© 2013 Kavlico. All rights reserved.
Warning: The product information contained in this catalogue is given purely as information and does not constitute a representation, warranty or any form of contractual commitment. Kavlico reserve the right to
modify their products without notice. It is imperative that we should be consulted over any particular use or application of our products and it is the responsibility of the buyer to establish, particularly through all the
appropriate tests, that the product is suitable for the use or application. Under no circumstances will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion,
use in conjunction with other electrical or electronic components, circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
Before installation and operation, ensure that the appropriate pressure sensor has
been selected in terms of pressure range, design and specific measuring conditions.
Non-compliance can result in serious injury and/or damage to the equipment.
P500 -100 - A - E - 1 - A
Example: P500 - 100 - A - E - 1 - A
Description: P500 Sensor, 0 - 100 PSI Absolute, Fluorosilicone Seal Material,
1/4 - 18 NPT Pressure Connection, with Mating Connector
1B 0 – 1 Bar
1.6B 0 – 1.6 Bar
2.5B 0 – 2.5 Bar
4B 0 – 4 Bar
6B 0 – 6 Bar
10B 0 – 10 Bar
16B 0 – 16 Bar
25B 0 – 25 Bar
40B 0 – 40 Bar
50B 0 – 50 Bar
70B 0 – 70 BarA Only
XXB 0 – XX Bar
(Large Volume Only)
Use this diagram, working top to bottom and left to right to
construct your model number. An example is shown below. Custom
OEM options are also available.
P500 Next Generation Ceramic Pressure Sensor
Pressure Ranges
Reference
Seal Material
Pressure Connection
Electrical Connection*
15
20
30
50
75
100
150
200
300
500
750
1000
XXX
A
S
A
C
D
E
F
1
4
5
6
9
10
0 - 15 PSI
0 - 20 PSI
0 - 30 PSI
0 - 50 PSI
0 - 75 PSI
0 - 100 PSI
0 - 150 PSI
0 - 200 PSI
0 - 300 PSI
0 - 500 PSI
0 - 750 PSI
0 - 1000 PSIA Only
0 - XXX PSI
(Large Volume Only)
Absolute
Sealed Gage (Referenced to 14.7 PSIA)
Fluorocarbon / Viton (-25° to +125°C)
Fluorosilicone (-40° to +125°C)
Ethylene Propylene (-40° to 120°C)
1/4 - 18 NPT
(External Threads)
1/8 - 27 NPT
(External Threads)
Stud End DIN 3852-B-G 1/4
(External Threads)
Tapped Hole DIN 3852-Y-G 1/4
(Internal Threads)
3/8 - 24 UNF-2A Per SAE J1926/2
(External Threads)
3/8 - 24 UNF-2B Per SAE J1926/2
(Internal Threads)
With Mating Connector, w/12”, 18 AWG Leads
Without Mating Connector
Technical Specifications
Note: Performance Specifications with 5 Vdc ± 0.002 Vdc supply at 25°C
1) Total Error Band includes all sources of error, including effects of Offset, Span, Temperature
and Accuracy
2) Electrical termination (black) for pressure ranges ≤ 350 PSI [24 Bar], (white) for pressure
ranges > 350 PSI [24 Bar]
Pressure Ranges:
Proof Pressure:
Burst Pressure:
Supply Voltage:
Supply Current:
Nominal Output Voltage:
Linearity Error:
Total Error Band1:
Output Impedance:
Over Voltage Protection:
Reverse Polarity Protection:
Operating Temperature:
Storage Temperature:
Service Life:
Vibration:
Mechanical Shock:
Ingress Protection:
Stability:
Response Time:
Housing Material:
Weight:
Electrical Termination:
Pressure Connection:
Output Load:
See “How to Order”
3x F.S. Pressure (up to 200 PSI [14 Bar])
2x F.S. Pressure (above 200 PSI [14 Bar])
1,500 PSI [100 Bar] (up to 350 PSI [24 Bar])
2,500 PSI [170 Bar] (above 350 PSI [24 Bar])
5.0 ± 0.5 Vdc
<5 mA
0.5 to 4.5 Vdc
< ±0.5% of Span
±1.5% of Span (0°C ≤ T ≤ 85°C)
±2.0% of Span (T < 0°C, T > 85°C)
<100 Ω
36 Vdc
-36 Vdc
-40°C to +125°C (Seal Material Dependent)
-40°C to +125°C (Seal Material Dependent)
10 Million Full Pressure Cycles (Minimum)
10 g’s Peak-to-Peak Sine (10 to 2,000 Hz)
75 g’s, 1/2 Sine Wave
IP67
±0.5% of Full Span over 1-Year
< 2ms to 63% of Final Output Voltage
with step change in Input Pressure
Brass (P ≤ 350 PSIA [24 BarA])
304 Stainless Steel (P > 350 PSIA [24 BarA])
< 50 grams
Packard Electric Metri-Pack 150 Series2
See “How to Order”
> 10 kΩ
How to Order
Don’t see what you want?
Call us at +1 (619) 710-2068 to customize this product
to meet your application-specific needs!
Potsdamer Str. 14, 32423 Minden, Germany
Tel: +49 571 3859-0 - Fax: +49 571 3859-119
Email: info@kavlico.de
www.kavlico.com
235 E. Main St., Suite 102A, Northville, MI 48167, USA
Tel: +1 (248) 465-0815 - Fax: +1 (248) 465-0810
Email: pressure.sensors@kavlico.com