Model No. SF-C11 (Note 2) SF-C12 SF-C13 (Note 2)
Item
Connectable safety light curtains
SF4B / SF4B-G / SF4D / SF2B series SF4B / SF4B-G series
Safety light curtains manufactured by Panasonic Industrial Devices SUNX
Applicable standards IEC 61496‑1, EN 61496‑1, ANSI/UL 61496‑1, CAN/CSA 61496‑1, JIS B 9704‑1, etc.
CE marking directive compliance
Machinery Directive, Low Voltage (SF-C11/C13 only) Directive, EMC Directive, RoHS Directive
Control category ISO 13849‑1 (EN ISO 13849‑1, JIS B 9705‑1) compliance up to Category 4, PLe standards
Supply voltage / Current consumption
24 V DC ±10 % Ripple P‑P 10 % or less / 100 mA or less (without safety light curtain)
Fuse (rating) Built‑in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Safety output NO contact × 3 (13‑14, 23‑24, 33‑34) NO contact × 2 (13‑14, 23‑24) NO contact × 3 (13‑14, 23‑24, 33‑34)
Utilization category AC‑15, DC‑13 (IEC 60947‑5‑1)
Rated operation voltage (Ue) /
Rated operation current (le)
30 V DC / 6 A, 230 V AC / 6 A, resistive load
(For inductive load, during contact protection)
Min. applicable load: 10 mA (at 24 V DC) (Note 3)
24 V DC / 1 A, resistive load
(For inductive load, during contact protection)
Min. applicable load: 15 mA (at 24 V DC)
30 V DC / 4 A, 230 V AC / 4 A, resistive load
(For inductive load, during contact protection)
Min. applicable load: 10 mA (at 24 V DC) (Note 3)
Contact resistance 100 mΩ or less (initial value) 50 mΩ or less (initial value) 100 mΩ or less (initial value)
Contact protection fuse rating
6 A (slow blow) 3 A (slow blow) 4 A (slow blow)
Pick‑up delay (Auto reset/Manual reset)
80 ms or less / 90 ms or less 30 ms or less / 30 ms or less 80 ms or less / 90 ms or less
Response time 10 ms or less 14 ms or less 10 ms or less
Auxiliary output
Safety relay contact (NC contact) ×1 (41‑42) (Related to safety output) Safety relay contact (NC contact) × 1 (31‑32) (Related to safety output) Safety relay contact (NC contact) × 1 (41‑42) (Related to safety output)
Rated operation voltage/current
24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC) 30 V DC / 3 A, Min. applicable load: 15 mA (at 24 V DC) 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC)
Contact protection fuse rating
2 A (slow blow) 3 A (slow blow) 2 A (slow blow)
Semiconductor auxiliary output
(AUX)
<Minus ground (Setting for PNP)>
PNP open‑collector transistor
<Plus ground (Setting for NPN)>
NPN open‑collector transistor
–
PNP open‑collector transistor
Output operation
Related to auxiliary output of safety light curtain
–
ON when the safety light curtain is interrupted
Excess voltage category II III II
Polarity selection function
(Note 4)
Incorporated (Sliding switch allows selection of plus/minus ground)
Minus ground: Correspond to PNP output safety light curtain
Plus ground: Correspond to NPN output safety light curtain
Incorporated (Cable connection allows selection of plus/minus ground)
Minus ground: Correspond to PNP output safety light curtain
Plus ground: Correspond to NPN output safety light curtain
Pollution degree 2
Protection Enclosure: IP40, Terminal: IP20 IP65 Enclosure: IP40, Terminal: IP20
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
Enclosure material ABS Die‑cast aluminum ABS
Weight Net weight: 320 g approx. Net weight: 1 kg approx. Net weight: 200 g approx.
Notes: 1)
Where measurement conditions have not been specied precisely, the
conditions used were an ambient temperature of +20 °C +68 °F.
2) SF-C11 and SF-C13 have acqusred the Korea S‑mark.
