GU 2 Form A Current Limiting (AQW210HL) TESTING Two output type with current limiting and reinforced insulation GU 2 Form A Current Limiting (AQW210HL) FEATURES 6.4 .252 3.2 .126 9.86 .388 6.4 .252 2.9 .114 9.86 .388 mm inch 1 8 2 7 3 6 4 5 RoHS compliant 6. High sensitivity and high speed response. Can control max. 0.12 A load current with 5 mA input current. This enables fast operation speed of typ. 0.5 ms 7. Low-level off state leakage current 1. Current Limiting Function To control an over current from flowing, the current limit function has been realized. It keeps an output current at a constant value when the current reaches a specified current limit value. 2. Enhances the capability of surge resistance between output terminals The current limit function controls the ON time surge current to enhance the capability of surge resistance between output terminals. 3. Reinforced insulation of 5,000 V More than 0.4 mm internal insulation distance between inputs and outputs. Con-forms to EN41003, EN60950 (reinforced insulation). 4. Applicable for 2 Form A use as well as two independent 1 Form A use. 5. Controls low-level analog signals TYPICAL APPLICATIONS * Telephone equipment * Modem TYPES Part No. Output rating* I/O isolation voltage AC/DC dual use Reinforced 5,000 V AC Package Load voltage Load current 350 V 100 mA Through hole terminal Tube packing style DIP8-pin AQW210HL Packing quantity Surface-mount terminal AQW210HLA Tape and reel packing style Picked from the Picked from the 1/2/3/4-pin side 5/6/7/8-pin side AQW210HLAX AQW210HLAZ Tube Tape and reel 1 tube contains: 50 pcs. 1 batch contains: 500 pcs. 1,000 pcs. *Indicate the peak AC and DC values. Note: The surface mount terminal shape indicator "A" and the packing style indicator "X" or "Z" are not marked on the device. RATING 1. Absolute maximum ratings (Ambient temperature: 25C 77F) Input Item LED forward current LED reverse voltage Peak forward current Power dissipation Load voltage (peak AC) Symbol IF VR IFP Pin VL AQW210HL(A) 50 mA 5V 1A 75 mW 350 V Output Continuous load current IL 0.1 A (0.12 A) Pout PT Viso 800 mW 850 mW 5,000 V AC -40C to +85C -40F to +185F Power dissipation Total power dissipation I/O isolation voltage Temperature limits ASCTB56E 201201-T Operating Storage Topr Tstg Panasonic Corporation Remarks f = 100 Hz, Duty factor = 0.1% Peak AC, DC ( ): in case of using only 1 channel Non-condensing at low temperatures -40C to +100C -40F to +212F Automation Controls Business Unit industrial.panasonic.com/ac/e GU 2 Form A Current Limiting (AQW210HL) 2. Electrical characteristics (Ambient temperature: 25C 77F) Item Symbol Typical Maximum Minimum Typical Minimum Typical LED operate current Input LED turn off current LED dropout voltage AQW210HL(A) 1.2 mA 3.0 mA 0.4 mA 1.1 mA 1.25 (1.14 V at IF = 5 mA) 1.5 V IFon IFoff VF Condition IL = Max. IL = Max. IF = 50 mA IF = 5 mA IL = Max. Within 1 s on time IF = 0 mA VL = Max. IF = 5 mA 20 Typical On resistance Ron Maximum 25 Output Off state leakage current Maximum ILeak 1A Current limit Typical -- 0.18 A 0.5 ms Typical Maximum Typical Maximum Typical Maximum Minimum Turn on time* Transfer characteristics Turn off time* I/O capacitance Initial I/O isolation resistance Ton IF = 5 mA IL = Max. 2.0 ms 0.08 ms Toff IF = 5 mA IL = Max. 1.0 ms 0.8 pF Ciso f = 1 MHz VB = 0 V 1.5 pF 1,000 M Riso 500 V DC *Turn on/Turn off time Input 90% 10% Output Ton Toff RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper device operation and resetting. Item Input LED current Symbol IF Recommended value 5 to 10 Unit mA For Dimensions. For Schematic and Wiring Diagrams. For Cautions for Use. These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation technical representative. For more information. REFERENCE DATA 1. Load current vs. ambient temperature characteristics 2. On resistance vs. ambient temperature characteristics 3. Turn on time vs. ambient temperature characteristics Allowable ambient temperature: -40C to +85C -40F to +185F Measured portion: between terminals 5 and 6, 7 and 8; LED current: 5 mA; Load voltage: Max. (DC) Continuous load current: Max.