SPECIFICATION
MODEL RT-125A RT-125B RT-125C RT-125D
DCVOLTAGE
RATEDCURRENT
OUTPUT VOLTAGE ADJ.RANGE
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V
CH2 CH2 CH2 CH2
-5V
CH3 CH3 CH3 CH3
12V -12V 5V 5V15V 24V-15V 12V5V
12A 5.5A 1A 5A 1A 10A 8A4.5A 3A1A 2A12A
2~15A 0.5~6A 0.1~1A 0.5~6A 0.1~1A 2~15A 2~15A0.5~6A
0.4~4A
0.1~1A 0.1~2A2~15A
131W 132W 132.5W 136W
80mVp-p
120mVp-p
80mVp-p
120mVp-p
120mVp-p
80mVp-p 80mVp-p
150mVp-p
150mVp-p
150mVp-p
120mVp-p
80mVp-p
CH1:4.75~5.5V CH1:4.75~5.5V CH1:4.75~5.5V CH1:4.75~5.5V
2.0% +8,-3% +6,-10% +8,-3% 6.0% 2.0% 2.0%+8,-3% 6.0% 6.0%
6.0%
2.0%
0.5% 1.0% 1.0% 1.0% 0.5% 0.5%1.0% 1.0%
5.0%
1.0% 1.0%0.5%
1.0% 3.0% 6.0% 3.0% 6.0%
1.0%
1.0% 1.0%3.0% 3.0%6.0%1.0%
500ms,20ms/230VAC1200ms,30ms/115VAC atfullload
25ms/230VAC30ms/115VAC atfullload
47~63Hz
79% 81% 82%80%
CH1:5.75~6.75V
3A/115VAC2A/230VAC
COLDSTART 40A/230VAC
<2mA /240VAC
110~150% ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
UL60950-1, TUVEN60950-1 Approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN61000-6-2(EN50082-2)heavyindustrylevel,criteria A
-25~+70 (Refertooutputloadderatingcurve)
20~90%RH non-condensing
-40~+85 ,10~95%RH
0.03%/ (0~50 )on+5Voutput
10~500Hz,5G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
209.3Khrsmin.MIL-HDBK-217F(25 )
199*98*38mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
FileName:RT-125-SPEC2007-03-22
125W TripleOutputSwitchingPowerSupply RT-125 ser i es
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
CURRENTRANGE Note.6
RATEDPOWER Note.6
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
LINEREGULATION Note.4
LOADREGULATION Note.5
ENVIRONMENT
PROTECTION
EMICONDUCTION&RADIATION
SAFETY &
EMC
(Note7)
0.7Kg;20pcs/14Kg/0.8CUFT
88~132VAC/176~264VACselectedbyswitch248~373VDC(Withstand300VACsurgefor5sec.Withoutdamage)
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105
Withstand 300VAC surge input for 5 second
High operating temperature up to 70
Withstand 5G vibration test
High efficiency, long life and high reliability
3 years warranty
long life electrolytic capacitors
Features :
CH1 CH1 CH1 CH1
OUTPUTNUMBER
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved