-1
-2
-3
Temperature (°C [°F])
Total Error Band (%FSS)
Total Error Band
(Shown with mating connector. See Figure 5.)
Datasheet
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
32313757
Issue D
2Sensing and Internet of Things
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
Table 1. Electrical Specifications
Characteristic Parameter
Supply voltage:
5 Vdc
3.3 Vdc
±0.25 Vdc
±0.25 Vdc
Over voltage and reverse voltage ±16 Vdc
Current consumption:
5 Vdc supply
3.3 Vdc supply
3.0 mA max.
1.6 mA to 2.1 mA
Short circuit protection yes
Nominal output transfer function:
5 Vdc supply
3.3 Vdc supply
0.5 Vdc to 4.5 Vdc (ratiometric to supply)
0.33 Vdc to 2.97 Vdc (ratiometric to supply)
Table 2. Performance Specifications (At 25°C [7F] and under unless otherwise noted.)
Characteristic Parameter
Operating temperature range1-40°C to 12C [-40°F to 257°F]
Storage temperature range1-40°C to 125°C [-40°F to 257°F]
Compensated temperature range -40°C to 125°C [-40°F to 25F]
Total Error Band2:
-20°C to 85°C [-F to 18F]
<-20°C, >8C [<-F, >185°F]
±1.0 %FSS
±2.0 %FSS
Accuracy BFSL3±0.25 %FSS
Response time <2 ms (10% to 90% step change in pressure)
Turn on time4<7 ms
EMC rating5:
surge immunity (all leads)
electrostatic discharge
radiated immunity
fast transient burst
immunity to conducted disturbances
radiated emissions
radiated immunity
±1000 V line to ground per IEC 61000-4-5
±4 kV contact, ±8 kV air per IEC 61000-4-2
10 V/m (80 MHz to 1000 MHz) per IEC 61000-4-3
±1 kV per IEC 61000-4-4
3 V per IEC 61000-4-6
40 dB (30 MHz to 230 MHz), 47 dB (230 MHz to 1000 MHz) per CISPR 11
200 V/m per ISO 11452-2
Insulation resistance >100 MOhm, 1500 Vdc (in dry, non-ionized air)
Dielectric strength AC1500V, 1 min. or AC1800V, 1 s (in dry, non-ionized air)
Load resistance >5 kOhm
Life greater than 10 million full scale pressure cycles over the calibrated pressure range
1 Dependent on external and internal seal and cable jacket materials. See Table 5 and Figure 5 for temperature range details.
2 Total Error Band: The maximum deviation from the ideal transfer function over the entire compensated temperature and pressure range. Includes all
errors due to offset, full scale span, pressure non-linearity, pressure hysteresis, pressure non-repeatability, thermal effect on offset, thermal effect
on span, and thermal hysteresis. See Figure 1.
3 Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 2C
[77°F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and pressure non-repeatability. See Figure 1.
4 Turn on Time: Duration from power applied until first valid output.
5 Tested using 1.5 m [59.1 in] cable.
Table 3. Pressure Reference Definitions
Pressure Reference Definition
Absolute Output is calibrated to be proportional to the difference between applied pressure and a fixed reference to
perfect vacuum (absolute zero pressure).
Sealed gage1
Sensor construction is identical to the absolute version with a built in reference at zero pressure in order to
minimize measurement error over temperature. The output is calibrated to be proportional to the difference
between applied pressure and a reference of 1 standard atmosphere (1.013 barA | 14.7 psiA). Example: 100
psi sealed gage has a calibrated pressure range from 14.7 psi absolute to 114.7 psi absolute. (See Figure 3.)
1 Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.