(DC) LED current: 5 mA; Load voltage: Max.(DC); Continuous load current: Max.(DC) 50 150 Using only 1 channel 100 Using 2 channels 3 2.5 40 Turn on time, ms On resistance, Load current, mA 200 30 20 2 1.5 1 50 10 0 -40 -20 0 20 40 60 80 85 100 Ambient temperature, C Panasonic Corporation 0 0.5 -40 -20 0 20 40 60 80 85 0 -40 -20 Ambient temperature, C Automation Controls Business Unit industrial.panasonic.com/ac/e 0 20 40 60 80 85 Ambient temperature, C ASCTB56E 201201-T GU 2 Form A Current Limiting (AQW210HL) 4. Turn off time vs. ambient temperature characteristics 5. LED operate current vs. ambient temperature characteristics 6. LED turn off current vs. ambient temperature characteristics LED current: 5 mA; Load voltage: Max.(DC); Continuous load current: Max.(DC) Load voltage: Max.(DC); Continuous load current: Max.(DC) Load voltage: Max.(DC); Continuous load current: Max.(DC) 5 Turn off time, ms 0.25 0.2 0.15 0.1 4 3 2 4 3 2 1 0.05 0 5 LED turn off current, mA LED operate current, mA 0.3 -40 -20 0 20 40 60 1 0 80 85 -40 -20 0 0 20 40 60 80 85 Ambient temperature, C Ambient temperature, C -40 -20 0 20 40 60 80 85 Ambient temperature, C 7. LED dropout voltage vs. ambient temperature characteristics 8. Current vs. voltage characteristics of output at MOS portion 9. Off state leakage current vs. load voltage characteristics LED current: 5 to 50 mA Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Ambient temperature: 25C 77F 140 120 100 80 60 40 20 -5 -4 -3 -2 -1 1.4 1.3 1.2 1.0 0 1 2 3 4 -20 Voltage, V -40 -60 -80 -100 -120 -140 50mA 30mA 20mA 10mA 5mA 1.1 -40 -20 0 20 40 60 80 85 Ambient temperature, C Off state leakage current, A Current, mA LED dropout voltage, V 1.5 5 10 10 10 10 -3 -6 -9 -12 0 20 40 60 80 100 Load voltage, V 10. Turn on time vs. LED forward current characteristics 11. Turn off time vs. LED forward current characteristics 12. Output capacitance vs. applied voltage characteristics Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: Max.(DC); Continuous load current: Max.(DC); Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Load voltage: Max.(DC); Continuous load current: Max.(DC); Ambient temperature: 25C 77F Measured portion: between terminals 5 and 6, 7 and 8; Frequency: 1 MHz; Ambient temperature: 25C 77F 3 50 Output capacitance, pF 0.2 Turn off time, ms Turn on time, ms 2.5 2 1.5 0.15 0.1 1 0.05 10 20 30 40 50 60 0 LED forward current, mA 0 30 20 10 0.5 0 40 10 20 30 40 50 0 60 0 10 20 30 40 Applied voltage, V LED forward current, mA What is current limit This safety feature protects circuits downstream of the PhotoMOS against over-current. But, if the current-limiting feature is used longer than the specified time, the PhotoMOS can be destroyed. Therefore, set the output loss to the max. rate or less. * Comparison of output voltage and output current characteristics V-I Characteristics Output current When a load current reaches the specified output control current, a current limit function works against the load current to keep the current a constant value. The current limit circuit built into the PhotoMOS thus controls the instantaneous load current to effectively ensure circuit safety. Output voltage ASCTB56E 201201-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e 50