Power + * INNOVATION SOLUTIONS * SUPPORT * RELIABILITY * Up to 1500W output * Up to 16 outputs * Voltages up to 48V, Current up to 300 Amps * Fast-on output connection * Worldwide approvals & CB report * Medical Approval Option * 3 Year Warranty Alpha Key Market Segments & Applications 400, 600, 1000 & 1500 Watts Modular INPUT Input Frequency Inrush Current Input Fuse Leakage Current Lower Leakage Option Power Factor OUTPUT Turn on Delay Rise Time Turn on Overshoot Efficiency Hold up Ripple & Noise Voltage Accuracy Remote Sense Minimum Load Temperature Coefficient Load Regulation Line Regulation Cross Regulation Transient Response Recovery Over Voltage Protection Over Current Protection Short Circuit Protection Over Temperature Protection Broadcast ATE Industrial Computing Lifesciences/Laboratory Alpha 400 90 - 264Vac Alpha 600 90 - 264Vac, 160 - 358Vdc Alpha 1000 85 - 264Vac, 120 - 360Vdc Alpha 1500 85 - 264Vac (1000W below 150Vac input) 47 - 63Hz (440Hz with reduced PFC - consult factory) <50A at 25C and 264Vac (cold start) 250Vac HBC Fast Acting (not user accessible) 10A for 400W 12A for 600W 20A for 1000W and 1500W 1.1mA max at 264Vac & 63Hz see configuring guide 0.99 typical Input Voltage Voltage / Current Instrumentation Medical Automation Security Network Servers and Routers See module output table 1.5s max <50ms at 90Vac (150Vac for Alpha 1500W) & 100% rated output power to 90% of voltage, monotonic rise above 10% <5% or 250mV Load type dependant, no overshoot with resistive load 75% 15ms min <2% <1% Yes No <0.02% typical at 230Vac & 100% rated power, config dependent at 90Vac & 100% rated output power 13ms for 1000W, 8ms for 1500W and at 207Vac for 1500W (or 100mV if greater) Pk- Pk, using EIAJ test method & 20MHz bandwidth of set Voltage Standard on single output modules on any output of rated voltage per C <0.5% or 25mV for 0-100% load change (with sense connected, <2% without) <0.5% for 90 - 264Vac input change (210-264Vac for 1500W) <10% of set voltage for 50% load change (above 25% load) <0.2% 500s Standard Standard <150% Yes for 100% load change on any other output for recovery to 1% or 100mV of set voltage (1000s for S module) for all outputs for all outputs of rated current, when output voltage <1% Shuts down all outputs. Cycle ac off / on to reset Note shutdown temp varies according to ambient, output power and input V ALPHA SERIES Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 1 SAFETY APPROVALS Date EN 60950-1 2001 CSA22.2 No 60950-1 2003 UL 60950-1 Amendments 1988 CSA 60601-1a 2003 UL 60601-1a 2003 IEC60950-1* Date IEC 60601-1a 2001 2003 CE Mark * CB Certificate and report available on request Amendments A1, A2 LV Directive 2006/95/EC (EN60950-1) a - Only for LL, RL and TL leakage variants. CA400 + CA1000 only PRODUCT, GENERIC & COLLATERAL STANDARDS Low Voltage Power Supply, EMC Compliant to High Severity Immunity EN61601-1-2: 2001 Compliant EN61204-3: 2001 Medical Electrical Equipment, EMC Immunity for residential, commercial and light industrial environments Immunity for industrial environments Emissions for residential, commercial and light industrial environments Emissions for industrial environments Class A emissions for CA1000 / CA1500 EN61000-6-1: 2001 Compliant EN61000-6-2: 2001 Compliant