UL 489 DIN rail miniature circuit breakers
Features
• CompleterangeofULT489
ListedDINrailmounted
miniaturecircuitbreakers,
upto40Acurrentrating
• Ratedfor10kAICat
277/480Vac
• Currentlimitingdesign
providesfastshort-circuit
interruption,reducingthe
let-throughenergythat
candamagethecircuit
• Suitableforbranchcircuit
deviceprotection
• Thermal-magneticovercurrent
protection
• Threelevelsofshort-circuit
protection,categorizedby
B,CandDcurves
• Trip-freedesign—breaker
cannotbedefeatedby
holdingthehandleinthe
ONposition
• Captivescrewscannotbelost
• SWD(switchingduty)—
suitableforswitching
fluorescentlightingloads
(In≤20A)
• FulfillUL489,CSATC22.2
No.5andalsoIEC60947-2
Standard
• Foruseinapplicationsfor
whichUL1077orCSAC22.2
No.235arealsoallowed
• Field-installableshunttrip
andauxiliaryswitch
subsequentmounting
• Separateversionfor
ringtongueconnection
(TypeFAZ-RT);terminal
screwscanberemoved
(onbothsides)
• Modulewidthofonly
17.7mm(perpole)
• Contactpositionindicator
(red/green)
• EasyinstallationonDINrail
• Possibilityforsealing
thetoggleinONor
OFFposition
• ComplementsUL1077offering
Optimum product quality, tested reliability and
safety stand for the best protection of personnel,
installations and plant. Eaton’s FAZ-NA DIN rail
mountable circuit breakers are designed for use
in branch service applications.
Industrial miniature
circuit breakers
Eatonisaregisteredtrademark
ofEatonCorporation.
Allothertrademarksareproperty
oftheirrespectiveowners.
Eaton Corporation
ElectricalSector
1111SuperiorAvenue
Cleveland,OH44114USA
Eaton.com
©2013EatonCorporation
AllRightsReserved
PrintedinUSA
PublicationNo.PA01101003E/Z12781
January2013
FAZ - C 6 / 1 - NA - SP
FAZ-NA UL 489 miniature circuit breakers catalog numbering system
FAZ-NA UL 489 circuit breakers—10 kAIC
Amperes
Single-Pole ATwo-Pole AThree-Pole A
Catalog Number Catalog Number Catalog Number
B Curve (3–5X In Current Rating)
1
1.5
2
3
FAZ-B1/1-NA
FAZ-B1.5/1-NA
FAZ-B2/1-NA
FAZ-B3/1-NA
FAZ-B1/2-NA
FAZ-B1.5/2-NA
FAZ-B2/2-NA
FAZ-B3/2-NA
FAZ-B1/3-NA
FAZ-B1.5/3-NA
FAZ-B2/3-NA
FAZ-B3/3-NA
4
5
6
7
8
FAZ-B4/1-NA
FAZ-B5/1-NA
FAZ-B6/1-NA
FAZ-B7/1-NA
FAZ-B8/1-NA
FAZ-B4/2-NA
FAZ-B5/2-NA
FAZ-B6/2-NA
FAZ-B7/2-NA
FAZ-B8/2-NA
FAZ-B4/3-NA
FAZ-B5/3-NA
FAZ-B6/3-NA
FAZ-B7/3-NA
FAZ-B8/3-NA
10
13
15
16
20
FAZ-B10/1-NA
FAZ-B13/1-NA
FAZ-B15/1-NA
FAZ-B16/1-NA
FAZ-B20/1-NA
FAZ-B10/2-NA
FAZ-B13/2-NA
FAZ-B15/2-NA
FAZ-B16/2-NA
FAZ-B20/2-NA
FAZ-B10/3-NA
FAZ-B13/3-NA
FAZ-B15/3-NA
FAZ-B16/3-NA
FAZ-B20/3-NA
25
30
32
35 C
40 C
FAZ-B25/1-NA
FAZ-B30/1-NA
FAZ-B32/1-NA
FAZ-B35/1-NA
FAZ-B40/1-NA
FAZ-B25/2-NA
FAZ-B30/2-NA
FAZ-B32/2-NA
FAZ-B35/2-NA
FAZ-B40/2-NA
FAZ-B25/3-NA
FAZ-B30/3-NA
FAZ-B32/3-NA
FAZ-B35/3-NA
FAZ-B40/3-NA
Amperes
Single-Pole A2 Two-Pole AThree-Pole A
Catalog Number Catalog Number Catalog Number
