Philips Semiconductors Product specification Three quadrant triacs high commutation GENERAL DESCRIPTION Glass passivated high commutation triacs in a full pack, plastic envelope intended for use in motor control circuits where high static and dynamic dV/dt and high dI/dt can occur. These devices will commutate the full rated rms current at the maximum rated junction temperature, without the aid of a snubber. PINNING - SOT186A PIN BTA208X series B QUICK REFERENCE DATA SYMBOL VDRM IT(RMS) ITSM PARAMETER MAX. MAX. MAX. UNIT BTA208XRepetitive peak off-state voltages RMS on-state current Non-repetitive peak on-state current PIN CONFIGURATION 500B 500 600B 600 800B 800 V 8 65 8 65 8 65 A A SYMBOL DESCRIPTION case 1 main terminal 1 2 main terminal 2 3 gate T2 T1 G 1 2 3 case isolated LIMITING VALUES Limiting values in accordance with the Absolute Maximum System (IEC 134). SYMBOL PARAMETER VDRM Repetitive peak off-state voltages IT(RMS) RMS on-state current ITSM Non-repetitive peak on-state current I2t dIT/dt IGM VGM PGM PG(AV) Tstg Tj I2t for fusing Repetitive rate of rise of on-state current after triggering Peak gate current Peak gate voltage Peak gate power Average gate power CONDITIONS MIN. - full sine wave; Ths 73 C full sine wave; Tj = 25 C prior to surge t = 20 ms t = 16.7 ms t = 10 ms ITM = 12 A; IG = 0.2 A; dIG/dt = 0.2 A/s over any 20 ms period Storage temperature Operating junction temperature MAX. -600 6001 -600 6001 UNIT -800 800 V - 8 A - 65 71 21 100 A A A2s A/s - 2 5 5 0.5 A V W W -40 - 150 125 C C 1 Although not recommended, off-state voltages up to 800V may be applied without damage, but the triac may switch to the on-state. The rate of rise of current should not exceed 6 A/s. September 1997 1 Rev 1.200 Philips Semiconductors Product specification Three quadrant triacs high commutation BTA208X series B ISOLATION LIMITING VALUE & CHARACTERISTIC Ths = 25 C unless otherwise specified SYMBOL PARAMETER CONDITIONS MIN. Visol R.M.S. isolation voltage from all three terminals to external heatsink f = 50-60 Hz; sinusoidal waveform; R.H. 65% ; clean and dustfree Cisol Capacitance from T2 to external f = 1 MHz heatsink TYP. - MAX. UNIT 2500 V - 10 - pF MIN. TYP. MAX. UNIT - 55 4.5 6.5 - K/W K/W K/W MIN. TYP. MAX. UNIT T2+ G+ T2+ GT2- G- 2 2 2 18 21 34 50 50 50 mA mA mA T2+ G+ T2+ GT2- G- VD = 12 V; IGT = 0.1 A IT = 10 A VD = 12 V; IT = 0.1 A VD = 400 V; IT = 0.1 A; Tj = 125 C VD = VDRM(max); Tj = 125 C 0.25 - 31 34 30 31 1.3 0.7 0.4 0.1 60 90 60 60 1.65 1.5 0.5 mA mA mA mA V V V mA THERMAL RESISTANCES SYMBOL PARAMETER CONDITIONS Rth j-hs Thermal resistance junction to heatsink Rth j-a Thermal resistance junction to ambient full or half cycle with heatsink compound without heatsink compound in free air STATIC CHARACTERISTICS Tj = 25 C unless otherwise stated SYMBOL PARAMETER CONDITIONS 2 IGT Gate trigger current IL Latching current IH VT VGT Holding current On-state voltage Gate trigger voltage ID Off-state leakage current VD = 12 V; IT = 0.1 A VD = 12 V; IGT = 0.1 A DYNAMIC CHARACTERISTICS Tj = 25 C unless otherwise stated SYMBOL PARAMETER CONDITIONS MIN. TYP. MAX. UNIT dVD/dt Critical rate of rise of off-state voltage Critical rate of change of commutating current Gate controlled turn-on time VDM = 67% VDRM(max); Tj = 125 C; exponential waveform; gate open circuit VDM = 400 V; Tj = 125 C; IT(RMS) = 8 A; without snubber; gate open circuit ITM = 12 A; VD = VDRM(max); IG = 0.1 A; dIG/dt = 5 A/s 1000 4000 - V/s - 14 - A/ms - 2 - s dIcom/dt tgt 2 Device does not trigger in the T2-, G+ quadrant. September 1997 2 Rev 1.200 Philips Semiconductors Product specification Three quadrant triacs high commutation BT137 Ptot / W 12 BTA208X series B Ths(max) / C 71 = 180 120 10 10 80 8 89 60 6 30 6 73 C 8 90 1 BT137X IT(RMS) / A 98 4 4 107 2 116 0 0 2 4 6 IT(RMS) / A 2 125 10 8 0 -50 Fig.1. Maximum on-state dissipation, Ptot, versus rms on-state current, IT(RMS), where = conduction angle. 