General Purpose Relays Safety Relay SR4 D/M I 4 pole safety relay with either 2 NO+2 NC or 3 NO+1 NC contacts I Forcibly guided contacts according to EN 50205 I Rated current 8 A I Very small outlines I RoHS compliant (Directive 2002/95/EC) as per product date code 0407 Applications Emergency shut-off, machine control, elevator and escalator control, light barrier control F0244-A Approvals V REG.-Nr. 40005334, Z E214024, T 968/EL 230.00/03 Technical data of approved types on request Contact data Contact configuration Contact set Type of interruption Rated current Rated voltage / max.switching voltage AC Maximum breaking capacity AC Utilization class (AC-15) acc. IEC 60947-5-1 NO contact NC contact Contact material Minimum contact load Contact resistance 3 N/O contacts and 1 N/C contact or 2 N/O contacts and 2 N/C contacts single contact, forcibly guided type A according to EN 50205 micro disconnection 8A 240/400 VAC 2000 VA Ie 3 A / Ue 250 VAC (inrush 30 A) Ie 1.5 A / Ue 250 VAC (inrush 15 A) AgSnO2 10 mA / 5 V w 100 mOhm / 1 A / 24 VDC w 20 Ohm / 10 mA / 5 VDC Mechanical endurance 10x106 cycles Rated frequency of operation with / without load 6 min-1 / 150 min-1 Coil data Rated coil voltage range DC coil Coil power DC coil Operative range 5...110 VDC appr. 800 mW 2 Coil versions, DC-coil Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 005 5 3.8 0.5 31+10% 806 006 6 4.5 0.6 45+10% 800 009 9 6.8 0.9 101+10% 802 012 12 9.0 1.2 180+10% 800 015 15 11.3 1.5 281+10% 801 018 18 13.5 1.8 405+10% 800 021 21 15.8 2.1 551+10% 800 024 24 18.0 2.4 720+10% 800 036 36 27.0 3.6 1620+10% 800 040 40 30.0 4.0 2000+10% 800 048 48 36.0 4.8 2880+10% 800 060 60 45.0 6.0 4500+10% 800 085 85 63.8 8.5 9031+10% 800 110 110 82.5 11.0 15125+10% 800 All figures are given for coil without preenergization, at ambient temperature +23C 1 Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the `Schrack' section. Specifications subject to change. General Purpose Relays Safety Relay SR4 D/M (Continued) PCB layout / terminal assignment Other coil voltages on request Bottom view on solder pins Insulation > 100x106 Ohm 4000 Vrms 1500 Vrms 2500 Vrms W 10 / 10 mm W 3 / 3.5 mm W 1.3 / 3.5 mm W IIIa CTI 250 Insulation resistance coil-contact circuit Dielectric strength coil-contact circuit open contact circuit adjacent contact circuits Clearance / creepage coil-contact circuit adjacent contact circuits adjacent contact circuits (UL840) Material group of insulation parts Tracking index of relay base Insulation to IEC 60664-1 Type of insulation coil-contact circuit open contact circuit adjacent contact circuits Rated insulation voltage Pollution degree Rated voltage system Overvoltage category Insulation to EN 50178 Type of insulation coil-contact circuit adjacent contact circuits S0413-BC 2 NO and 2 NC contacts reinforced functional basic 250 V 2 230/400 V III S0413-BB reinforced basic 3 NO and 1 NC contacts Other data RoHS - Directive 2002/95/EC compliant as per product date code 0407 Ambient temperature range -25...+70C Vibration resistance (function) NO / NC contact > 10 / 2 g, 10....200 Hz Shock resistance (function) NO / NC contact > 10 / 2 g, 11 ms half sine Category of protection RT III 1) Resistance to soldering heat 260C / 5 s Relay weight 16 g Packaging unit 10 pcs 1) S0413-BA please contact technical support for washing parameters Dimensions S0412-BH Product key S R 4 4 Type Contact configuration D 2 NO + 2 NC contacts M 3 NO + 1 NC contacts Contact material 4 AgSnO2 Coil Coil code = rated coil voltage (e.g. 024=24 VDC) Other types on request 2 Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the `Schrack' section. Specifications subject to change. General Purpose Relays Safety Relay SR4 D/M (Continued) Product key SR4D4005 SR4D4006 SR4D4009 SR4D4012 SR4D4018 SR4D4021 SR4D4024 SR4D4036 SR4D4040 SR4D4048 SR4D4060 SR4D4085 SR4D4110 SR4M4005 SR4M4006 SR4M4009 SR4M4012 SR4M4018 SR4M4021 SR4M4024 SR4M4036 SR4M4040 SR4M4048 SR4M4060 SR4M4085 SR4M4110 Type 4 pole safety relay Contact configuration 2 NO + 2 NC contacts Contact material AgSnO2 3 NO + 1 NC contacts Coil 5 VDC 6 VDC 9 VDC 12 VDC 18 VDC 21 VDC 24 VDC 36 VDC 40 VDC 48 VDC 60 VDC 85 VDC 110 VDC 5 VDC 6 VDC 9 VDC 12 VDC 18 VDC 21 VDC 24 VDC 36 VDC 40 VDC 48 VDC 60 VDC 85 VDC 110 VDC Part number 7-1415054-1 8-1415054-1 9-1415054-1 0-1415055-1 1-1415055-1 2-1415055-1 3-1415055-1 4-1415055-1 5-1415055-1 6-1415055-1 7-1415055-1 8-1415055-1 9-1415055-1 5-1415053-1 6-1415053-1 7-1415053-1 8-1415053-1 9-1415053-1 0-1415054-1 4-1415053-1 1-1415054-1 2-1415054-1 3-1415054-1 4-1415054-1 5-1415054-1 6-1415054-1 3 Datasheet Rev. EK1 Issued 2005/11 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' at schrackrelays.com in the `Schrack' section. Specifications subject to change.