Industrial miniature circuit breakers UL 489 DIN rail miniature circuit breakers Optimum product quality, tested reliability and safety stand for the best protection of personnel, installations and plant. Eaton's FAZ-NA DIN rail mountable circuit breakers are designed for use in branch service applications. Features * Complete range of ULT 489 Listed DIN rail mounted miniature circuit breakers, up to 40A current rating * Rated for 10 kAIC at 277/480 Vac * Current limiting design provides fast short-circuit interruption, reducing the let-through energy that can damage the circuit * Suitable for branch circuit device protection * Thermal-magnetic overcurrent protection * * Three levels of short-circuit protection, categorized by B, C and D curves Trip-free design--breaker can not be defeated by holding the handle in the ON position * Captive screws cannot be lost * SWD (switching duty)-- suitable for switching fluorescent lighting loads (I n 20A) * Fulfill UL 489, CSAT C22.2 No. 5 and also IEC 60947-2 Standard * For use in applications for which UL 1077 or CSA C22.2 No. 235 are also allowed * Field-installable shunt trip and auxiliary switch subsequent mounting * Separate version for ring tongue connection (Type FAZ-RT); terminal screws can be removed (on both sides) * Module width of only 17.7 mm (per pole) * Contact position indicator (red/green) * Easy installation on DIN rail * Possibility for sealing the toggle in ON or OFF position * Complements UL 1077 offering FAZ-NA UL 489 miniature circuit breakers catalog numbering system FAZ - C 6 / 1 - NA - SP Breaker Family FAZ = FAZ UL circuit breaker Single Packaging Trip Characteristic B = 3-5X In A C = 5-10X In A D = 10-20X In A Ampere Rating 0.5 = 0.5A 1 = 1A 1.5 = 1.5A 2 = 2A 3 = 3A 4 = 4A 5 = 5A 6 = 6A 7 = 7A 8 = 8A 10 = 10A 13 = 13A 15 = 15A 16 = 16A 20 = 20A 25 = 25A 30 = 30A 32 = 32A 35 = 35A 40 = 40A Number of Poles 1 = Single-pole 2 = Two-pole 3 = Three-pole Terminal NA = RT = DC = UL 489 branch circuit with screw terminals UL 489 branch circuit with ring tongue terminals UL 489 branch circuit at 125 Vdc per pole SP = Blank = Single packaging for C and D curve, single-pole only Standard packaging A I = Rated current for instantaneous trip characteristics. n FAZ-NA UL 489 circuit breakers--10 kAIC Single-Pole A Amperes Catalog Number B Curve (3-5X In Current Rating) 1 FAZ-B1/1-NA 1.5 FAZ-B1.5/1-NA 2 FAZ-B2/1-NA 3 FAZ-B3/1-NA 4 FAZ-B4/1-NA 5 FAZ-B5/1-NA 6 FAZ-B6/1-NA 7 FAZ-B7/1-NA 8 FAZ-B8/1-NA 10 FAZ-B10/1-NA 13 FAZ-B13/1-NA 15 FAZ-B15/1-NA 16 FAZ-B16/1-NA 20 FAZ-B20/1-NA 25 FAZ-B25/1-NA 30 FAZ-B30/1-NA 32 FAZ-B32/1-NA 35 C FAZ-B35/1-NA 40 C FAZ-B40/1-NA Single-Pole A2 Amperes Catalog Number Single-Pole A2 Two-Pole A Three-Pole A Catalog Number Catalog Number Amperes Catalog Number FAZ-B1/2-NA FAZ-B1.5/2-NA