1000 50 Ths / C 100 150 Fig.4. Maximum permissible rms current IT(RMS) , versus heatsink temperature Ths. BTA208 ITSM / A 0 25 BT137 IT(RMS) / A 20 dI T /dt limit 15 100 10 I TSM IT T 5 time Tj initial = 25 C max 10 10us 100us 1ms T/s 10ms 0 0.01 100ms Fig.2. Maximum permissible non-repetitive peak on-state current ITSM, versus pulse width tp, for sinusoidal currents, tp 20ms. 80 ITSM / A 1.6 ITSM T 60 VGT(Tj) VGT(25 C) BT136 1.4 time Tj initial = 25 C max 50 10 Fig.5. Maximum permissible repetitive rms on-state current IT(RMS), versus surge duration, for sinusoidal currents, f = 50 Hz; Ths 73C. BT137 IT 70 0.1 1 surge duration / s 1.2 40 1 30 0.8 20 0.6 10 0 1 10 100 Number of cycles at 50Hz 0.4 -50 1000 Fig.3. Maximum permissible non-repetitive peak on-state current ITSM, versus number of cycles, for sinusoidal currents, f = 50 Hz. September 1997 0 50 Tj / C 100 150 Fig.6. Normalised gate trigger voltage VGT(Tj)/ VGT(25C), versus junction temperature Tj. 3 Rev 1.200 Philips Semiconductors Product specification Three quadrant triacs high commutation 3 IGT(Tj) IGT(25 C) BTA208X series B 25 BTA212 Tj = 125 C Tj = 25 C T2+ G+ T2+ GT2- G- 2.5 BT137 IT / A 2 max typ 20 Vo = 1.264 V Rs = 0.0378 Ohms 15 1.5 10 1 5 0.5 0 -50 0 50 Tj / C 100 0 150 Fig.7. Normalised gate trigger current IGT(Tj)/ IGT(25C), versus junction temperature Tj. 3 IL(Tj) IL(25 C) 0 0.5 1 1.5 VT / V 2 2.5 3 Fig.10. Typical and maximum on-state characteristic. 10 TRIAC BT137 Zth j-hs (K/W) with heatsink compound without heatsink compound 2.5 unidirectional 1 2 bidirectional 1.5 0.1 1 P D tp 0.5 t 0 -50 0 50 Tj / C 100 0.01 10us 150 IH(Tj) IH(25C) 1ms 10ms 0.1s 1s 10s tp / s Fig.11. Transient thermal impedance Zth j-hs, versus pulse width tp. Fig.8. Normalised latching current IL(Tj)/ IL(25C), versus junction temperature Tj. 3 0.1ms 1000 TRIAC dIcom/dt (A/ms) BTA208 2.5 100 2 1.5 10 1 0.5 0 -50 0 50 Tj / C 100 1 20 150 60 80 Tj / C 100 120 140 Fig.12. Typical, critical rate of change of commutating current dIcom/dt versus junction temperature. Fig.9. Normalised holding current IH(Tj)/ IH(25C), versus junction temperature Tj. September 1997 40 4 Rev 1.200 Philips Semiconductors Product specification Three quadrant triacs high commutation BTA208X series B MECHANICAL DATA Dimensions in mm Net Mass: 2 g 10.3 max 4.6 max 3.2 3.0 2.9 max 2.8 Recesses (2x) 2.5 0.8 max. depth 6.4 15.8 19 max. max. 15.8 max seating plane 3 max. not tinned 3 2.5 13.5 min. 1 0.4 2 3 M 1.0 (2x) 0.6 2.54 0.9 0.7 0.5 2.5 5.08 1.3 Fig.13. SOT186A; The seating plane is electrically isolated from all terminals. Notes 1. Refer to mounting instructions for F-pack envelopes. 2. Epoxy meets UL94 V0 at 1/8". September 1997 5 Rev 1.200 Philips Semiconductors Product specification Three quadrant triacs high commutation BTA208X series B DEFINITIONS Data sheet status Objective specification This data sheet contains target or goal specifications for product development. Preliminary specification This data sheet contains preliminary data; supplementary data may be published later. Product specification This data sheet contains final product specifications. Limiting values Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of this specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification. Philips Electronics N.V. 1997 All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, it is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent or other industrial or intellectual property rights. LIFE SUPPORT APPLICATIONS These products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale. September 1997 6 Rev 1.200