http://www.tracopower.com Page 2 of 3
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Input Specifications
Input current no load / full load 5 Vin models 40 mA / 800 mA typ.
12 Vin models 20 mA / 300 mA typ.
24 Vin models 5 mA / 150 mA typ.
48 Vin models 3 mA / 75 mA typ.
Start-up voltage / 5 Vin models 4 VDC / 3.5 VDC typ.
under voltage shut down 12 Vin models 7 VDC / 6.5 VDC typ.
24 Vin models 12 VDC / 11 VDC typ.
48 Vin models 24 VDC / 22 VDC typ
Surge voltage (1 sec. max.) 5 Vin models 11 V max.
12 Vin models 25 V max.
24 Vin models 50 V max.
48 Vin models 100 V max.
Reverse voltage protection 1.0 A max.
Conducted noise (input) (5 V input models excluded) EN 55022 level A, FCC part 15, level A
Output Specifications
Voltage set accuracy ±1 %
Regulation – Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 10 – 100 %
single output models 0.5 % max.
dual output models balanced load 1.0 % max.
dual output models unbalanced load 2.0 % max.
Ripple and noise (20 MHz Bandwidth) 60 mVpk-pk max
Transiente response – Recovery time 500 μs max.
(25% load step change) – Deviation 5 % max.
Temperature coefficient ±0.02 %/K
Current limitation >110 % of Iout max., constant current
Short circuit protection indefinite, automatic recovery
Capacitive load single output models 4000 μF max.
dual output models 1000 μF max. (each output)
General Specifications
Temperature ranges – Operating –40°C to +85°C
– Case temperature +100°C max.
– Storage –55°C to +125°C
Derating 3 %/K above 70°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTBF (MIL-HDBK-217 F, at +25°C, ground benign) >1.1 Mio. h
Isolation voltage (60 sec.) – Input/Output 1’500 VDC
Isolation capacitance – Input/Output 65 pF typ
Isolation resistance – Input/Output (500 VDC) >1‘000 M Ohm
Switching frequency 300 kHz typ. (Pulse frequency modulation PFM)
Safety standards cUL/UL 60950-1, IEC/EN 60950-1
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS directive 2011/65/EU
DC/DC Converters