3
Sensing and Internet of Things
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
Table 4. Pressure Ratings
bar psi
Operating
Pressure
Over-
pressure
Burst
Pressure
Operating
Pressure
Over-
pressure
Burst
Pressure
1 5 8 15 70 115
1.6 5 8 30 150 250
210 17 50 250 400
2.5 10 17 100 450 750
417 27 150 450 750
631 51 200 450 1150
831 51 250 450 1150
10 31 51 300 1000 1500
16 32 80 500 1000 1500
20 69 103 600 1000 1500
25 69 103 667 1000 1500
35 69 103 700 1000 1500
40 69 103 - - -
46 69 103 - - -
50 69 103 - - -
Figure 3. Ratiometric Output Option AA for 100 psi,
Absolute vs Sealed Gage
0
1.5
2
2.5
3
1
0.5
0
Pressure (psi Absolute)
Output (V)
20 40 60 80 100 120 140
3.5
4
4.5
5
14.7 114.7
100 psi absolute
100 psi sealed gage
Table 5. Output Transfer Function Codes
Fault Condition Analog Diagnostic Rail
EEPROM Corrupt below lower rail
Sensor Bridge Open
(any element) above upper rail
Sensor Bridge Short
(any element) above upper rail
Low supply voltage below lower rail
Loss of ground connection above upper rail
Diagnostics Mode
The PX3 Series diagnostics mode allows the device to
indicate when internal or external faults occur. If an internal
fault occurs, the output will rail to the preset lower or upper
limit values shown in Figure 4 and Table 5.
External faults will result in the sensor’s output exceeding
those preset limits (lower or upper). (For example, if the
external sensor ground (signal) were lost, the sensor output
would exceed the upper rail of 97.5%.)
Figure 4. Analog Output with Diagnostics
Pressure (psi)
10
020 30 40 50 60 70 80 90 100
Output (%Vsupply)
10
20
30
40
50
60
70
80
90
100
Upper Rail (97.5%)
Lower Rail (2.5%)
4Sensing and Internet of Things
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
Table 6. Environmental and Mechanical Specifications
Characteristic Parameter
Shock:
threaded ports
tube port
100 G per MIL-STD-202G, Method 213B, Cond. F (at 25°C [77°F])
100 G per MIL-STD-202F, Method 213B, and Condition C
Vibration:
threaded ports
tube port
20 G sweep, 10 Hz to 2000 Hz (at 25°C [77°F])
10 Hz to 55 Hz, 2 mm displacement, tested as per IEC 60068-2-6; Test FC. (at 25°C [7F])
Ingress protection:
Metri-Pack 150 electrical connector
cable harness electrical connector
IP67
IP69K
Ambient humidity 0 %RH to 95 %RH, non-condensing
External freeze/thaw resistance >6 cycles from -30°C to 50°C [-2F to 122°F]
Wetted materials:
threaded ports
tube port
braze filler
internal O-ring media seal
sensing element and substrate
adhesives
brass C36000; lead (Pb) content: 3.7% max.
copper UNS C12200; lead (Pb) free
silver and copper alloy
seal material as required by the application (see seal material media compatibility options below)
alumina, glass, silicon
epoxy
Internal O-ring material media compatibility1:
HNBR (option H)
silicone (option S)
refrigerants, engine oil, petroleum-based hydraulic fluid
dry air
Other materials:
Metri-Pack 150 electrical connector
external O-ring seal on G1, M1 ports
PBT 30% GF
nitrile (-30°C to 125°C [-22°F to 257°F])
1 Honeywell can assist with selecting suitable O-ring seal material for the media based on the seal manufacturer’s recommendation.
The customer should test the compatibility with the media to ensure that it is correct for the application.
CAUTION
PRODUCT DAMAGE DUE TO MECHANICAL ISSUES
Ensure torque specifications are determined for the specific application. Values provided are for reference only. (Mating
materials and thread sealants can result in significantly different torque values from one application to the next.)
When using mating parts made of stainless steel, use a thread sealant with anti-seize properties to prevent thread galling.
Ensure the sealant is rated for the application.
Use appropriate tools (such as an open ended wrench or deep well socket) to install transducers.
Always hand-start transducers into the hole to prevent cross threading and damage.
Ensure that torque is not applied to the electrical connector.
Ensure that the proper mating electrical connector with a seal is used to connect the transducer. Improper or damaged
seals can compromise ingress protection, leading to short circuits.
Failure to comply with these instructions may result in product damage.
CAUTION
PRODUCT DAMAGE TO TUBE PRESSURE PORT TYPE DURING BRAZING
Ensure that the temperature of the brass port and plastic connector is maintained below 125°C during flame brazing.
Exposure to temperatures higher than 12C can cause permanent product damage and can compromise ingress protection
leading to short circuits.
Failure to comply with these instructions may result in product damage.
