Nominal operating voltage
Nominal operating current
Coil resistance ()
Nominal operating power (mW)
5
30
166.7
4.5
33.3
135
150
3
50
60
Nominal operating voltage
Nominal operating current
Coil resistance ()
Nominal operating power (mW)
5
40
125
4.5
44.4
101.3
200
3
66.7
45
4
WA optical
switch
ORIGINAL POLARIZED
ACTUATOR CONSTRUCTION
FEATURES
• Small size, Low height
31 mm (L) × 16 mm (W) × 9 mm (H)
1.220 inch (L) × .630 inch (W) × .354 inch (H)
• Low Insertion Loss
Achieved 1dB max. insertion loss (Typ. 0.5dB)
• Latching Operation
Latching operation is realized by “Original polarized actuator
construction”
APPLICATIONS
• OADM
• Protection switching (WDM. CATV, FTTH)
• Network monitoring
• Optical measuring instrument
ORDERING INFORMATION
FORM
SPECIFICATIONS COIL DATA (at 20°C 68°F)
<1 coil latching>
<2 coil latching>
AWAP
Switch type
0: 12
1: 220: 1,310±20nm
1: 1,550±20nm
2: 1,310/1,550nm±20nm
1: 1 coil latching
2: 2 coil latching 2: SC/AdPC
3: MU/AdPC 1: 3V DC
6: 4.5V DC
9: 5V DC
Wavelength Operation type Connector type Nominal coil voltage
12 type 22 type
Vibration
resistance
Shock
resistance
Insertion loss*1
Isolation*2
Return loss*2
P.D.L.*2
Optical input power
Mechanical eudurance
Functional
Destructive
Functional
Destructive
Switching time
Fiber type
Operation temperature
Storage temperature
Weight
Max. 1.0dB
Min. 60dB
Min. 50dB
Max. 0.1dB
Max. 100mW (20dBm)
Min. 10M opes.
10 to 55Hz double amplitude 0.75mm
10 to 55Hz double amplitude 1.52mm
Min. 200m/s2
Min. 500m/s2
Max. 10ms
SMF (9.5/125/900)
–40°C to +70°C –40°F to +158°F
–40°C to +70°C –40°F to +158°F
Approx. 11g
Notes: *1. Connectors are excluded. Add up to 0.2dB typ. for each
connector. Add 0.3dB typical over temperature range.
*2. Connectors are excluded.
* For operation, more than 20ms pulse with nominal voltage +20%/–5%
V is recommended.
5
DIMENSIONS
12, 1 coil latching
12, 2 coil latching
22, 1 coil latching
22, 2 coil latching
12
22
PC board pattern (Tolerance: ±0.1 ±.004)
Optical signal I/O and
coil impress direction indication diagram
1
4
31
2
+
Port 3 (Set)
Port 2 (Reset)
Port 1 Output
mm inch
Input
4
31
2
+
+
Port 3 (Set)
Port 2 (Reset)
Port 1 OutputInput
++
4
31
2
Port 3
Port 2Port 1
Port 4
OutputInput
+4
31
2
Port 3
Port 2Port 1
Port 4
OutputInput
31.00±0.3
1.220±.012
50.00±0.3
1.969±.012
16.00±0.3
.630±.012
16.00±0.3
.630±.012
6.10±0.3
.240±.012
6.10±0.3
.240±.012
26.00±0.3
1.024±.012
26.00±0.3
1.024±.012
26.00
1.024 5.20
.205
1.05 dia.
.041 dia.
3.25±0.3
.128±.012
0.60±0.1
.024±.004
5.20±0.3
.205±.012
0.30±0.1
.012±.004
3.00±0.3
.118±.012
3.00±0.3
.118±.012
9.00±0.3
.354±.012
9.00±0.3
.354±.012
1m+0.1m
0
3.281ft+.328ft
0
1m+0.1m
0
3.281ft+.328ft
0
31.00±0.3
1.220±.012
50.00±0.3
1.969±.012
0.30±0.1
.012±.004 3.25±0.3
.128±.012
0.60±0.1
.024±.004
5.20±0.3
.205±.012
Reset condition (Bottom view)
Reset condition (Bottom view)
Reset condition (Bottom view)
Reset condition (Bottom view)
Reset
Set
Port1Port2
Port4Port3
Port1Port3
Port4Port2
Reset
Set
Port1Port2
Port4Port3
Port1Port3
Port4Port2
6
PERFORMANCE TEST DATA
A: Basic characteristic
B: Life tests
C: Environmental tests (Mechanical stress)
D: Environmental tests (Temperature & Humidity stress)
