TEMPFET® BTS 132
1 19.02.04
3
2
1
Features
N channel
Logic level
Enhancement mode
Temperature sensor with thyristor characteristic
The drain pin is electrically shorted to the tab
Pin 1 2 3
GDS
Type VDS IDRDS(on) Package Ordering Code
BTS 132 60 V 24 A 0.065 TO-220AB C67078-A5003-A4
Maximum Ratings
Parameter Symbol Values Unit
Drain-source voltage VDS 60 V
Drain-gate voltage, RGS = 20 kVDGR 60
Gate-source peak voltage, aperiodic Vgs ± 20
Gate-source voltage VGS ± 10
Continuous drain current, TC = 25 °CID24 A
ISO drain current
TC = 85 °C, VGS = 10 V, VDS = 0.5 V
ID-ISO 6.0
Pulsed drain current, TC = 25 °CID puls 96
Short circuit current, Tj = – 55 ... + 150 °CISC 80
Short circuit dissipation, Tj = – 55 ... + 150 °CPSCmax 1200 W
Power dissipation Ptot 75
Operating and storage temperature range Tj,Tstg – 55 ... + 150 °C
DIN humidity category, DIN 40 040 E
IEC climatic category, DIN IEC 68-1 55/150/56
Thermal resistance
Chip-case
Chip-ambient
Rth JC
Rth JA
1.67
75
K/W
TEMPFET® BTS 132
2 19.02.04
Electrical Characteristics
at Tj = 25 °C, unless otherwise specified.
Parameter Symbol Values Unit
min. typ. max.
Static Characteristics
Drain-source breakdown voltage
VGS = 0, ID = 0.25 mA
V(BR)DSS 60 ––
V
Gate threshold voltage
VGS = VDS, ID = 1 mA
VGS(th) 1.5 2.0 2.5
Zero gate voltage drain current
VGS = 0 V, VDS = 60 V
Tj = 25 °C
Tj = 125 °C
IDSS
1
100
10
300
µA
Gate-source leakage current
VGS = 20 V, VDS = 0
Tj = 25 °C
Tj = 150 °C
IGSS
10 100 nA
µA
Drain-source on-state resistance
VGS = 4.5 V, ID =12 A
RDS(on) 0.055 0.065
Dynamic Characteristics
Forward transconductance
VDS 2 ×ID×RDS(on)max,ID = 12 A
gfs 12 17 22
S
Input capacitance
VGS = 0, VDS = 25 V, f = 1 MHz
Ciss 800 1050 1400
pF
Output capacitance
VGS = 0, VDS = 25 V, f = 1 MHz
Coss 500 750
Reverse transfer capacitance
VGS = 0, VDS = 25 V, f = 1 MHz
Crss 200 300
Turn-on time ton, (ton = td(on) + tr)
VCC = 30 V, VGS = 5 V, ID = 3 A, RGS = 50
td(on) 25 40 ns
tr150 200
Turn-off time toff, (toff = td(off) + tf)
VCC = 30 V, VGS = 5 V, ID = 3 A, RGS = 50
td(off) 180 250
tf125 160
TEMPFET® BTS 132
3 19.02.04
Electrical Characteristics (contd)
at Tj = 25 °C, unless otherwise specified.
Parameter Symbol Values Unit
min. typ. max.
Reverse Diode
Continuous source current IS––24 A
Pulsed source current ISM ––96
Diode forward on-voltage
IF = 24 A, VGS = 0 V
VSD 1.3 1.8
V
Reverse recovery time
IF = IS, diF/dt = 100 A/µs, VR = 30 V
t rr 150
ns
Reverse recovery charge
IF = IS, diF/dt = 100 A/µs, VR = 30 V
Q rr 1.0
µC
Temperature Sensor
Forward voltage
ITS(on) = 5 mA, Tj = 55 ... + 150 °C
Sensor override, tp 100 µs
Tj = 55 ... + 160 °C
VTS(on)
1.3
1.4
10
V
Forward current
Tj = 55 ... + 150 °C
Sensor override, tp 100 µs
Tj = 55 ... + 160 °C
ITS(on)
5
600
mA
Holding current, VTS(off) = 5 V, Tj = 25 °C
Tj = 150 °C
IH0.05
0.05
0.1
0.2
0.5
0.3
Switching temperature
VTS = 5 V
TTS(on) 150 ––
°C
Turn-off time
VTS = 5 V, ITS(on) = 2 mA
toff 0.5 2.5
µs
TEMPFET® BTS 132
4 19.02.04
Examples for short-circuit protection
at Tj = 55 ... + 150 °C, unless otherwise specified.