EN61000-6-3: 2001 Compliant CA1000 and CA1500 not compliant EN61000-6-4: 2001 Compliant EMISSIONS Radiated Electric Field EN55022 Class B (as per CISPR.22) See application note for details. Class B (as per CISPR.22) Only for `S' type leakage versions. `M' & `L' types meet Class A Class A for Alpha 1000/1500 Conducted Emissions EN55022 Class A for Alpha 1000/1500 Conducted Harmonics EN61000-3-2: 2001 Flicker Class A emissions for CA1000 / CA1500 Compliant to Class A EN61000-3-3: 1995 + A1:2001 Compliant - dmax only. Only for `S' type leakage versions IMMUNITY Electrostatic Discharge EN61000-4-2 Level 4 Electromagnetic Field EN61000-4-3 Level 3 Fast / Burst Transient EN61000-4-4 Level 4 Surge Immunity EN61000-4-5 Level 3 Conducted RF Immunity EN61000-4-6 Level 3 Power Frequency Magnetic Field EN61000-4-8 Voltage Dips, Variation, EN61000-4-11 Interruptions Voltage Fluctuations EN61000-4-14 Level 4 Air discharge Contact discharge A 30A Continuous A A 10V (tested to 12V) Class 3 Class 3 Low Temperature Start-up -20C Shock Vibration Altitude Pollution IP Rating ISOLATION Input to Output Input to Earth A A A B for 5s interruptions For 100 to 240V nominal 0C to 70C operational, -40 to 85C storage (max 12 months) Humidity A 10V/m (tested to 12V/m) Input 4kV Outputs 2kV, Tested at 5kHz and 100kHz Line to Line (Differential) 1.1kV Line to Earth (Common Mode) 2.2kV ENVIRONMENT Temperature Derating Criteria 15kV 8kV A 50C to 70C derate each output by 2.5% per C 5-95% RH non condensing 3000 shocks, each of 10g (16ms) half sine 10 - 200Hz @ 1.5g 3,000 metres operational (15,000 metres non operational) Degree 2, Material group 3 IP 10 Reinforced Basic 4.3 kV (dc) 2.3 kV (dc) Output to Earth Output to Output ALPHA SERIES Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 Operational Operational 500 V (dc) 500 V (dc) 2 OUTPUT VOLTAGES (single output modules) Adjustment Module Amps Slots (twin output modules) Module V1 Adjustment A 4.5 - 5.5 60 2 B 4.5 - 5.5 25 1 EQ 1 P AA 4.5 BB 4.5 C 5 D 18 G 17.5 K 18 F J 9 30 L 1.8 N 18 M 5 Q 2.7 S 2.5 R T U W Z 2.7 1.8 10 4.5 4.5 - 6.5 6.5 25 16a 16 29 8 16 29 33 25b 29 15 10c 48 - 3.2 - 32 - 60 25 16 8 5d - 3.9 25 - 5.7 85 - 3.9 60 3.2 60 21 16 5.5 15 5.5 25 E 2 1 5 - 4.5 - EB 4.5 H 18 1 18 16 8 5.5 9 - 5.5 - 32 - Amps 29 V2 Adjustment 5 - 2.7 - 9 4.5 5 18 5 5 Amps Slots 16 8 1 3.9 9 1 - 5.5 - 32 - 16 9 5 8 1 1 1 2 2 2 2 1 1 1 1 2 2 2 a) 12A max above 12V 1 b) 21A max above 24.5V c) Derate output current by 0.25A / V above 40V d) 1A max above 29V 1 1 Alpha Configuring Guide The extensive range of output modules and options make it possible to achieve many combinations of Volts and Amps. To achieve the optimum configuration, please contact our sales office. However you can also create your own configuration from this datasheet by using the guide below. Configuring from Datasheet 1 Calculate total output power to determine Alpha 400W, 600W, 1000W or 1500W and select converter, then select required Cooling and Leakage Current from the following table:- CA 400 Output Power 400 600 1000 1500 (5 (5 (7 (8 Cooling empty QFa RAb Forward air - Standard Forward air - Quiet fan Reverse air QF LL slots) slots) slots) slots) Earth Leakage Current (at 264Vac, 63Hz) empty ML LL RL TL Standard 1.1 mA 500A 240A 110A 