5 Power PCB Relay G2R
Latching dual coil type - Set coil
Latching dual coil type - Reset coil
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C (73°F).
■Characteristics
Note: Data shown are of initial value.
Rated voltage
(VDC)
Rated current
(mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature
OFF
Armature
ON
% of rated voltage
3 227 10.80 0.026 0.052 70% max. 70% max. 110% max.
at 70°C
(158°F)
Approx. 850
5 167 30 0.073 0.146
6 138 43.50 0.104 0.208
12 70.60 170 0.42 0.83
24 34.60 694 1.74 3.43
Rated voltage
(VDC)
Rated current
(mA)
Coil
resistance
(Ω)
Coil inductance
(ref. value) (H)
Pick-up
voltage
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
Armature
OFF
Armature
ON
% of rated voltage
3 200 15 0.001 0.002 70% max. 70% max. 110% max.
at 70°C
(158°F)
Approx. 600
5 119 42 0.003 0.006
6 100 60 0.005 0.009
12 50 240 0.018 0.036
24 25 960 0.079 0.148
Item Non-latching Latching
Contact resistance 100 mΩ
Operate (set) time 15 ms. max. 20 ms max.
Release (reset) time AC: 10 ms max.; DC: 5 ms max. 20 ms max.
Bounce time Operate --- Mean value approx. 3 ms
Release --- Mean value approx. 8 ms
Operating frequency Mechanical 18,000 operations/hour
Electrical 1,800 operations/hour (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 5,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute across contacts of same pole
3,000 VAC, 50/60 Hz for 1 minute between contact sets, 2-pole non-latching
1,000 VAC, 50/60 Hz for 1 minute between set and reset coils of dual coil latching
Vibration Mechanical durability 10 to 55 Hz; 1.50 mm (0.06) double amplitude
Malfunction durability 10 to 55 Hz; 1.50 mm (0.06) double amplitude
Shock Mechanical durability 1,000 m/s2 (approx. 100G)
Malfunction durability 200 m/s2 (approx. 20 G) when energized
100 m/s2 (approx. 10 G) when de-energized
500 m/s2 (approx. 50 G) at set
100 m/s2 (approx. 10 G) at reset
Ambient temperature -40 to 70°C (-40 to 158°F)
Humidity 35% to 85% RH
Service life Mechanical AC: 10,000,000 operations min.
DC: 20,000,000 operations min.
(at 18,000 operations/hour)
10,000,000 operations min.
(at 18,000 operations/hour)
Electrical See “Characteristics Data”