Parameter Symbol Examples Unit
12
Drain-source voltage VDS 15 30 V
Gate-source voltage VGS 6.2 4.1
Short-circuit current ISC 80 37 A
Short-circuit dissipation PSC 1200 1100 W
Response time
Tj = 25 °C, before short circuit
tSC(off) 25 25
ms
Short-circuit protection ISC = f (VDS)
Parameter:V
GS
DiagramtodetermineISC forTj=55...+ 150 ˚C
Max. gate voltage VGS(SC) = f (VDS)
Parameter: Tj= 55 ... + 150 °C
TEMPFET® BTS 132
5 19.02.04
Max. power dissipation Ptot = f (TC)
Typical output characteristics ID = f (VDS)
Parameter:t
p =80µs
Typ. drain-source on-state resistance
RDS(on) = f (ID)
Parameter:V
GS
Safe operating area ID = f (VDS)
Parameter: D = 0.01, TC=25°C
TEMPFET® BTS 132
6 19.02.04
Drain-source on-state resistance
RDS(on) = f (Tj)
Parameter: ID= 12 A, VGS = 4.5 V (spread)
Typ. transfer characteristic
ID = f (VGS)
Parameter:t
p = 80 µs, VDS = 25 V
Gate threshold voltage VGS(th) = f (Tj)
Parameter:V
DS = VGS,ID= 1 mA
Typ. transconductance gfs = f (ID)
Parameter: tp = 80 µs, VDS = 25 V
TEMPFET® BTS 132
7 19.02.04
Continuous drain current ID=f (TC)
Parameter: VGS 4.5 V
Typ. gate-source leakage current
IGSS =f (TC)
Parameter: VGS = 10 V, VDS = 0
Forward characteristics of reverse diode
IF = f (VSD)
Parameter:T
j,tp = 80 µs (spread)
Typ. capacitances C = f (VDS)
Parameter: VGS = 0, f= 1 MHz
TEMPFET® BTS 132
8 19.02.04
Transient thermal impedance ZthJC = f (tp)
Parameter:D = tp/T
TEMPFET® BTS 132
9 19.02.04
TO 220 AB Ordering Code
Standard C67078-A5003-A4
3.7
9.5
9.9
4.6
0.75
1.05
2.542.54
17.5
2.8
12.8
0.5
2.4
13.5
9.2
15.6
1.3
4.4
GPT05155
1)
3) max. 14.5 by dip tinning press burr max. 0.05
2) dip tinning
1) punch direction, burr max. 0.04
3)
2) 1
TEMPFET® BTS 132
10 19.02.04
Edition 04.97
Published by Infineon Technologies AG,
St.-Martin-Strasse 53,
D-81541 München, Germany
©
Infineon Technologies AG 2000.
All Rights Reserved.
Attention please!
The information herein is given to describe certain components and shall not be considered as warranted
characteristics.
Terms of delivery and rights to technical change reserved.
We hereby disclaim any and all warranties, including but not limited to warranties of non-infringement, regarding
circuits, descriptions and charts stated herein.
Infineon Technologies is an approved CECC manufacturer.
Information
For further information on technology, delivery terms and conditions and prices please contact your nearest
Infineon Technologies Office in Germany or our Infineon Technologies Representatives worldwide (see address
list).
Warnings
Due to technical requirements components may contain dangerous substances. For information on the types in
question please contact your nearest Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or systems with the express written
approval of Infineon Technologies, if a failure of such components can reasonably be expected to cause the failure
of that life-support device or system, or to affect the safety or effectiveness of that device or system. Life support
devices or systems are intended to be implanted in the human body, or to support and/or maintain and sustain
and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may
be endangered.