CHIP
RESISTORS
CTA
Vishay Electro-Films
Thin Film, Center-Tapped Resistor
www.vishay.com For technical questions, contact: efi@vishay.com Document Number: 61015
68 Revision: 12-Mar-08
The CTA series resistor chips combine the best tolerances,
stability and low shunt capacitance. The CTA offers the
designer flexibility in use as either a single value resistor or
as two resistors with a center tap feature. The CTAs six
bonding pads allows the user increased layout flexibility. The
CTAs are manufactured using Vishay Electro-Films (EFI)
sophisticated thin film equipment and manufacturing
technology. The CTAs are 100 % electrically tested and
visually inspected to MIL-STD-883.
APPLICATIONS
The CTA center-tapped resistor chips are used mainly in
feedback circuits of amplifiers where ratio matching, low
shunt capacitance and tracking between two resistors is
critical.
Recommended for hermetic environments where chip is not
exposed to moisture.
For lower values, the resistance of the six bonding-pad
configurations can vary, depending on the method of
measurement used. Vishay EFI measures low-value
resistors by the four-wire Kelvin technique. The measuring
method is illustrated in the diagram to the right.
FEATURES
Wire bondable
Center tap feature
Tight ratio tolerances to: ± 0.1 %
Chip size: 0.030 inches square
Resistance range total: 25 Ω to 35 kΩ
Alumina substrate, low shunt capacitance: < 0.2 pF
Resistor material nichrome
Excellent stability: ± 0.025 % maximum ΔR/R
*10ppm/°C for R < 100
Product may not
be to scale
III
R
A
R
B
VVV
TEMPERATURE COEFFICIENT OF RESISTANCE, VALUES AND TOLERANCES
PROCESS CODE
CLASS H* CLASS K*
203 233
202 232
200 230
201 231
*MIL-PRF-38534 inspection criteria
± 100 ppm/°C
± 25 ppm/°C
± 50 ppm/°C
0.1 %
35 kΩ200 Ω100 Ω25 Ω20 kΩ
Tightest Standard Tolerance Available
± 10 ppm/°C
1 kΩ
STANDARD ELECTRICAL SPECIFICATIONS
PARAMETER
TCR Tracking Between Halves (RA/RB) ± 2 ppm/°C*
Center Tap Ratio, RA/RB: Tolerance 1 ± 1 % standard
Noise, MIL-STD-202, Method 308 - 35 dB typ.
Moisture Resistance, MIL-STD-202, Method 106, (Passivated only) ± 0.5 % max. ΔR/R
Stability, 1000 h, + 125 °C, 62 mW ± 0.025 % max. ΔR/R
Operating Temperature Range- 55 °C to + 125 °C
Thermal Shock, MIL-STD-202, Method 107, Test Condition F ± 0.1 % max. ΔR/R
High Temperature Exposure, + 150 °C, 100 h ± 0.1 % max. ΔR/R
Insulation Resistance 1012 min.
Operating Voltage100 V max.
DC Power Rating at + 70 °C (Derated to Zero at + 150 °C) 125 mW
5 x Rated Power Short-Time Overload, + 25 °C, 5 s ± 0.25 % max. ΔR/R %
www.vishay.com For technical questions, contact: efi@vishay.com Document Number: 61015
69 Revision: 12-Mar-08
CHIP
RESISTORS
CTA
Thin Film, Center-Tapped Resistor Vishay Electro-Films
DIMENSIONS in inches
SCHEMATIC
Options: Aluminum bonding pads, 10 kÅ minimum
Center-tap ratio tolerances to 0.02 % R > 1 kΩ
Consult Applications Engineer
0.030
0.005
0.030
STANDARD CONFIGURATION
*Six locations. All pads 0.005 x 0.005
R
A
R
B
R
T =
R
A +
R
B
MECHANICAL SPECIFICATIONS in inches
PARAMETER
Chip Size 0.030 x 0.030 ± 0.002 (0.762 x 0.762 ± 0.050 mm)
Chip Thickness 0.010 ± 0.002 (0.254 ± 0.05 mm)
Chip Substrate Material 99.6 % alumina
Resistor Material Nichrome
Bonding Pad Size 0.005 x 0.005 (0.127 x 0.127 mm)
Number of Pads 6
Pad Material 25 kÅ minimum gold
Backing None
ORDERING INFORMATION
Example: 100% visual, 10 kΩ, ± 1 %, ± 100 ppm/°C TCR, gold pads, class H visual inspection
W
INSPECTION/
PACK AGING
W = 100 % visually inspected
parts in matrix trays per
MIL-STD-883
X = Sample, visually inspected
parts loaded in matrix
trays (4 % AQL)
CTA
PRODUCT
FAMILY
201
PROCESS
CODE
See Process Code
table
1000
RESISTANCE
VALUE
Use first 4 digits
significant digits of the
resistance (RT)
1
MULTIPLIER
CODE
B = 0.01
A = 0.1
0 = 1
1 = 10
F
TOLERANCE
CODE
A = 0.05 %
B = 0.1 %
C = 0.2 %
D = 0.5 %
F = 1.0 %
G = 2.0 %
H = 2.5 %
J = 5.0 %
K = 10 %
Document Number: 91000 www.vishay.com
Revision: 18-Jul-08 1
Disclaimer
Legal Disclaimer Notice
Vishay
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.