HM51-3R9KLF 3.9 .007 8.40 15.5
HM51-4R7KLF 4.7 .008 7.90 13.9
HM51-5R6KLF 5.6 .011 6.70 12.6
HM51-6R8KLF 6.8 .011 6.70 11.6
HM51-8R2KLF 8.2 .013 6.20 9.89
HM51-100KLF 10 .017 5.40 8.70
HM51-120KLF 12 .019 5.10 8.21
HM51-150KLF 15 .022 4.70 7.34
HM51-180KLF 18 .023 4.70 6.64
HM51-220KLF 22 .026 4.40 6.07
HM51-270KLF 27 .027 4.30 5.36
HM51-330KLF 33 .032 4.00 4.82
HM51-390KLF 39 .033 3.90 4.36
HM51-470KLF 47 .035 3.80 3.98
HM51-560KLF 56 .037 3.70 3.66
HM51-680KLF 68 .047 3.30 3.31
HM51-820KLF 82 .060 2.90 3.10
HM51-101KLF 100 .090 2.30 2.79
HM51-121KLF 120 .113 2.10 2.54
HM51-151KLF 150 .129 2.00 2.22
HM51-181KLF 180 .150 1.80 1.98
HM51-221KLF 220 .162 1.76 1.89
HM51-271KLF 270 .208 1.55 1.63
HM51-331KLF 330 .212 1.53 1.51
HM51-391KLF 390 .281 1.33 1.39
HM51-471KLF 470 .380 1.15 1.24
HM51-561KLF 560 .420 1.10 1.17
HM51-681KLF 680 .548 0.96 1.05
HM51-821KLF 820 .655 0.87 0.97
HM51-102KLF 1,000 .844 0.77 0.87
HM51-122KLF 1,200 1.04 0.70 0.79
HM51-152KLF 1,500 1.18 0.65 0.70
HM51-182KLF 1,800 1.56 0.57 0.64
HM51-222KLF 2,200 2.00 0.50 0.58
HM51-272KLF 2,700 2.06 0.50 0.53
HM51-332KLF 3,300 2.63 0.44 0.47
HM51-392KLF 3,900 2.75 0.43 0.43
HM51-472KLF 4,700 3.19 0.40 0.39
HM51-562KLF 5,600 3.92 0.36 0.359
HM51-682KLF 6,800 5.69 0.30 0.322
HM51-822KLF 8,200 6.32 0.28 0.293
HM51-103KLF 10,000 7.30 0.26 0.266
Outline Dimensions (Inch / mm)
Notes: (1) Inductance is measured at 1kHz without DC current.
(2) The rated DC current is based on an approximate 20°C temperature rise.
(3) The incremental current (INCR I) is the approximate current at which the inductance will be decreased by 5% from its initial (zero DC) value
due to saturation.
Specifications @ 25°C
Inductance DC Rated INCR
Part Nominal (1) Resistance IDC (2) IDC (3)
Number µH ± 10% W Max. Amps Amps
Inductance DC Rated INCR
Part Nominal (1) Resistance IDC (2) IDC (3)
Number µH ± 10% W Max. Amps Amps
Max.
• Inductance Range 3.9µH to 10,000µH
• StandardTolerance ±10%
• OperatingTemperatureRange -55C to +105°C
Axially Leaded Miniature Power Inductors
Electrical / Environmental
Inductance Code:
First2digitsaresignicant.Lastdigitdenotes
the number of trailing zeros. For values below
10µH, “R” denotes the decimal point.
Inductance Tolerance:
J = ±5%
K = ±10%
M = ±20%
Model Series
HM51 - 330 K LF
LeadFree
Packaging
Capacity = 800 Units
Standard: Boxes
Ordering Information
HM51
RoHS
Compliant