PCB Relay G5NB 137
PCB Relay
G5NB
A Slim Compact Relay with 3 A Switching
Capability and 10-kV Impulse Withstand
Voltage
Max size 20.5L x 7.2 W x 15.3 W mm.
Standard models switch up to 3 A
High-capacity models switch up to 5 A (AC loads only).
Low power consumption (200 mW).
Semi-sealed and sealed types available.
UL recognized / CSA certified. VDE Approved.
RoHS Compliant.
RC
Ordering Information
Model Number Legend
1. Number of Poles
1: 1 pole
2. Contact Form
A: SPST-NO
3. Enclosure Ratings
None: Flux protection
4: Sealed
4. Type
None: Standard
E: High Capacity
5. Rated Coil Voltage
5, 12, 18, 24 VDC
Application Examples
Water heaters, refrigerators, air conditioners, and small electric appliances
Contact Form SPST-NO
Classification Enclosure ratings
Flux-tight model Sealed model
Standard G5NB-1A G5NB-1A4
High Capacity G5NB-1A-E G5NB-1A4-E
245
45
138 PCB Relay G5NB
Specifications
Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Contact Ratings
Characteristics
Note: 1. The data shown above are initial value.
2. Measurement conditions: 5 VDC, 1 A, voltage drop method
3. Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter.
4. This value is for a switching frequency of 120 operations/minute. (P level: λ60 = 0.1 x 10-6 operations)
Rated voltage 5 VDC 12 VDC 18 VDC 24 VDC
Rated current 40.0 mA 16.7 mA 11.1 mA 8.3 mA
Coil resistance 125 Ω720 Ω1,620 Ω2,880 Ω
Must operate voltage 75% of rated voltage (max.)
Must release voltage 10% of rated voltage (min.)
Max. voltage Standard: 180% of rated voltage (at 23°C)
High-capacity: 170% of rated voltage (at 23°C)
Power consumption Approx. 200 mW
Load Standard High-capacity
Rated load (resistive, p.f.= 1) 3 A at 125 VAC
3 A at 30 VDC
5 A at 250 VAC
3 A at 30 VDC
Max. switching voltage 250 VAC, 30 VDC 250 VAC, 30 VDC
Rated carry current
Max. switching current
3 A
3 A
5A
5A (AC load,) 3A (DC load)
Max. switching power 375 VA, 90 W 1,250 VA, 90 W
Contact resistance (see note 2) 100 mΩ max.
Operate time 10 ms max.
Release time 10 ms max.
Insulation resistance (see note 3) 1,000 MΩ min. (at 500 VDC)
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min. between coil and contacts
750 VAC, 50/60 Hz for 1 min. between contacts of same polarity
Impulse withstand voltage 10,000 V (1.2 x 50 μs) between coil and contacts
Vibration resistance Destruction:
Malfunction:
10 to 55 Hz, 1.5-mm double amplitude
10 to 55 Hz, 1.5-mm double amplitude
Shock resistance Destruction:
Malfunction:
1,000 m/s2 (approx. 100 G)
100 m/s2 (approx. 10 G)
Life expectancy Mechanical: 5,000,000 operations min. (18,000 operations/hour)
Electrical: 200,000 operations minimum:
High-capacity
5 A at 125 VAC
3 A at 30 VDC
Standard
3 A at 125 VAC
3 A at 30 VDC
100,000 operations minimum:
High-capacity
5 A at 250 VAC
All electrical load ratings are resistive, with operation frequency = 1,800 operations/hour.
Minimum permissible load
(reference value) (see note 4)
5 VDC, 10 mA
Ambient temperature Operating: –40°C to 70°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 4 g
PCB Relay G5NB 139
Approved Standards
UL Recognized (File No. E41515)
CSA Certified (File No. LR31928)
Actual Load Life (Reference Values)
1. 120-VAC motor and lamp load (2.5-A surge and 0.5-A normal): 250,000 operations min. (at 23°C)
2. 160-VDC valve load (with varistor) (0.24-A): 250,000 operations min. (at 23°C)
Engineering Data
Coil ratings Contact ratings
5 to 24 VDC 3 A at 30 VDC (Resistive), 70°C
3 A at 125 VAC (Resistive), 70°C
Coil ratings Contact ratings
5 to 24 VDC 3 A at 30 VDC (Resistive)
3 A at 125 VAC (Resistive)
Switching voltage (V)
10
3
1
0.1
1 10 30 100 250 1,000
DC resistive
load
AC resistive
load
Contact
resistance
Maximum Switching Capacity
Contact current (A)
100
50
30
10
5
3
1
0 1 2 3 4
125 VAC, 30 VDC resistive load
Electrical Service Life
Switching current (A)
Service Life ( 104 operations)
Standard models
Electrical Service Life
High-capacity models
140 PCB Relay G5NB
Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Precautions
Correct Use
Handling
Note: 1. The enclosure rating for G5NB-1A and G5NB-1A-E is suitable for flux protection. Do not use immersion-cleaning for these model
2. Do not ultrasonic clean any G5NB relay.
Ambient Temperature vs. Maximum Coil Voltage
Maximum coil voltage (%)
Ambient temperature (°C)
Test item: G5NB-1A, 24 VDC
Quantity tested: 5
No current
3-A current
Uncon-
firmed
area
40 60 70 80100
120
140
160
200
220
80
100
180
020 23
Z
Z
Z'
Z'
Shock direction
Unit: m/s2
Y
Y
Y'
Y'
X
X
X'
X'
1,000
1,000
1,000 1,000
1,000 1,000
Excited
Not excited
700
125
Malfunctioning Shock
G5NB-1A
Quantity Tested: 5 units
Test Method: Shock was applied 3
times in 6 directions along 3 axes
and the level at which shock caused
malfunction was measured.
Rating: 100 m/s2
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
Terminal Arrangement/
Internal Connections
(Bottom View)
7.2 max.
(7.0)*
Four, 1.1 dia.
(No coil polarity)
*Average value
15. 3 max.
(15.0)*
3.4
0.4
11.5 7
0.27 0.33
20.5 max.
(20.4)*
G5NB-1A(4)(-E)
PCB Relay G5NB
MEMO
PCB Relay G5NB
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. X301-E-1b Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11 Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.