Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
AQ-A
ASCTB21E 201201-T1
RATING
1. Ratings (Measurement condition: at 20°C 68°F, Input ripple: 1% or less)
Note: * When the load current is less than the rated minimum load current, please refer to “Cautions for Use”.
2. Characteristics (Measurement condition: at 20°C 68°F, Input ripple: 1% or less)
REFERENCE DATA
1. Load current vs. ambient temperature
Use load current within range specified in the figure below.
Tested condition
Item Part No. AQA211VL AQA411VL AQA611VL Remarks
Input side
Input voltage 4 to 32V DC
Input current Max. 20mA
Drop-out voltage Min. 1V
Output side
Max. load current 15A 25A 40A
Load voltage 75 to 250V AC
Frequency 45 to 65Hz
Non-repetitive surge current 150A 250A 400A In one cycle at 60Hz
“OFF-state” leakage current Max. 10mA at 60Hz
“ON-state” voltage drop Max. 1.6V at Max. carrying current
Min. load current* 100mA
Item AQA211VL AQA411VL AQA611VL Remarks
Operate time Max. 1/2 cycle of voltage sine wave + 1ms
Release time Max. 1/2 cycle of voltage sine wave + 1ms
Insulation resistance Min. 100MΩ between input and output at 500 V DC
Breakdown voltage 4,000 Vrms between input and output
2,500 Vrms between input, output and case for 1min.
Vibration resistance (Functional) 10 to 55Hz double amplitude of 1.5mm X, Y, Z axes
Shock resistance (Functional) Min. 980 m/s2X, Y, Z axes
Ambient temperature –20°C to +80°C –4°F to +176°FNon-condensing at low temperatures
Storage temperature –20°C to +85°C –4°F to +185°FNon-condensing at low temperatures
Operational method Zero-cross (Turn ON and Turn OFF)
With external heat sink
1) (1) When using standard heat sink
(AQP-HS-J25A)
(2) When using standard heat sink
(AQP-HS-30/40A)
(3) When using standard heat sink
(AQP-HS-J10A)
(4) When using standard heat sink
(AQP-HS-SJ20A)
2) If attached to a heat sink, use a heat conductive
compound (Ex. Momentive Performance Materials
Inc. YG6111 or TSK5303) of similar coating to
improve cooling.
Without external heat sink
If the mounting surface is not metallic and a heat sink
is not used, expose the bottom surface and plate
surface to improve heat dissipation.
(1) 15A type (AQA211VL) (2) 25A type (AQA411VL)
5
10
15
20
00-20 20 40 60 80 100
Ambient temperature, °C
Load current, A
When using AQP-HS-J10A or
AQP-HS-SJ20A
When using as stand-alone
Ambient temperature, °C
Load current, A
When using as stand-alone
10
5
15
25
20
30
00-20 20 40 60 80 100
When using
AQP-HS-30/40A
When using
AQP-HS-J10A
When using
AQP-HS-SJ20A
(3) 40A type (AQA611VL) 2. Non-repetitive surge current vs. carrying
time characteristics
3. Input current vs. input voltage characteristics
Ambient temperature, °C
Load current, A
When using as stand-alone
10
20
40
30
50
00-20 20 40 60 80 100
When using
AQP-HS-30/40A
When using
AQP-HS-J10A
When using
AQP-HS-J25A
When using
AQP-HS-SJ20A
100
200
400
300
500
0110100
AQA211VL AQA411VL AQA611VL
No. of cycles at 60 Hz
Non-repetitive surge current, A
4
8
16
12
20
001015202530535
Input voltage, V
Input current, mA