3) If several SF-C11 or SF-C13 units are being used in a line together, leave
a space of 5 mm 0.197 in or more between each unit. If the units are
touching each other, reduce the rated operating current for safety output
in accordance with the ambient operating temperature as shown in the
graphs at right.
4) Please switch the sliding switch to the PNP side for minus ground and to
the NPN side for plus ground.
5)
Refer to p.667 for details of the specications for the control unit SF-C11/C12/C13.
Ambient temperature (°C °F)
0
32
1
2
3
4
5
35
95
40
104
45
113
50
122
55
131
Rated operation current (A)
1
2
3
4
5
6
Ambient temperature (°C °F)
0
32
35
95
40
104
45
113
50
122
55
131
Rated operation current (A)
Dilating when SF-C11 units
are mounted close together
Dilating when SF-C13 units
are mounted close together
Model No. SF-C14EX(-01) (Note 2)
Item
Connectable safety light curtains
SF4B / SF4B-G series
Applicable standards IEC 61496‑1, EN 61496‑1, ANSI/UL 61496‑1, CAN/CSA 61496‑1, JIS B 9704‑1, etc.
CE marking directive compliance
Machinery Directive, EMC Directive, RoHS Directive
Control category ISO 13849‑1 (EN ISO 13849‑1, JIS B 9705‑1) compliance up to Category 4, PLe standards
Supply voltage / Current consumption
24 V DC ±10 % Ripple P-P 10 % or less / 0.2 A or less (without safety light curtain and other external connecting device)
Safety output (Safety output 1, 2, 3)
PNP open‑collector transistor 2 outputs × 3 or NPN open‑collector transistor 2 outputs × 3 (selectable using a slider switch)
Operation mode
(Output operation)
Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)
Safety output 2:
ON when the safety light curtain is in light receiving condition or the muting function is valid
OFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)
Safety output 3:
ON when the emergency stop is invalid, OFF when the emergency stop is valid
Response time OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the safety light curtain)
ON response: 90 ms or less (auto‑reset) / 140 ms or less (manual reset) (Note 4)
Auxiliary outputs
[Auxiliary output 1, 2, 3, 4 (Note
5)]
PNP open‑collector transistor × 3 or NPN open‑collector transistor × 3 (selectable using a slider switch)
Operation mode
(Output operation)
Auxiliary output 1:
ON when the muting function is invalid, OFF when the muting function is valid
Auxiliary output 2:
ON when the override function is invalid, OFF when the override function is valid
Auxiliary output 3:
ON when the muting lamp is normal, OFF when the muting lamp is error
Auxiliary output 4: ON when the safety light curtain is in light interrupted condition, OFF when the safety light curtain is in light receiving condition (Note 5)
Muting lamp output Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit)
Protection Enclosure: IP40, Terminal: IP20
Ambient temperature –10 to +55 °C +14 to +131 °F (No dew condensation or icing allowed), Storage: –25 to +70 °C –13 to +158 °F
Material Enclosure: ABS
Connection terminal Detachable spring‑cage terminal
Weight Net weight: 250 g approx.
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) SF-C14EX-01 is Handy‑controller SFB-HC (optional) non‑compatible type.
3)
Both safety output 1 and 2 are OFF when the emergency stop is valid regardless of whether the safety light curtain is in the light receiving or light interrupted condition.
4) The auto‑reset cannot be used with safety output 3.
5) The auxiliary output incorporated in the SF4B / SF4B-G series is outputed.
6) Refer to p.668 for details of the specications for the control unit SF-C14EX(-01).
Control units
SPECIFICATIONS
523
Safety Light Curtain Type 4 SF4B SERIES Ver.2 SF4B-G SERIES Ver.2
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Safety Light
Curtains
Safety
Control Units
Safety
Components
SF4D
SF4B/
SF4B-G
SF4B-C
SF4C
BSF4-AH80
SF2B
SF2C
Denition of
Sensing Heights