CAUTION
PRODUCT DAMAGE DUE TO PARTICULATES
Ensure that a filter is used upstream of the transducer to keep media flow free of larger particulates and increased humidity. All
PX3 Series transducers are dead-ended devices; particulate accumulation and condensing moisture may affect sensor output.
It is recommend that the transducer be positioned with the port facing downwards; any particulates in the system are less
likely to enter and settle within the pressure transducer if it is in this position.
Ensure that the media does not create a residue when dried. Build-up inside the transducer may affect transducer output;
rinsing of a dead-ended transducer is potentially difficult and has limited effectiveness in removing residue.
Failure to comply with these instructions may result in product damage.
5
Sensing and Internet of Things
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
Figure 5. Nomenclature and Order Guide
PX3 A N1 B S 150P A AA X
Electrical Connector Type
2
H
HNBR (Hydrogenated Nitrile Butadiene Rubber):
-30°C to 125°C [-22°F to 257°F] (50 hr at 135°C [257°F)
S Silicone: -40
°
C to 125
°
C [-40°F to 257°F]
Special
Housing Body Materia
l
Output Transfer Function
Internal O-ring Material and Temperature Range
2,8
Heavy Duty
Pressure Transducer1
For example, PX3AN1BS150PAAAX defines a PX3 Series Heavy Duty Pressure Transducer, Metri-Pack 150,
standard (UL V-0) electrical connector type, 1/4-18 NPT pressure port type, brass housing body, silicone:
-40°C to 125°C [-40°F to 257°F] seal material and temperature range, 150 psi pressure range, absolute pressure
reference, ratiometric: 0.5 Vdc to 4.5 Vdc output transfer function, no special
PX3
A
F1
7/16-20 UNF
1/4 inch 45° Flare
Female Schrader
(SAE J512)
N1
N2
1/4-18 NPT
1/8-27 NPT
M12 x 1.5
(ISO 6149-3)
G1/4 A-G
(ISO 1179-3)
M1
G1
1
Not all catalog listing combinations are shown. Custom products are
available. Please contact Honeywell.
2
Custom configurations such as varied cable lengths, end mating connectors,
different O-ring materials, and different pressure ranges are available.
3
Metri-Pack 150 mating connectors with shielded cable and three 22 AWG
wires are available from Honeywell. Order part no. 3685301 for 1 m [3.2 ft] cable
length and part no. 3685302 for 3 m [9.8 ft] cable length.
4
PVC Flame Retardant (FR) type cable is FT1 rated per IEC60332-1; XLPE
non-flame retardant cable is FT2 rated per IEC60332-1.
5
See Table 6 for pressure port materials.
6
See page 3 for Diagnostics Mode information.
7
Sealed gage option only available in pressure ranges at or above 8 bar | 100 psi.
8
See Table 6 f
or O-ring s
eal material media compatibility.
Metri-Pack 150,
Standard (UL V-0)3
Pressure Reference
Pressure Range
3
Pressure Port Type
5
