www.mccsemi.com
MBR30100PT
30 Amp
Features
Metal of siliconrectifier , majonty carrier conduction
Guard ring for transient protection
MCC
Catalog
Number
Maximum
Re current
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MBR 30100PT 100 V 70V 100 V
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
IF(AV) 30 A TC=100°C
Peak Forward Surge
Current
IFSM 200A 8.3ms, half
Maximum
Instantaneous
Forward Voltage
MCC
*Pulse Test: Pulse Width38 0µsec, Duty Cycle 2%
100Volts
TO-247
Maximum Ratings
Operating J unction Temperature : 150 °C
Storage Temperature: - 5 0°C to +150°C
omponents
20736 Marilla Street Chatsworth

 !"#
$%  !"#
Barrier Rectifier
Schottky
Maximum
Reverse Current At
Rated DC Blocking
Voltage
IR 500 µA T
J = 25°C
7m A T
J = 125°C
V
F .85V I
FM = 15A
T
J = 25°C
sine wave
Revision: 2 2004/03/08
PIN 1
PIN 3
PIN 2
CASE
E
G
J
C
K
A
B
Q
D
V
F
P
PIN
123

INCHES MM
     
A .803 .856 20.40 21.75
B .608 .640 15.44 16.25
C .185 .205 4.70 5.21
D .043 .051 1.09 1.30
E .059 .082 1.50 2.08
F .071 .086 1.80 2.18
J .019 .030 0.48 0.76
K .772 .791 19.60 20.10
P .122 .172 3.10 4.38
Q .138 .145 3.50 3.70
V .115 .134 2.93 3.40
B .205 .224 5.20 5.70
Low power loss high efficiency
High surge capacity , High current capability
TM
Micro Commercial Components
RATING AND CHARACTERISTIC CURVES
MBR30100PT
www.mccsemi.com
MCC
Revision: 1 2004/03/08
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
Amps
.5
1
10
100
200
0 0.5 1.0 1.5 2.0 2.5
25°C
Figure 2
Typical Reverse Characteristics
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
0.0001
mAmps
0.001
0.01
0.1
1.0
10
0 20 40 60 80 100
25°C
50°C
125°C
Forward Current Derating Curve
25
75 100 125 150 175
10
050
40
30
0
20
Resistive Or
Inductive Load
Figure 3
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
Amps
1 100
4
0
50
100
150
8
Figure 4
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2610 20 60 80
40
300
200
TM
Micro Commercial Components