LPS200-M Series Data Sheet
Environmental Specications
Operating temperature 0 °C to 50 °C ambient derate each output as 2.5% per degree from 50° to 70 °C. -20 °C start up
Storage temperature -40 °C to +85 °C
Electromagnetic susceptibility Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Humidity Operating; non-condensing 10% to 95% RH
Vibration IEC68-2-6 to the levels of IEC721-3-2
MTBF calculated 1 million hours at full load and 25 °C ambient conditions. 230 Vac input, Bellcore
Pin Assignments
Connector LPS200-M
SK1 Pin 1 Neutral
Pin 3 Line
SK2 TB-1 Common
TB-2 Main output
SK3 Pin 1 +V1 Remote sense
Pin 2 -V1 Remote sense
Pin 3 N/C
Pin 4 N/C
Pin 5 +Power fail
Pin 6 Common
Pin 7 N/C
Pin 8 Common
Pin 9 +12 V Fan
Pin 10 +12 Fan Return (isolated)
Mating Connectors
AC Input
(SK1)
Molex 09-50-8031 (connector)
PINS: 08-52-0072
AC Ground Molex 01-90020001
DC Output (SK2) Molex 19141-0058/0063 or 19099-0044/0048
Spade lug based on Cable Ampacity/AWG
Control Sense
(SK3)
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
Artesyn Embedded Technologies Connector Kit #70-841-020,
includes all of the above.
1. Specications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ± 0.02” (± 0.5 mm)
3. Mounting holes MH1 and MH2 should be grounded for EMI purposes.
4. Mounting hole MH1 is safety ground connection.
5. Specications are for convection rating at factory settings at 115 VAC input, 25 °C
unless otherwise stated.
6. This power supply requires mounting on metal standoffs 0.20” (5m) in height.
7. Warranty: 2 years
8. Weight: 0.75 lb/0.34 kg
Ordering Information
Model Number Output Voltage Minimum
Load
Maximum Load with
Convection Cooling
Maximum Load with
30CFM Forced Air
Peak Load Regulation2Ripple
P/P (PARD)3
LPS202-M 5 V 0 A 20 A 40 A 44 A ± 2% 50 mV
LPS203-M 12 V 0 A 10.3 A 20.8 A 22 A ± 2% 120 mV
LPS204-M 15 V 0 A 8.3 A 16.6 A 18 A ± 2% 150 mV
LPS205-M 24 V 0 A 5.2 A 10.4 A 11.5 A ± 2% 240 mV
LPS208-M 48 V 0 A 2.6 A 5.2 A 5.8 A ± 2% 480 mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2 . At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3 . Peak-to-peak with 20 mHz bandwidth and 10 µF (tantalum capacitor) in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4.
This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC
compliance to appropriate standards must be veried at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is
not intended for sale to End Users.