3
Interconnect Solutions
http://www.3Mconnectors.com
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
3M™ Pleated Foil Shielded Cable
.025" 30 AWG Stranded, TPE Primary, Thin TPE Cover 90202 Series
• Can be used with IDC mass termination connectors
• Pleated copper foil provides exibility and 35db
average shielding effectiveness
• See Regulatory Information Appendix (RIA) for
chemical compliance information
(RIA E1 & C1 apply)
Date Modied: September 3, 2013 TS-0730-E
Sheet 1 of 2
Physical
Insulation Material: Thermoplastic Elastomer (TPE)
Color: Gray
Primary Material: Thermoplastic Elastomer (TPE)
Color: Gray
Marking Standard: None
Canadian Option: AWM 20297 105C 150V VW1 3M NU C AWM IA 105C 150V FT1 EU <50V
Conductors: 30 AWG, 7 × 38 AWG [ 7 × Ø 0.102 ] Tinned Stranded Copper
Shielding: Solid, Pleated, Copper Foil
Electrical
Voltage Rating: USA: 150V Canada: 150V EU: <50V
Insulation Resistance: (Primary) > 1 × 1010 Ω/10 ft. [ 3 m ]
Characteristic Impedance: Unbalanced Balanced
46.1 Ω 88.5 Ω
Capacitance: 35.3 pF/ft [ 116 pF/m ] 18.3 pF/ft [ 60 pF/m ]
Inductance: 0.08 μH/ft [ 0.25 μH/m ] 0.14 μH/ft [ 0.47 μH/m ]
Propagation Delay: 1.63 ns/ft [ 5.35 ns/m ] 1.62 ns/ft [ 5.31 ns/m ]
Velocity of Propagation: 62% 62%
Note: Unbalanced is measured between ground-signal-ground conductors with shield grounded. Balanced is measured between signal conductors within a pair with the shield floating.
Environmental
Temperature Rating: -20°C to +105°C
Flammability Rating: USA: VW-1 Canada: FT1
Regulatory Classication: EU: Not compliant, see RIA note E4
CN: , see RIA note C1
Regulatory Information Appendix (RIA) attached
UL File No.: E118773, Power Limited Circuit Cable: CL2