Test item Test target value and condition Referential standard Number of
samples Result
1. Set voltage Less than nominal voltage JIS C 5442 4.6
Method A 20 Good
2. Reset voltage Less than nominal voltage JIS C 5442 4.6
Method A 20 Good
3. Set time Less than 10ms
(without diode) JIS C5931 5.5 20 Good
4. Reset time Less than 10ms
(without diode) JIS C5931 5.5 20 Good
5. Insertion loss Less than 1.0 dB IEC 61300-2-4
JIS C5901 6.2 20 Good
6. Isolation More than 60 dB IEC 61300-3-9
JIS C5901 6.7 20 Good
7. Return loss More than 50 dB IEC 61300-3-6
JIS C5901 6.5 20 Good
8. P.D.L. Less than 0.1 dB IEC 61300-3-2
JIS C5901 6.3 20 Good
Test item Test target value and condition Referential standard Number of
samples Result
1. Optical input power 100mW, 2 min. Telcordia GR-1073 6 Good
2. Mechanical life 1 × 107, 180/min. JIS C 5442 7.1.2 6 Good
Test item Test target value and condition Referential standard Number of
samples Result
1. Vibration resistance 10 to 55Hz (1.52mm .060inch±10%) in 4 minutes.
2 hours in each of three directions. Telcordia GR-1073 3 Good
2. Shock resistance 200m/s2, sine half-wave pulse 11ms
5 times in each six directions. IEC 61300-2-9
JIS C 5901 7.2 3 Good
3. Cable retention Tensile strength: 450g 15.873oz, 0.4mm/sec.
1 min. Telcordia GR-1073 3 Good
4. Side pull Tensile strength: 230g 8.113oz, at an angle of 90°
5 sec. Telcordia GR-1073 3 Good
Test item Test target value and condition Referential standard Number of
samples Result
1. Solder heat test Solder Temp .: 250°C 482°F
Solder Time: 3 sec. JIS C 5442 5.5 3 Good
2. High temperature storage 85±2°C 185±35.6°F, 2000 hours Telcordia GR-1221 11 Good
3. Low temperature storage –40°C –40°F, 2000 hours 11 Good
4. Temprature cycling –40°C –40°F 85°C 185°F,
500 cycles Telcordia GR-1221 11 Good
5. Damp heat 85°C 185°F 85%RH, 1000 hours Telcordia GR-1221 11 Good
6. Humidity cycle
25°C 77°F 95%RH65°C 149°F 95%RH–10°C 14°F25°C 77°F
100cycles MIL-STD-202E
Method 106
JIS C 5442 6.5 6 Good
7. Compound stress
Random Vibration;
10 to 500 Hz, 98m/s2 (Ave), 294m/s2 (Peak)
Thermal Shock;
–55°C –67°F (30min) 85°C 185°F (30min)
De-energied, 10cyc.
JIS C 5442 6.3 3 Good
Telcordia GR-1221
7
A-1, 2
Set voltage and reset voltage
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=20
2. Test conditions:
(1) Ambient temperature and humidity: 25°C 77°F, 50 % RH
a) Set voltage b) Reset voltage
A-3, 4
Set time and reset time
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=20
2. Test conditions:
(1) Ambient temperature and humidity: 25°C 77°F, 50 % RH
a) Set time
Set Voltage (V)
Min. : 2.710
Max. : 3.250
Ave. : 2.966
σ n-1: 0.132
Set Time (ms)
Min. : 5.120
Max. : 7.220
Ave. : 6.143
σ n-1: 0.490
Min. : 2.260
Max. : 3.340
Ave. : 2.913
σ n-1: 0.281
Reset Voltage (V)
b) Reset time
Min. : 4.040
Max. : 6.840
Ave. : 5.609
σ n-1: 0.674
Reset Time (ms)
2.5 2.6 2.7 2.8 2.9 3.0 3.1 3.2 3.3 3.4
0
2
4
6
8
10
2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8
0
2
4
6
8
10
4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5
2
0
4
6
8
10
3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
0
2
4
6
8
10
A-5, 6
Insertion loss and isolation
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=20
2. Test conditions:
(1) Ambient temperature and humidity: 25°C 77°F, 50 % RH
(2) Measuring method see specification sheet;
a) Insertion loss b) Isolation
Insertion loss (dB)
Min. : 0.070
Max. : 0.728
Ave. : 0.379
σ n-1: 0.161
Min. : 84.640
Max. : 115.220
Ave. : 98.251
σ n-1: 8.987
Isolation (dB)
0.0 0.2 0.4 0.6 0.8 1.0 1.2
0
30
10
20
60 70 80 90 100 110 120 130 140
0
30
10
20
8
A-7, 8
Return loss and P.D.L.
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=20
2. Test conditions:
(1) Ambient temperature and humidity: 25°C 77°F, 50 % RH
(2) Measuring method see specification sheet;
a) Return loss
Return loss (dB)
b) P.D.L.
P.D.L. (dB)
Min. : 55.426
Max. : 71.140
Ave. : 63.760
σ n-1: 3.954
Min. : 0.005
Max. : 0.054
Ave. : 0.032
σ n-1: 0.012
50 55 60 65 70 75 80 85 90
0
30
10
20
0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.080.09 0.10
0
30
10
20
B-1
Optical input power
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=6
2. Test conditions:
(1) Optical input power ; 100 mW
(2) Testing time ; 2 min.
3. Test results:
No abnormality was observed for all samples after test.
