PCB relays 20 A class Micro power relay K SMD Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Features - Smallest power relay with surface mounted technology - Minimal weight (0.14 oz. / 4 g) - Maximum continuous current 30 A - SMD-terminals designed for convection and infrared reflow Typical applications - Rear window and seat heating - Wiper and indicator control - Lamp load - Motor management Car Industry Truck Industry Other Industry 86_3d06 Design Conditions Sealed; sealed version: sealing in accordance with IEC 68; immersion cleanable: protection class IP67 to IEC 529 (EN 60 529) All parametric, environmental and endurance tests are performed according to EIA Standard RS-407-A at standard test conditions unless otherwise noted: 23 C ambient temperature, 20-50% RH, 29.5 1.0" Hg (998.9 33.9 hPa). Weight Approx. 0.14 oz. (4 g) Nominal voltage 10, 12 V other nominal voltages on request Terminals PCB/SMD terminals, for assembling in printed circuit boards 474 All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications. PCB relays 20 A class Micro power relay K SMD Dimensional drawing 12 0.1 5,8 0.2 0,6 0.2 0.1 0,7 7,65 0.1 3x*) 0.1 2,5 A 12,9 0.2 0.1 2x*) 0,95 0.2 0.2 1,8 11,3 0.2 0.1 0,4 At terminal tip *) Dimension without soldering 86esw_se View of the terminals (Bottom view) 3x 1,3 +0,05 0 8,5 3,06 1,5 3,06 1,56 C 0,65 6,01 B 3,36 5 4x 0,4 0,2 1,5 16 4 3 M A B M A M A B M A 1 4,09 0,4 0,3 2 1,5 4,06 0,4 0,2 M A C M A +0,05 0 2x0,8 7,5 4x 0,4 0,2 M A C M A 86esw_an Remark: Positional tolerances according to DIN EN ISO 5458 475 All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications. PCB relays 20 A class Micro power relay K SMD Contact data Contact configuration Changeover contact/ Form C AgNi0.15 (AgSnO2 available on request) Contact material Circuit symbol (see also Pin assignment) Make contact/ Form A AgSnO2 5 3 4 Max. switching current1) On Off Limiting continuous current Voltage drop at 10 A Mechanical endurance (without load) Electrical endurance at cyclic temperature -40 /+23 /+85 C and 13,5 VDC 1) 2) 3) + 40 A2) 30 A NC/NO 25 A/30 A 15 A/20 A at 23 C at 85 C The values apply to a resistive or inductive load with suitable spark suppression. This current may flow for a maximum of 3 sec for a make/break ratio of 1 : 10. Corresponds to the peak inrush current on initial actuation (cold filament). 86u_me Does not take into account the temperature rise due to the contact current E = pre-energization Pin assignment 4 4 5 5 2 1 changeover contact/ 1 form C 3 1 86ess_ab 2 40 A2)/100 A3) 30 A 30 A 20 A 30 A 20 A Lamp load: > 1 x 105 operations 100 A inrush /10 A steady state 4) With polarization + at terminal 4. Operating voltage range 1 make contact/ 1 form A 40 A2)/70 A3) 30 A Typ. 30 mV > 5 x 106 operations Wiper reserve: Motor reserve blocked: Flasher load: > 3 x 105 operations > 1 x 105 operations > 2 x 106 operations 25 A make /5 A break; 20 A up to 3 x 21 W , 4) generator peak - 10 A Turn and hazard signal L= 1.0 mH L= 0.77 mH in sequence Resistive load: > 3 x 105 operations 20 A on NO-contact Make contact/ Form A AgSnO2 1 86esw_ab 476 All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications. PCB relays 20 A class Micro power relay K SMD Coil data Available for nominal voltages Nominal power consumption of the unsuppressed coil at nominal voltage Test voltage winding/contact Upper limit temperature for the coil Maximum ambient temperature range1) Max. switching rate without contact loading Operate time2) Release time2) 10, 12 VDC (other coils on request) 0.64 W 500 VACrms 155 C - 40 to + 105 C 50 Hz Typ. 3 msec Typ. 1.5 msec See also operating voltage range diagram Measured at nominal voltage without coil suppression unit N.B. A low resistive device in parallel to the relay coil slows down the armature movement and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding. 1) 2) Recommended reflow soldering profile max. 60 s 240 Recommended soldering range 205 2 K/s 180 170 Preheating range 140 120 4 K/s min. 30 s 4 K/s min. 120 s RT max. 5 min 30 s Peak temperature range: 205 to 240 C Time for temperature > 183 C: 30 to 60 s 86sprof Mechanical data Enclosure Sealed Sealed relay is suitable for immersion cleaning of PCB assembly or conformal coating. 477 All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications. PCB relays 20 A class Micro power relay K SMD Operating conditions Temperature range, storage Test Cold storage Dry heat Climatic cycling with condensation Thermal change Thermal shock Damp heat cyclic constant Corrosive gas Vibration resistance Relevant standard IEC 68-2-1 IEC 68-2-2 EN ISO 6988 IEC 68-2-14 IEC 68-2-14 Testing as per Ba Nb Na -40 C to 155 C Dimension 72 h 1000 h 20 cycles 35 cycles 100 cycles IEC 68-2-30 Db, Variant 2 IEC 68-2-3 Ca IEC 68-2-42 - IEC 68-2-43 IEC 68-2-6 (sine pulse form) Shock resistance 6 cycles 56 days 10 days 10 days 10 ... 500 Hz IEC 68-2-27 (half-sine pulse form) 6 msec Comments -40 C 85 C Storage 8/16 h - 40/+ 105 C - 40/+ 105 C Dwell time 1 h 40 C / 55 C / 93% 40 C / 93% No change in the switching state > 10 sec, 6 g No change in the switching state > 10 sec up to 30 g 215 C; 3 sec wetting 260 C 10 sec (see soldering profile) 1 min / 70 C Solderability IEC 68-2-58 Resistance to soldering heat IEC 68-2-58 Sealing IEC 68-2-17 Qc, Method 2 Contact arrangement Contact material Enclosure Terminals Form C Form C Form A; lamp load Form A; flasher load AgNi0.15 AgSnO2 AgSnO2 AgSnO2 Sealed Sealed Sealed Sealed Printed circuit/SMD Printed circuit/SMD Printed circuit/SMD Printed circuit/SMD Allowable overdrive (VDC) at 23 C1) at 105 C1) Ordering information Part number (Replace * with "Coil designator") Micro power relay K SMD V23086-M1*-A303 V23086-M1*-A403 V23086-M1031-A502 V23086-M1*-A602 Coil versions 1) Coil designator Micro power relay K SMD Rated coil voltage (V) Coil resistance +/- 10% () Must operate voltage (VDC) Must release voltage (VDC) 011 012 031 12 10 12 225 156 156 6.9 5.7 6.9 1.5 1.25 1.5 Allowable overdrive is stated with no load current flowing through the relay contacts and minimum coil resistance. Standard delivery packs (orders in multiples of delivery pack) Micro power relay K SMD: 1000 pieces 478 All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications. 24 20 20 15 13 13