FAZ-B2/2-NA FAZ-B3/2-NA FAZ-B4/2-NA FAZ-B5/2-NA FAZ-B6/2-NA FAZ-B7/2-NA FAZ-B8/2-NA FAZ-B10/2-NA FAZ-B13/2-NA FAZ-B15/2-NA FAZ-B16/2-NA FAZ-B20/2-NA FAZ-B25/2-NA FAZ-B30/2-NA FAZ-B32/2-NA FAZ-B35/2-NA FAZ-B40/2-NA FAZ-B1/3-NA FAZ-B1.5/3-NA FAZ-B2/3-NA FAZ-B3/3-NA FAZ-B4/3-NA FAZ-B5/3-NA FAZ-B6/3-NA FAZ-B7/3-NA FAZ-B8/3-NA FAZ-B10/3-NA FAZ-B13/3-NA FAZ-B15/3-NA FAZ-B16/3-NA FAZ-B20/3-NA FAZ-B25/3-NA FAZ-B30/3-NA FAZ-B32/3-NA FAZ-B35/3-NA FAZ-B40/3-NA D Curve (10-20X In Current Rating) 0.5 FAZ-D0.5/1-NA-SP FAZ-D0.5/2-NA 1 FAZ-D1/1-NA-SP FAZ-D1/2-NA 1.5 FAZ-D1.5/1-NA-SP FAZ-D1.5/2-NA 2 FAZ-D2/1-NA-SP FAZ-D2/2-NA 3 FAZ-D3/1-NA-SP FAZ-D3/2-NA 4 FAZ-D4/1-NA-SP FAZ-D4/2-NA 5 FAZ-D5/1-NA-SP FAZ-D5/2-NA 6 FAZ-D6/1-NA-SP FAZ-D6/2-NA 7 FAZ-D7/1-NA-SP FAZ-D7/2-NA 8 FAZ-D8/1-NA-SP FAZ-D8/2-NA 10 FAZ-D10/1-NA-SP FAZ-D10/2-NA 13 FAZ-D13/1-NA-SP FAZ-D13/2-NA 15 FAZ-D15/1-NA-SP FAZ-D15/2-NA 16 FAZ-D16/1-NA-SP FAZ-D16/2-NA 20 FAZ-D20/1-NA-SP FAZ-D20/2-NA FAZ-D25/1-NA-SP FAZ-D25/2-NA 25 FAZ-D30/1-NA-SP FAZ-D30/2-NA 30 FAZ-D32/1-NA-SP FAZ-D32/2-NA 32 FAZ-D35/1-NA-SP FAZ-D35/2-NA 35 C 40 C FAZ-D40/1-NA-SP FAZ-D40/2-NA Two-Pole A Three-Pole A Catalog Number Catalog Number C Curve (5-10X In Current Rating) 0.5 FAZ-C0.5/1-NA-SP FAZ-C0.5/2-NA 1 FAZ-C1/1-NA-SP FAZ-C1/2-NA 1.5 FAZ-C1.5/1-NA-SP FAZ-C1.5/2-NA 2 FAZ-C2/1-NA-SP FAZ-C2/2-NA 3 FAZ-C3/1-NA-SP FAZ-C3/2-NA 4 FAZ-C4/1-NA-SP FAZ-C4/2-NA 5 FAZ-C5/1-NA-SP FAZ-C5/2-NA 6 FAZ-C6/1-NA-SP FAZ-C6/2-NA 7 FAZ-C7/1-NA-SP FAZ-C7/2-NA 8 FAZ-C8/1-NA-SP FAZ-C8/2-NA 10 FAZ-C10/1-NA-SP FAZ-C10/2-NA 13 FAZ-C13/1-NA-SP FAZ-C13/2-NA 15 FAZ-C15/1-NA-SP FAZ-C15/2-NA 16 FAZ-C16/1-NA-SP FAZ-C16/2-NA 20 FAZ-C20/1-NA-SP FAZ-C20/2-NA FAZ-C25/1-NA-SP FAZ-C25/2-NA 25 FAZ-C30/1-NA-SP FAZ-C30/2-NA 30 FAZ-C32/1-NA-SP FAZ-C32/2-NA 32 C FAZ-C35/1-NA-SP FAZ-C35/2-NA 35 C 40 FAZ-C40/1-NA-SP FAZ-C40/2-NA Three-Pole A Catalog Number Catalog Number FAZ-D0.5/3-NA FAZ-D1/3-NA FAZ-D1.5/3-NA FAZ-D2/3-NA FAZ-D3/3-NA FAZ-D4/3-NA FAZ-D5/3-NA FAZ-D6/3-NA FAZ-D7/3-NA FAZ-D8/3-NA FAZ-D10/3-NA FAZ-D13/3-NA FAZ-D15/3-NA FAZ-D16/3-NA FAZ-D20/3-NA FAZ-D25/3-NA FAZ-D30/3-NA FAZ-D32/3-NA FAZ-D35/3-NA FAZ-D40/3-NA A For ring tongue terminals, remove suffix NA and add suffix RT. B For single packaging on single-pole C and D curves only, add suffix SP when ordering. C 240 Vac only. FAZ-C0.5/3-NA FAZ-C1/3-NA FAZ-C1.5/3-NA FAZ-C2/3-NA FAZ-C3/3-NA FAZ-C4/3-NA FAZ-C5/3-NA FAZ-C6/3-NA FAZ-C7/3-NA FAZ-C8/3-NA FAZ-C10/3-NA FAZ-C13/3-NA FAZ-C15/3-NA FAZ-C16/3-NA FAZ-C20/3-NA FAZ-C25/3-NA FAZ-C30/3-NA FAZ-C32/3-NA FAZ-C35/3-NA FAZ-C40/3-NA Eaton Corporation Electrical Sector 1111 Superior Avenue Cleveland, OH 44114 USA Eaton.com (c) 2013 Eaton Corporation All Rights Reserved Printed in USA Publication No. PA01101003E / Z12781 January 2013 Two-Pole A Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners.