138 PCB Relay G5NB
Specifications
■Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
■Contact Ratings
■Characteristics
Note: 1. The data shown above are initial value.
2. Measurement conditions: 5 VDC, 1 A, voltage drop method
3. Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter.
4. This value is for a switching frequency of 120 operations/minute. (P level: λ60 = 0.1 x 10-6 operations)
Rated voltage 5 VDC 12 VDC 18 VDC 24 VDC
Rated current 40.0 mA 16.7 mA 11.1 mA 8.3 mA
Coil resistance 125 Ω720 Ω1,620 Ω2,880 Ω
Must operate voltage 75% of rated voltage (max.)
Must release voltage 10% of rated voltage (min.)
Max. voltage Standard: 180% of rated voltage (at 23°C)
High-capacity: 170% of rated voltage (at 23°C)
Power consumption Approx. 200 mW
Load Standard High-capacity
Rated load (resistive, p.f.= 1) 3 A at 125 VAC
3 A at 30 VDC
5 A at 250 VAC
3 A at 30 VDC
Max. switching voltage 250 VAC, 30 VDC 250 VAC, 30 VDC
Rated carry current
Max. switching current
3 A
3 A
5A
5A (AC load,) 3A (DC load)
Max. switching power 375 VA, 90 W 1,250 VA, 90 W
Contact resistance (see note 2) 100 mΩ max.
Operate time 10 ms max.
Release time 10 ms max.
Insulation resistance (see note 3) 1,000 MΩ min. (at 500 VDC)
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min. between coil and contacts
750 VAC, 50/60 Hz for 1 min. between contacts of same polarity
Impulse withstand voltage 10,000 V (1.2 x 50 μs) between coil and contacts
Vibration resistance Destruction:
Malfunction:
10 to 55 Hz, 1.5-mm double amplitude
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction:
Malfunction:
1,000 m/s2 (approx. 100 G)
100 m/s2 (approx. 10 G)
Life expectancy Mechanical: 5,000,000 operations min. (18,000 operations/hour)
Electrical: 200,000 operations minimum:
High-capacity
5 A at 125 VAC
3 A at 30 VDC
Standard
3 A at 125 VAC
3 A at 30 VDC
100,000 operations minimum:
High-capacity
5 A at 250 VAC
All electrical load ratings are resistive, with operation frequency = 1,800 operations/hour.
Minimum permissible load
(reference value) (see note 4)
5 VDC, 10 mA
Ambient temperature Operating: –40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 4 g