PPS-125 125W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function Protections: Short circuit / Overload / Over voltage PWM control and regulated High power density 6.117W/inch Built-in remote sense function LED indicator for power on 100% full load burn-in test 125W with 18CFM FAN 5"x3" compact size 3 years warranty 3 Bauar t gepruft Sicherheit egel ma ge o s od g be wac SPECIFICATION www. tuv.com ID 2000000000 MODEL OUTPUT PPS-125-3.3 PPS-125-5 PPS-125-12 PPS-125-13.5 PPS-125-15 PPS-125-24 PPS-125-27 DC VOLTAGE 3.3V 5V 12V 13.5V 15V 24V 27V 48V RATED CURRENT 20A 20A 8.5A 7.5A 6.7A 4.2A 3.8A 2.1A CURRENT RANGE (convection) 0 ~ 20A 0 ~ 20A 0 ~ 8.5A 0 ~ 7.5A 0 ~ 6.7A 0 ~ 4.2A 0 ~ 3.8A 0 ~ 2.1A CURRENT RANGE (18CFM FAN) 0 ~ 25A 0 ~ 25A 0 ~ 10.5A 0 ~ 9.3A 0 ~ 8.4A 0 ~ 5.2A 0 ~ 4.6A 0 ~ 2.6A RATED POWER (convection) 66W 100W 102W 101.25W 100.5W 100.8W 102.6W 100.8W RATED POWER (18CFM FAN) 82.5W 125W 126W 125.55W 126W 124.8W 124.2W 124.8W RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p VOLTAGE ADJ. RANGE 4.75 ~ 5.25V 2.0% 11.40 ~ 12.60V 12.82 ~ 14.17V 14.25 ~ 15.75V 22.80 ~ 25.20V 25.65 ~ 28.35V 45.60 ~ 50.40V 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% SETUP, RISE TIME 1000ms, 30ms/230VAC HOLD UP TIME (Typ.) 20ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47~63Hz POWER FACTOR (Typ.) PF>0.93/230VAC EFFICIENCY (Typ.) 70% 79% 83% 83% 84% 1.2A 1.7A 115VAC 230VAC INRUSH CURRENT (Typ.) 20ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 0.6A 0.75A COLD START 40A/230VAC 80% 80% 80% LEAKAGE CURRENT <2mA / 240VAC OVERLOAD 130 ~ 160% rated output power Protection type : Fold back current limiting, recovers automatically after fault condition is removed PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY & WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC (Note 4) EMC EMISSION EMC IMMUNITY MTBF NOTE 2000ms, 30ms/115VAC at full load ND AC CURRENT (Typ.) OTHERS NR 3.13 ~ 3.46V VOLTAGE TOLERANCE Note.3 2.0% INPUT PPS-125-48 DIMENSION PACKING 3.63 ~ 4.45V 5.5 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 20.25V 17.25 ~ 20.25V 27.6 ~ 32.4V 31.05 ~ 36.45V 57.6 ~ 67.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed -20 ~ +70 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH 0.05%/ (0 ~ 50) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A 111.7Khrs min. MIL-HDBK-217F (25) 127*76.2*34.6mm (L*W*H) 0.37Kg; 36pcs/14.3Kg/0.79CUFT 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Heat Sink HS1,HS2 & HS3 can not be shorted. File Name:PPS-125-SPEC 2017-07-07 PPS-125 125W Single Output with PFC Function Mechanical Specification series Unit:mm 127 6.4 5 115.6 M2 HS3 AC Input Connector (CN1) : JST B3P-VH or equivalent SVR1 FS1 T2A 250VAC 64.8 76.2 HS1 1 2 3 CN1 LED1 1 CN3 2 1 2 3 4 5 6 7 8 HS2 Assignment AC/L No Pin AC/N Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent DC Output Connector (CN5) : JST B8P-VH or equivalent Pin No. 1~4 5~8 Assignment -V +V Mating Housing Terminal JST VHR or equivalent JST SVH-21T-P1.1 or equivalent Remote Sense(CN3) : Molex 5045-02 or equivalent CN5 M1 Pin No. 1 2 3 43. 5 Air flow direction Pin No. 1 2 Assignment RS+ RS- Mating Housing Terminal Molex 5051 or equivalent Molex 4809 or equivalent 1.HS1,HS2& HS3 cannot be shorted. 2.M1 is safety ground. For better EMC performance,Please secure an electrical connection between M1,M2 and chassis grounding. ND 3max. NR 34.6 : Grounding Required Block Diagram EMI FILTER & RECTIFIERS I/P PFC CIRCUIT RECTIFIERS & FILTER POWER SWITCHING FG O.L.P. Derating Curve O.V.P. Output Derating VS Input Voltage 100 Forced air 18CFM 90 100 Free air Convection 80 70 70 50 60 LOAD(%) LOAD (%) +V -V FEEDBACK DETECTION CIRCUIT PWM & PFC CONTROL 125 20 -20 fosc : 100KHz 0 10 20 25 30 40 50 AMBIENT TEMPERATURE () 60 70 (HORIZONTAL) 50 40 90 100 115 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:PPS-125-SPEC 2017-07-07