C Curve (5–10X In Current Rating)
0.5
1
1.5
2
3
FAZ-C0.5/1-NA-SP
FAZ-C1/1-NA-SP
FAZ-C1.5/1-NA-SP
FAZ-C2/1-NA-SP
FAZ-C3/1-NA-SP
FAZ-C0.5/2-NA
FAZ-C1/2-NA
FAZ-C1.5/2-NA
FAZ-C2/2-NA
FAZ-C3/2-NA
FAZ-C0.5/3-NA
FAZ-C1/3-NA
FAZ-C1.5/3-NA
FAZ-C2/3-NA
FAZ-C3/3-NA
4
5
6
7
8
FAZ-C4/1-NA-SP
FAZ-C5/1-NA-SP
FAZ-C6/1-NA-SP
FAZ-C7/1-NA-SP
FAZ-C8/1-NA-SP
FAZ-C4/2-NA
FAZ-C5/2-NA
FAZ-C6/2-NA
FAZ-C7/2-NA
FAZ-C8/2-NA
FAZ-C4/3-NA
FAZ-C5/3-NA
FAZ-C6/3-NA
FAZ-C7/3-NA
FAZ-C8/3-NA
10
13
15
16
20
FAZ-C10/1-NA-SP
FAZ-C13/1-NA-SP
FAZ-C15/1-NA-SP
FAZ-C16/1-NA-SP
FAZ-C20/1-NA-SP
FAZ-C10/2-NA
FAZ-C13/2-NA
FAZ-C15/2-NA
FAZ-C16/2-NA
FAZ-C20/2-NA
FAZ-C10/3-NA
FAZ-C13/3-NA
FAZ-C15/3-NA
FAZ-C16/3-NA
FAZ-C20/3-NA
25
30
32
35 C
40 C
FAZ-C25/1-NA-SP
FAZ-C30/1-NA-SP
FAZ-C32/1-NA-SP
FAZ-C35/1-NA-SP
FAZ-C40/1-NA-SP
FAZ-C25/2-NA
FAZ-C30/2-NA
FAZ-C32/2-NA
FAZ-C35/2-NA
FAZ-C40/2-NA
FAZ-C25/3-NA
FAZ-C30/3-NA
FAZ-C32/3-NA
FAZ-C35/3-NA
FAZ-C40/3-NA
A In = Rated current for instantaneous trip characteristics.
Amperes
Single-Pole A2 Two-Pole AThree-Pole A
Catalog Number Catalog Number Catalog Number
D Curve (10–20X In Current Rating)
0.5
1
1.5
2
3
FAZ-D0.5/1-NA-SP
FAZ-D1/1-NA-SP
FAZ-D1.5/1-NA-SP
FAZ-D2/1-NA-SP
FAZ-D3/1-NA-SP
FAZ-D0.5/2-NA
FAZ-D1/2-NA
FAZ-D1.5/2-NA
FAZ-D2/2-NA
FAZ-D3/2-NA
FAZ-D0.5/3-NA
FAZ-D1/3-NA
FAZ-D1.5/3-NA
FAZ-D2/3-NA
FAZ-D3/3-NA
4
5
6
7
8
FAZ-D4/1-NA-SP
FAZ-D5/1-NA-SP
FAZ-D6/1-NA-SP
FAZ-D7/1-NA-SP
FAZ-D8/1-NA-SP
FAZ-D4/2-NA
FAZ-D5/2-NA
FAZ-D6/2-NA
FAZ-D7/2-NA
FAZ-D8/2-NA
FAZ-D4/3-NA
FAZ-D5/3-NA
FAZ-D6/3-NA
FAZ-D7/3-NA
FAZ-D8/3-NA
10
13
15
16
20
FAZ-D10/1-NA-SP
FAZ-D13/1-NA-SP
FAZ-D15/1-NA-SP
FAZ-D16/1-NA-SP
FAZ-D20/1-NA-SP
FAZ-D10/2-NA
FAZ-D13/2-NA
FAZ-D15/2-NA
FAZ-D16/2-NA
FAZ-D20/2-NA
FAZ-D10/3-NA
FAZ-D13/3-NA
FAZ-D15/3-NA
FAZ-D16/3-NA
FAZ-D20/3-NA
25
30
32
35 C
40 C
FAZ-D25/1-NA-SP
FAZ-D30/1-NA-SP
FAZ-D32/1-NA-SP
FAZ-D35/1-NA-SP
FAZ-D40/1-NA-SP
FAZ-D25/2-NA
FAZ-D30/2-NA
FAZ-D32/2-NA
FAZ-D35/2-NA
FAZ-D40/2-NA
FAZ-D25/3-NA
FAZ-D30/3-NA
FAZ-D32/3-NA
FAZ-D35/3-NA
FAZ-D40/3-NA
A For ring tongue terminals, remove suffix NA and add suffix RT.
B For single packaging on single-pole C and D curves only, add suffix SP when ordering.
C 240 Vac only.
Breaker Family
FAZ = FAZ UL
circuit breaker Number of Poles
1 = Single-pole
2 = Two-pole
3 = Three-pole
Trip Characteristic
B = 3–5X In A
C = 5–10X In A
D = 10–20X In A
Terminal
NA = UL 489 branch circuit
with screw terminals
RT = UL 489 branch circuit
with ring tongue terminals
DC = UL 489 branch circuit at
125 Vdc per pole
Ampere Rating
0.5 = 0.5A
1 = 1A
1.5 = 1.5A
2 = 2A
3 = 3A
4 = 4A
5 = 5A
6 = 6A
7 = 7A
8 = 8A
10 = 10A
13 = 13A
15 = 15A
16 = 16A
20 = 20A
25 = 25A
30 = 30A
32 = 32A
35 = 35A
40 = 40A
Single Packaging
SP = Single packaging
for C and D curve,
single-pole only
Blank = Standard packaging