NOT RECOMMENDED FOR NEW DESIGN MURB1610CT / MURB1620CT 16A SURFACE MOUNT SUPER-FAST RECTIFIER Features * * * * * Glass Passivated Die Construction Super-Fast Recovery Times for High Efficiency Surge Overload Rating to 100A Peak Low Reverse Leakage Current Lead Free Finish, RoHS Compliant (Note 3) E 2 A G 4 H Mechanical Data * * * * * * * * 2 Dim Min Max A 9.65 10.69 B 14.60 15.88 C 0.51 1.14 D 2.29 2.79 J B 1 D PAK 3 2 Case: D PAK Case Material: Molded Plastic. UL Flammability Classification Rating 94V-0 Moisture Sensitivity: Level 1 per J-STD-020C Terminals: Finish - Tin. Solderable per MIL-STD-202, Method 208 Polarity: See Diagram Marking Information: See Page 3 Ordering Information: See Page 3 Weight: 1.7 grams (approximate) M D K C L PIN 1 PIN 2 & 4 PIN 3 E 4.37 4.83 G 1.14 1.40 H 1.14 1.40 9.25 J 8.25 K 0.30 0.64 L 2.03 2.92 M 2.29 2.79 All Dimensions in mm Maximum Ratings and Electrical Characteristics @TA = 25C unless otherwise specified Single phase, half wave, 60Hz, resistive or inductive load. For capacitive load, derate current by 20%. Characteristic Peak Repetitive Reverse Voltage Working Peak Reverse Voltage DC Blocking Voltage (Note 4) Symbol VRRM VRWM VR MURB1610CT MURB1620CT Unit 100 200 V RMS Reverse Voltage VR(RMS) 70 140 V Average Rectified Output Current @ TC = 125C Non-Repetitive Peak Forward Surge Current 8.3ms Single Half Sine-Wave Superimposed on Rated Load IO 16 A IFSM 100 A Forward Voltage VFM 0.975 V IRM 5.0 250 A trr 30 ns CT 85 pF RJC 1.5 C/W Tj, TSTG -65 to +150 C Peak Reverse Current at Rated DC Blocking Voltage (Note 4) Maximum Recovery Time (Note 1) Typical Total Capacitance (Note 2) Typical Thermal Resistance Junction to Case Operating and Storage Temperature Range Notes: 1. 2. 3. 4. @ IF = 8.0A @ TA = 25C @ TA = 150C Measured with IF = 0.5A, IR = 1.0A, Irr = 0.25A. Measured at 1.0 MHz and applied reverse voltage of 4.0V DC. RHS revision 13.2.2003. Glass and high temperature solder exemptions applied, see EU Directive Annex Notes 5 and 7. Short duration pulse test used to minimize self-heating effect. DS14005 Rev. 6 - 3 1 of 3 www.diodes.com MURB1610CT/MURB1620CT (c) Diodes Incorporated NOT RECOMMENDED FOR NEW DESIGN IF, INSTANTANEOUS FORWARD CURRENT (A) I(AV), AVERAGE FORWARD CURRENT (A) 20 16 12 8 4 0 100 125 150 100 10 1.0 T j = 25C 0.1 0.2 175 TC, CASE TEMPERATURE (C) Fig. 1 Forward Current Derating Curve 1.4 400 125 CT, TOTAL CAPACITANCE (pF) IFSM, PEAK FORWARD SURGE CURRENT (A) 1.0 VF, INSTANTANEOUS FORWARD VOLTAGE (V) Fig. 2 Typical Forward Characteristics per Element 150 100 75 50 25 100 10 0 1 10 100 0.1 1.0 10 100 VR, REVERSE VOLTAGE (V) Fig. 4 Typical Total Capacitance, per Element NUMBER OF CYCLES AT 60Hz Fig. 3 Max Non-Repetitive Surge Current IR , INSTANTANEOUS REVERSE CURRENT (mA) 0.6 100 10 1.0 0.1 0.01 0 40 80 120 PERCENT OF RATED PEAK REVERSE VOLTAGE (%) Fig. 5 Typical Reverse Characteristics DS14005 Rev. 6 - 3 2 of 3 www.diodes.com MURB1610CT/MURB1620CT (c) Diodes Incorporated NOT RECOMMENDED FOR NEW DESIGN Ordering Information (Note 5 & 6) Device MURB1610CT-13 MURB1620CT-13 Notes: Packaging 2 D PAK 2 D PAK Shipping 800/Tape & Reel 800/Tape & Reel 5. For packaging details, go to our website at http://www.diodes.com/datasheets/ap02007.pdf. 6. Unit mounted on PC board with 5.0 mm2 (0.013 mm thick) copper pad as heat sink. Marking Information YWW MURB16X0CT MURB16X0CT = Product type marking code eg: MURB1610CT = Manufacturers' code marking YWW = Date code marking Y = Last digit of year ex: 2 for 2002 WW = Week code 01 to 52 IMPORTANT NOTICE DIODES INCORPORATED MAKES NO WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, WITH REGARDS TO THIS DOCUMENT, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION). Diodes Incorporated and its subsidiaries reserve the right to make modifications, enhancements, improvements, corrections or other changes without further notice to this document and any product described herein. Diodes Incorporated does not assume any liability arising out of the application or use of this document or any product described herein; neither does Diodes Incorporated convey any license under its patent or trademark rights, nor the rights of others. Any Customer or user of this document or products described herein in such applications shall assume all risks of such use and will agree to hold Diodes Incorporated and all the companies whose products are represented on Diodes Incorporated website, harmless against all damages. Diodes Incorporated does not warrant or accept any liability whatsoever in respect of any products purchased through unauthorized sales channel. Should Customers purchase or use Diodes Incorporated products for any unintended or unauthorized application, Customers shall indemnify and hold Diodes Incorporated and its representatives harmless against all claims, damages, expenses, and attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized application. Products described herein may be covered by one or more United States, international or foreign patents pending. Product names and markings noted herein may also be covered by one or more United States, international or foreign trademarks. LIFE SUPPORT Diodes Incorporated products are specifically not authorized for use as critical components in life support devices or systems without the express written approval of the Chief Executive Officer of Diodes Incorporated. As used herein: A. Life support devices or systems are devices or systems which: 1. are intended to implant into the body, or 2. support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in significant injury to the user. B. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or to affect its safety or effectiveness. Customers represent that they have all necessary expertise in the safety and regulatory ramifications of their life support devices or systems, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of Diodes Incorporated products in such safety-critical, life support devices or systems, notwithstanding any devices- or systems-related information or support that may be provided by Diodes Incorporated. Further, Customers must fully indemnify Diodes Incorporated and its representatives against any damages arising out of the use of Diodes Incorporated products in such safety-critical, life support devices or systems. Copyright (c) 2010, Diodes Incorporated www.diodes.com DS14005 Rev. 6 - 3 3 of 3 www.diodes.com MURB1610CT/MURB1620CT (c) Diodes Incorporated