psi
bar
015P
030P
050P
100P
150P
200P
250P
300P
500P
600P
667P
700P
001B
1.6B
002B
2.5B
004B
006B
008B
010B
016B
020B
025B
035B
040B
046B
050B
1 bar
1.6 bar
2 bar
2.5 bar
4 bar
6 bar
8 bar
10 bar
16 bar
20 bar
25 bar
35 bar
40 bar
46 bar
50 bar
15 psi
30 ps
i
50 psi
100 psi
150 psi
200 psi
250 psi
300 psi
500 psi
600 psi
667 psi
700 psi
X
Series
B Brass (C36000)
A Absolute
S Sealed gage7
Mating Connector
3
AA Ratiometric, 5.0 V: 10% to 90% Vs
DA
Ratiometric, 5.0 V: 10% to 90% Vs (diagnostics on)
6
AC Ratiometric, 3.3 V: 10% to 90% Vs
DC
Ratiometric, 3.3 V: 10% to 90% Vs (diagnostics on)6
T1 Tube
PVC Cable with three
22 AWG wires: 1 m [3.2 ft]4
-40°C to 100°C
[-40°F to 212°F]
PVC Cable with three
22 AWG wires: 2 m [6.6 ft]4
-40°C to 100°C
[-40°F to 212°F]
XLPE Cable with three
22 AWG wires: 1 m [3.2 ft]4
-40°C to 125°C
[-40°F to 257°F]
XLPE Cable with three
22 AWG wires: 2 m [6.6 ft]4
-40°C to 125°C
[-40°F to 257°F]
E
F
M
N
6Sensing and Internet of Things
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
Figure 6. Metri-Pack Mounting Dimensions (For reference only. mm/[in].) E
Pinout General
product
marking
F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512)
Seal: 45° cone
Mating geometry: SAE J512
Installation torque: 17 N m [12.5 ft-lb]
Weight: 54,5 g [1.9 oz]
G1: G1/4 A-G (ISO 1179-3)
Seal: nitrile O-ring (included)
Mating geometry: ISO 1179-1
Installation torque: 50 N m [36.9 ft-lb]
Weight: 35,1 g [1.2 oz]
M1: M12 x 1.5 (ISO 6149-3)
Seal: Nitrile O-ring (included)
Mating geometry: ISO 6149-1
Installation torque: 25 N m [18.4 ft-lb]
Weight: 33,9 g [1.2 oz]
N1: 1/4-18 NPT
Seal: Pipe thread
Mating geometry: ANSI B1.20.1
Installation torque: Two to three turns from finger tight
Weight: 35,1 g [1.2 oz]
N2: 1/8-27 NPT
Seal: Pipe thread
Mating geometry: ANSI B1.20.1
Installation torque: Two to three turns from finger tight
Weight: 31,2 g [1.1 oz]
T1: Tube
Seal: Brazing
Weight: 32 g [1.1 oz]
ø17,0
[0.67]
ø21,60
[0.85]
ø15,9
[0.63]
12,2
[0.48]
15,4
[0.61]
37,4
[1.47]
49,6
[1.95]
7/16-20 UNF 1/4 in 45° Flare
Female Schrader (SAE J512)
35,9
[1.41]
13,9
[0.55]
11,2
[0.44]
1,85
[47.1]
ø17,0
[0.67]
ø21,60
[0.85]
G1/4 A-G (ISO 1179-3)
M12 x 1.5 (ISO 6149-3)
34,9
[1.37]
13,9
[0.53]
12,9
[0.51]
48,4
[1.91]
ø
17,0
[0.67]
ø21,60
[0.85]
50
[2.0]
15,0
[0.59]
35
[1.4]
13
[0.5]
ø17,0
[0.67]
ø21,60
[0.85]
1/4-18 NPT
36
[1.4]
46
[1.8] 14
[0.5]
10,0
[0.39]
ø
17,0
[0.67]
ø21,60
[0.85]
1/8-27 NPT
22,0
[0.87]
Pin A
Pin B
Pin C
Pin A = Ground
Pin B = Vsupply
Pin C = Vout
Pin B
Pin C
T1
F1, G1, N1, N2, M1
Pin A
ø17,0
[0.67]
ø23,0
[0.91]
ø7,3
[0.29]
ø6,35
[0.25]
39,5
[1.56]
96,5
[3.80]
57,0
[2.24]
7,0
[0.27]
Ensure this area is
protected during the
brazing process so
that temperatures
do not exceed
125°C [257°F].