50A Notes: a) CA400/600 only. CA400 derates to 300W, CA600 derates to 475W b) Contact sales office for details 2 Select Output Modules and Options from the Output Voltages tables. Example - if you require 5.2V / 18A with output inhibit : a) select B as closest match for voltage and current and prefix with voltage (e.g. 5.2B) b) add suffix for option (if required) `_PA' for parallel/current share (for N+1 redundant applications) `_PP' for parallel (increase current from one PSU) `_IN' for inhibit `_RP' for remote programming `_MF' (only applicable on 1st module) for global inhibit, ac fail and 5V/50mA standby supply c) repeat for other outputs Ensure that the total width of all selected modules is within the slots for the chosen converter. For example:- CA600LL 5A 12/12E 24D which represents a four output 600W Alpha with Forward air, 240A Earth Leakage, with:Output 1 = 5V / 60A with remote sense Output 2 = 12V / 8A Output 3 = 12V / 8A Output 4 = 24V / 8A with remote sense 3 Contact TDK-Lambda to validate configuration and issue a part number. ALPHA SERIES Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 3 Option Connections 4 1 5 2 6 3 IN, PA, PP, RP Option 1 slot, 2 output 1 slot, 1 output + 2 slot, 1 output + + - - Pin IN option PA option PP option RP option MF option 1 n/c + Sense + Sense + Sense Inhibit (low) 2 Module Good Module Good n/c - Sense 5V supply 3 Inhibit Star point n/c Control 2 Power Fail 4 n/c - Sense - Sense n/c 0V 5 - Power - Power n/c Control 1 Inhibit (high) 6 - Power Star point n/c n/c n/c + - + - + - Remote sense MF option - 6 5 4 3 2 1 Alpha 400 Alpha 600 ALPHA SERIES Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 4 Alpha 1000 Alpha 1500 ALPHA SERIES Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 5 TDK-LAMBDA EMEA AUSTRIA TDK-LAMBDA GERMANY GmbH Aredstrae 22 A-2544 Leobersdorf Telephone: Facsimile: Web: +43 (0) 2256 655 84 +43 (0) 2256 645 12 www.lambda-austria.com FRANCE TDK-LAMBDA FRANCE SAS ZAC des Delaches, BP1077 - Gometz le Chatel 91940 Les Ulis Telephone: Facsimile: Web: +33 (0) 1 60 12 71 65 +33 (0) 1 60 12 71 66 www.lambda-f.com GERMANY TDK-LAMBDA GERMANY GmbH Karl-Bold-Strae 40 D-77855 Achern Telephone: Facsimile: Web: +49 (0) 78 41 666 0 +49 (0) 78 41 5000 www.lambda-germany.com ISRAEL NEMIC LAMBDA LTD Kibbutz Givat Hashlosha 48800 Telephone: Facsimile: Web: +972 (0) 3 902 4333 +972 (0) 3 902 4777 www.nemic.co.il ITALY TDK-LAMBDA ITALY s.r.l. Via dei Lavoratori 128/130, 20092, Cinisello Balsamo (Mi) Telephone: Facsimile: Web: +39 (0) 02 61 29 38 63 +39 (0) 02 61 29 09 00 www.lambda-italy.com SWEDEN TDK-LAMBDA SCANDINAVIA PO Box 546, Rallervagen 41 SE-184 25. Akersberga Telephone: Facsimile: Web: +46 (0) 8 598 94 090 +46 (0) 8 540 66 096 www.lambda-scandinavia.com UK TDK-LAMBDA UK Kingsley Avenue Ilfracombe Devon EX34 8ES Telephone: Facsimile: Web: +44 (0) 1271 856666 +44 (0) 1271 864894 www.lambda-gb.com TDK-LAMBDA NORTH AMERICA visit http://us.tdk-lambda.com/ for a list of TDK-Lambda offices and distributors TDK-LAMBDA ASIA visit http://www.tdk-lambda.com/ for a list of TDK-Lambda offices and distributors LOCAL DISTRIBUTION ALPHA SERIES Alpha Datasheet - Document Number 69698 - Rev 3.3 October 08 6 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TDK-Lambda: CA400 J40029