RECOMMENDED OPERATING CONDITIONS
Soldering iron: Good results should be obtained using a range
of tip temperatures. However, the optimum tip temperature and
heat capacity required for a hand soldering process is a function
of both soldering iron design and the nature of the task and care
should be exercised to avoid unnecessarily high tip temperatures
for excessive times. A high tip temperature will increase any
tendency to flux spitting and it may produce some residue
darkening.
The soldering iron tip should be properly tinned and this may be
achieved using Multicore cored wire. Severely contaminated
soldering iron tips should first be cleaned and pre-tinned using
Multicore Tip Tinner/Cleaner TTC1, then wiped on a clean, damp
sponge before re-tinning with Multicore cored wire.
Soldering process: Multicore cored wires contain a careful
balance of resins and activators to provide clear residues,
maximum activity and high residue reliability, without cleaning in
most situations. To achieve the best results from Multicore solder
wires, recommended working practices for hand soldering should
be observed as follows:
• Apply the soldering iron tip to the work surface, ensuring that
it simultaneously contacts the base material and the
component termination to heat both surfaces adequately.
This process should only take a fraction of a second.
• Apply Multicore flux cored solder wire to a part of the joint
surface away from the soldering iron and allow to flow
sufficiently to form a sound joint fillet – this should be
virtually instantaneous. Do not apply excessive solder or
heat to the joint as this may result in dull, gritty fillets and
excessive or darkened flux residues.
• Remove solder wire from the work piece and then remove
the iron tip.
The total process will be very rapid, depending upon thermal
mass, tip temperature and configuration and the solderability of
the surfaces to be joined.
Multicore flux cored solder wires provide fast soldering on copper
and brass surfaces as well as solder coated materials. The good
thermal stability of Multicore fluxes means they are also well
suited to soldering applications requiring high melting temperature
alloys.
Cleaning: Multicore X39 flux cored wires have been formulated
to leave minimal quantities of flux residue and to resist spitting
and fuming.
Cleaning will not be required in most situations but if necessary
this is best achieved using Multicore MCF800 Cleaner (see
separate technical data sheet). Other proprietary solvent or semi-
aqueous processes may be suitable. Saponification may be
viable but customers must ensure that the desired level of
cleanliness can be achieved by their chosen system
HEALTH AND SAFETY
WARNING: The following information is for guidance only and
users must refer to the Material Safety Data Sheets relevant to
specific Multicore X39 products before use.
Health Hazards and Precautions: Inhalation of the flux fumes given
off during soldering should be avoided. The fumes are irritating to the
throat and respiratory system. Prolonged or repeated exposure to
rosin or modified rosin based flux fumes may lead to the development
of respiratory sensitisation and occupational asthma.
Multicore solder wires must always be used with suitable fume
extraction equipment to remove fumes from the breathing zone of
operators and the general work environment.
Solder alloys containing lead give off negligible fume at normal
soldering temperatures up to 500°C.
Normal handling of lead alloy wires will not cause lead to be
absorbed through the skin. The most likely route of entry is
through ingestion but this will not be significant if a good standard
of personal hygiene is maintained. Eating, drinking and smoking
should not be permitted in the working area. Hands should be
washed with soap and warm water after handling solder wire.
Waste disposal: Wherever possible, waste solder wire should
be recycled for recovery of metal. Otherwise it should be
disposed of according to local or national regulations.
Note
The data contained herein are furnished for information only and
are believed to be reliable. We cannot assume responsibility for
the results obtained by others over whose methods we have no
control. It is the user's responsibility to determine suitability for
the user's purpose of any production methods mentioned herein
and to adopt such precautions as may be advisable for the
protection of property and of persons against any hazards that
may be involved in the handling and use thereof. In light of the
foregoing, Henkel Corporation specifically disclaims all
warranties expressed or implied, including warranties of
merchantability or fitness for a particular purpose, arising
from sale or use of Henkel Corporation’s products. Henkel
Corporation specifically disclaims any liability for
consequential or incidental damages of any kind, including
lost profits. The discussion herein of various processes or
compositions is not to be interpreted as representation that they
are free from domination of patents owned by others or as a
license under any Henkel Corporation patents that may cover
such processes or compositions. We recommend that each
prospective user test his proposed application before repetitive
use, using this data as a guide. This product may be covered by
one or more United States or foreign patents or patent
applications.
NOT FOR PRODUCT SPECIFICATIONS
THE TECHNICAL INFORMATION CONTAINED HEREIN ARE INTENDED AS REFERENCE ONLY:
PLEASE CONTACT HENKEL TECHNOLOGIES FOR ASSISTANCE AND RECOMMENDATIONS
ON SPECIFICATIONS FOR THIS
HENKEL LOCTITE ADHESIVES LTD. , KELSEY HOUSE, WOODLANE END. HEMEL
HEMPSTEAD, HERTFORDSHIRE HP2 4RQ, UK, TEL. +44 1442 233 233, FAX +44 1442 269 554
ll trademarks, except where noted, are the property of Henkel Corp. U.S.A