Yellow lettering
7
Sensing and Internet of Things
Heavy Duty Pressure Transducers
PX3 Series, 1 bar to 50 bar | 15 psi to 700 psi
Figure 7. Cable Harness Mounting Dimensions Shown by Pressure Port Type (For reference only. mm/[in].) E
Wire
colors
General
product
marking
F1: 7/16-20 UNF 1/4 inch 45° Flare Female Schrader (SAE J512)
Seal: 45° cone
Mating geometry: SAE J512
Installation torque:
17 N m [12.5 ft-lb]
Weight: 90 g [3.2 oz]
G1: G1/4 A-G (ISO 1179-3)
Seal: nitrile O-ring (included)
Mating geometry: ISO 1179-1
Installation torque:
50 N m [36.9 ft-lb]
Weight: 70 g [2.5 oz]
M1: M12 x 1.5 (ISO 6149-3)
Seal: nitrile O-ring (included)
Mating geometry:
ISO 6149-1
Installation torque:
25 N m [18.4 ft-lb]
Weight: 69 g [2.4 oz]]
N1: 1/4-18 NPT
Seal: Pipe thread
Mating geometry:
ANSI B1.20.1
Installation torque:
Two to three turns
from finger tight
Weight: 70 g [2.5 oz]
N2: 1/8-27 NPT
Seal: Pipe thread
Mating geometry:
ANSI B1.20.1
Installation torque:
Two to three turns
from finger tight
Weight: 66 g [2.3 oz]
T1: Tube
Seal: Brazing
Weight: 67 g [2.4 oz]
ø21,6
[0.85]
1000 ±50
[39.9 ±1.9]
13,9
[0.55]
11,2
[0.44]
31,6
[1.24]
42,75
[1.683]
G1/4 A-G (ISO 1179-3)
44,1
[1.73]
13,5
[0.53]
ø21,6
[0.85]
30,6
[1.20]
12,9
[0.51]
1000 ±50
[39.9 ±1.9]
M12 x 1.5 (ISO 6149-3)
ø21,6
[0.85]
1000 ±50
[39.9 ±1.9]
30,6
[1.20]
45,6
[1.79] 12,9
[0.51]
15,0
[0.59] 1/4-18 NPT
ø21,6
[0.85]
1000 ±50
[39.9 ±1.9]
31,6
[1.24]
13,9
[0.55]
10,0
[0.39]
41,6
[1.64]
1/8-27 NPT
ø23,0
[0.91]
ø7,3
[0.29]
ø6,35
[0.25]
7,0
[0.27]
57,0
[2.24]
1000 ±50
[39.9 ±1.9]
92,2
[3.63]
32,2
[1.38]
Ensure this area is
protected during the
brazing process so that
temperatures do not
exceed 125°C [257°F].
22,0
[0.87]
Black = Ground
Red = Vsupply
White = Vout
T1
F1, G1, N1, N2, M1
White label with
black lettering
Find out more
Honeywell serves its customers through
a worldwide network of sales offices and
distributors. For application assistance,
current specifications, pricing or name
of the nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
sensing and switching products, call
+1.815.235.6847 or 1.800.537.6945,
visit sensing.honeywell.com, or e-mail
inquiries to info.sc@honeywell.com
Honeywell Safety and Internet of Things
9680 Old Bailes Road
Fort Mill, SC 29707
www.honeywell.com
Warranty/Remedy
Honeywell warrants goods of its manufacture as being free
of defective materials and faulty workmanship during the
applicable warranty period. Honeywell’s standard product
warranty applies unless agreed to otherwise by Honeywell
in writing; please refer to your order acknowledgement or
consult your local sales office for specific warranty details.
If warranted goods are returned to Honeywell during the
period of coverage, Honeywell will repair or replace, at its
option, without charge those items that Honeywell, in its sole
discretion, finds defective. The foregoing is buyer’s sole
remedy and is in lieu of all other warranties, expressed or
implied, including those of merchantability and fitness for
a particular purpose. In no event shall Honeywell be liable
for consequential, special, or indirect damages.
While Honeywell may provide application assistance
personally, through our literature and the Honeywell web site, it
is buyers sole responsibility to determine the suitability of the
product in the application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this writing.
However, Honeywell assumes no responsibility for its use.
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
The information presented in this datasheet is for
reference only. Do not use this document as a product
installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
ADDITIONAL INFORMATION
The following associated literature is available on the
Honeywell web site at sensing.honeywell.com:
Product line guide
Product range guide
Product installation instructions
Application notes:
- Heavy Duty Pressure Transducers, PX2 Series and PX3
Series
- PX2 Series and PX3 Series Heavy Duty Pressure
Transducers for Potential Use in Industrial Refrigeration
- PX2 Series and PX3 Series Heavy Duty Pressure
Transducers for Potential Use in Industrial HVAC/R
Applications
Technical notes:
- Total Error Band Specification for Honeywell Heavy
Duty Pressure Transducers, PX2 Series and PX3 Series
- Media Compatibility for Honeywell Heavy Duty
Pressure Transducers, PX2 Series and PX3 Series
CAD models
32313757-D-EN | D | 06/17
© 2017 Honeywell International Inc.
Solstice® N40 is a registered trademark of Honeywell International Inc.