B-2
Mechanical life test
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=6
2. Test conditions:
(1) Coil voltage ; 4.5VDC (Nominal voltage)
(2) Cycle Rate ;
10 Hz (On:OFF=0.05s:0.05s)
(3)
Ambient temperature and humidity
; 25°C 77°F, 50 % RH
(4) Number of operations ; 1 × 107 operations
3. Test results:
No abnormality was observed for all samples after 1107 operations.
C-1
Vibration resistance test (Functional)
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=3
2. Test conditions:
(1) Frequency ; 10 to 55 Hz
(2) Double amplitude ; 0.75 mm .030 inch
(3) Coil ; De-energized
(4) Detection level ;
Optical power change : less than 20%
(5)
Vibration application directions
; 2 hours each against 3 directions
3. Test results:
No abnormality was observed during and after test.
43
5
6
2
1
4
3
direction ; 1 2
3 4
5 6
C-2
Mechanical shock test (Functional)
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=3
2. Test conditions:
(1) Peak acceleration ; 200 m/s2
(2)
Corresponding duration of the pulse
; 11 ms
(3) Number of shock applications ; 5 times each
(4) Coil ; De-energized
(5) Detection level ;
Optical power change : less than 20%
(6) Shock application directions ; 6 directions
3. Test results:
No abnormality was observed during and after test.
2
156
9
C-3
Cable retention
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=3
2. Test conditions:
(1) Tensile strength ; 450g 15.873oz
(2) Rate ; 0.4mm .016inch/sec.
(3) The testing time ; 1 min.
(4) Coil ; De-energized
(5) Check item ; Physical damage and optical characteristic
(6) Tensile application directions
3. Test results:
No abnormality was observed after test.
C-4
Cable side pull
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=3
2. Test conditions:
(1) Tensile strength ; 230g 8.113oz
(2) Angle ; 90°
(3) The time applied ; 5 sec.
(4) Check item ; Physical damage and optical characteristic
Measure the insertion loss after the load is applied for at least 5 seconds.
Remove the load, and after 10 seconds remeasure the loss.
(5) Tensile application directions
3. Test results:
No abnormality was observed after test.
10 cm
3.937 inch
pull
Component housing
D-1
Solder heat test
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=3
2. Test conditions:
(1) Solder temperature ; 400 ± 5°C 752 ± 41°F
(2) Soldering time ; 3 ± 0.5 S
(3) Solder ; Sn 96.5 % , Ag 3 % , Cu 0.5 %
(4) Test method ; Switch terminals are inserted into double
sided through-hole PCB.
Each terminal is applied heat stress by
sordering iron.
3. Test results:
No abnormality was observed for all samples after the test.
D-2
High temperature storage
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=11
2. Test conditions:
(1) Ambient temperature ; 85±2°C 185 ± 35.6°F
(2) Exposure period ; 2000 hours (14 days)
3. Test results:
No abnormality was observed for all samples after 2000 hours.
D-3
Low temperature storage
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=11
2. Test conditions:
(1) Ambient temperature ; –40±2°C –40±35.6°F
(2) Exposure period ; 2000 hours
3. Test results:
No abnormality was observed for all samples after 2000 hours.
D-4
Temperature cycle
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=11
2. Test conditions:
(1) Low temperature ; –40°C –40°F
(2) High temperature ; 85°C 185°F
(3) Number of cycles ; 500 cycles
(4) Coil ; De-energized
3. Test results:
No abnormality was observed after 500 cycles.
1 cycle
1 hour
T1 T2
85°C 185°F
–40°C –40°F
T1 = 30 min.
T2 = 30 min.
Component housing pull
22 - 28 cm
8.661 - 11.024 inch
10
D-7
Compound stress test
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=3
2. Test conditions:
A) Mechanical vibration
(1) Frequency ; 10 to 500 Hz
(2) Acceleration ; 98 m/s2 (Average), 294 m/s2 (Peak)
(3) Coil ; De-energized
B) Thermal shock
(1) Low temperature ; –55°C –67°F
(2) High temperature ; 85°C 185°F
(3) Number of cycles ; 10 cycles
(4) Coil ; De-energized
Remark) Vibration is continuously applied during the thermal
shock test.
Samples are subjected the test under package
condition.
3. Test results:
No abnormality was observed after test.
D-5
Damp heat
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=11
2. Test conditions:
(1) Ambient Temperature ; 85°C 185°F
(2) Ambient Humidity ; 85 % RH
(3) Exposure period ; 1000 hours
3. Test results:
No abnormality was observed for all samples after 1000 hours.
D-6
Humidity cycle
1. Sample: AWAP01226 (12 , 1550nm , 4.5VDC coil) n=6
2. Test conditions:
(1) Number of cycles ; 100 cycles
(2) Coil ; De-energized
3. Test results:
No abnormality was observed after 100 cycles.
Humidity Uncontrolled
(h)
24
22.5
21
18
17.5
15.5
13.5
10
8
7.5
5.5
2
0
–10
25
65
90
95
1 cycle (24h)
Temperature (°C)
Humidity
(%)