www.tracopower.com
DC/DC Converters
TES 2M Series 2 Watt
Input Specifications
Input current no load 5 Vin models: 60 mA typ.
12 Vin models: 30 mA typ.
24 Vin models: 15 mA typ.
Reverse voltage protection 0.3 A max.
Recommended input fuse (slow blow) 5 Vin models: 1.0 A
12 Vin models: 0.5 A
24 Vin models: 0.2 A
Surge voltage (1 sec. max.) 5 Vin models: 9 V max.
12 Vin models: 18 V max.
24 Vin models: 30 V max.
Input filter internal capacitors
Output Specifications
Voltage set accuracy ±4 %
Voltage balance (dual output models) 1 % max.
Regulation – Input variation 1.2 % / 1 % change of Vin
– Load variation 20 – 100 % 10 % max.
12 % max. for 5 Vout models.
Ripple and noise (0–20 MHz Bandwidth) 150 mVp-p max.
Temperature coefficient ±0.02 %/K
Short circuit protection 0.5 sec. max. (automatic recovery)
Minimum load 2 % of rated max current.
Capacitive load single output models: 330 µF max.
dual output models: 100 µF max. (each output)
General Specifications
Temperature ranges – Operating –25°C to +80°C
– Storage –55°C to +125°C
– Case temperature +90°C max.
Derating 2.5 %/K above 60°C
Humidity (non condensing) 95 % rel. H max.
Reliability, calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >2.0 Mio h
Isolation voltage (50Hz, 60sec.) – Input/Output 4000 VACrms (reinforced)
Isolation test voltage (1 sec.) 6000 Vpk
Leakage current (at 240VAC, 60Hz) 2 µA max.
Isolation capacitance – Input/Output 20 pF max. (at 100KHz, 1V)
Isolation resistance – Input/Output >10 Gohm (at 500VDC)
Safety approvals IEC/EN 60950-1, IEC/EN 60601-1 3rd Edition,
ANSI/AAMI ES60601-1 and CAN/CSA-C22.2
No. 60601-1, Medical Electrical Equipment -
Part 1: General Requirements for Basic Safety
and Essential Performance
– Certification documents www.tracopower.com/overview/tes2m
Switching frequency 50 – 100 kHz (PFM)
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS directive 2011/65/EU
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
Page 2 of 3