EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AMERICAS
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
115
www.astecpower.com
Ordering Information
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Connector LPQ152 LPQ153 LPQ154
SK1 PIN 1 INHIBIT -ve INHIBIT -ve INHIBIT -ve
PIN 2 INHIBIT +ve INHIBIT +ve INHIBIT +ve
PIN 3 +12 V +15 V +12 V
PIN 4 No Connection No Connection No Connection
PIN 5 COMMON COMMON COMMON
PIN 6 -SENSE -SENSE -SENSE
PIN 7 +SENSE +SENSE +SENSE
PIN 8 I SHARE I SHARE I SHARE
SK2 PIN 1,2 +12 V +15 V +12 V
PIN 3,4,5 COMMON COMMON COMMON
PIN 6 -12 V -15 V -12 V
PIN 7 POK POK POK
PIN 8 +5 V to +25 V (Float) +5 V to +25 V (Float) +24 V
PIN 9 COMMON (Float) COMMON (Float) COMMON
SK3 TB-1 COMMON COMMON COMMON
TB-2 +5 V +5 V +5 V
SK4 PIN 1 GROUND GROUND GROUND
PIN 3 LINE LINE LINE
PIN 5 NEUTRAL NEUTRAL NEUTRAL
Mating Connectors
(SK4) AC Input: Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK)
PINS: 08-58-0111
(SK2) Aux DC Output/Power fail:
Molex 09-50-8091 (USA)
Molex 09-91-0900 (UK)
PINS: 08-58-0111
(SK1) Remote sense/Remote inhibit:
Molex 51110-0851 (USA)
PINS: 503-94-8100
Astec Connector Kit #70-841-010, includes al of the above.
4.25
(108.0)
1.5
(38.1)
.75 (19.0)
.5625
SK3
8.5
(216.0)
7.4
(188.0)
2.5
(63.5)
.875
(22.25)
SK2
SK4
#6-32 UNC (8 places)
1987654321
5 3 1
SK1
1234
8765
2
4th O/P ADJ
5V O/P ADJ
DO NOT ADJ
Model Output Minimum Maximum Load with Maximum Load with Peak Regulation2Ripple
Number Voltage Load Convection Cooling 30 CFM Forced Air Load1P/P (PARD)3
Vm 05%2±A 03A 22A 51A 2V 5251QPL
Vm 021%3±A 01A 8A 6A 1.V 21
Vm 021%3±A 3A 5.2A 2A 1.V 21-
.xam ,Vm 042%3±A 3A 3A 5.2A 0V 52-5±
Vm 05%2±A 03A 22A 51A 2V 5351QPL
Vm 051%3±A 8A 4.6A 8.4A 1.V 51
Vm 051%3±A 4.2A 2A 6.1A 1.V 51-
.xam ,Vm 042%3±A 3A 3A 5.2A 0V 52-5±
Vm 05%2±A 03A 22A 51A 2V 5451QPL
Vm 021%3±A 01A 8A 6A 1.V 21
Vm 021%3±A 3A 5.2A 2A 1.V 21-
Vm 042%5- /
01+A 5A 5.4A 5.3A 5.V 42
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. 4th output adjustable 5-25 V factory set at 5 V.
5. Minimum loads are required.
Note: -C suffix added to the model number indicates cover option.
Pin Assignments
Notes
1. Specifications subject to change
without notice.
2. All dimensions in inches (mm),
tolerance is ±0.02”.
3. Specifications are for convection
rating at factory settings unless
otherwise stated.
4. Remote inhibit requires an external
5V @ 10mA to activate.
5. Mounting (6-32) maximum insertion
depth is 0.12”.
6. Warranty: 2 year
7. Weight: 1.75 lb. / 0.80 kg
LPQ150 Series