INTEGRATED CIRCUITS DIVISION
www.ixysic.com
2R03
CPC1020N
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Ratings Units
Blocking Voltage 30 VP
Input Power Dissipation 175 mW
Input Control Current 50 mA
Peak (10ms) 1 A
Reverse Input Voltage 5 V
Total Power Dissipation 2400 mW
Isolation voltage, Input to Output 1500 Vrms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 3.33 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
Load Current
Continuous 1IF=2mA IL- - 1.2 ADC
Peak t < 10ms ILPK --3A
On-Resistance 2IL=1A RON - 0.116 0.25
Off-State Leakage Current VL=30VPILEAK --1A
Switching Speeds
Turn-On IF=5mA, VL=10V ton - 0.48 3 ms
Turn-Off toff - 0.65 3
Output Capacitance VL=15V, f=1MHz COUT -70 -pF
Input Characteristics
Input Control Current to Activate IL=1A IF- 0.13 2 mA
Input Control Current to Deactivate - IF0.1 - - mA
Input Voltage Drop IF=5mA VF0.9 1.2 1.4 V
Reverse Input Current VR=5V IR- - 10 µA
Input/Output Characteristics
Capacitance, Input to Output - CI/O -3 -pF
1 Load current derates linearly from 1.2A @ 25oC to 0.58A @85oC.
2 Measurement taken within 1 second of on-time.
Electrical Characteristics @ 25ºC
ESD Rating (Human Body Model)
1000 Volts
ESD Rating