SPECIFICATION CONTROL DRAWING
Tyco Electronics Corporation
300 Constitutional Drive
Menlo Park, CA 94025 USA
RAYCHEM
TITLE: SOLDERSLEEVE* DEVICE SHIELD
TERMINATION WITH LEADS, HIGH
TEMPERATURE IMMERSION RESISTANT
UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS.
INCHES DIMENSIONS ARE BETWEEN BRACKETS. DOCUMENT NO.: SO96-X-55-22-90
TOLERANCES:
0.00 N/A
0.0 N/A
0 N/A
ANGLES: N/A
ROUGHNESS IN
MICRON
Tyco Corporation reserves the right to amend this
drawing at any time. Users should evaluate the
suitability of the product for their application.
DATE:
09-Dec-99
DOC ISSUE:
5
DRAWN BY:
M. FORONDA
CAGE CODE:
06090
REPLACES:
D981806
DCR NUMBER:
D990981
PROD. REV.:
SEE TABLE
SCALE:
None
SIZE:
A
SHEET:
1 of 1
If this document is printed it becomes uncontrolled. Check for the latest revision.
Product Revision Product Dimensions Cable Dimensions
Product
Name
Ident
Code
L±1.75
(L±0.075)
øB
min
øC
min
H
min
øE
max
øF
min
øD
max
SO96-1-55-22-90 D SO961R 16.5
(0.650)
1.90
(0.075)
2.67
(0.105)
8.20
(0.322)
2.67
(0.105)
0.90
(0.035)
1.90
(0.075)
SO96-2-55-22-90 D SO962R 16.5
(0.650)
2.67
(0.105)
3.68
(0.145)
8.20
(0.322)
3.68
(0.145)
1.40
(0.055)
2.67
(0.105)
SO96-3-55-22-90 D SO963R 16.5
(0.650)
4.32
(0.170)
5.08
(0.200)
8.20
(0.322)
5.08
(0.200)
2.15
(0.085)
4.32
(0.170)
SO96-4-55-22-90 D SO964R 19.1
(0.750)
5.97
(0.235)
6.48
(0.255)
8.20
(0.322)
6.48
(0.255)
3.30
(0.130)
5.97
(0.235)
SO96-5-55-22-90 D SO965R 19.1
(0.750)
6.98
(0.275)
7.62
(0.300)
8.20
(0.322)
7.62
(0.300)
4.30
(0.170)
6.98
(0.275)
MATERIALS
1. INSULATION SLEEVE: Heat-shrinkable, transparent blue, radiation cross-linked modified polyvinylidene fluoride.
2. SOLDER PREFORM WITH FLUX AND THERMAL INDICATOR:
SOLDER: TYPE Sn96 per ANSI-J-STD-006.
FLUX: TYPE ROM1 per ANSI-J-STD-004.
THERMAL INDICATOR: Color change orange to colorless.
3. MELTABLE RINGS: Environment resistant thermoplastic. Color: blue.
4. PRE-INSTALLED LEAD: Raychem 55A0813-22-90 in accordance with MIL-W-22759/41-22-90 AWG22 stranded nickel
plated copper. Color: white stripped black.
APPLICATION
1. These parts are designed to an environment resistant shield termination on cables, rated for 150°C minimum, meeting the
dimensional criteria listed, having nickel-plated shields and insulations compatible with the insert material.
See MIL-S-83519/1 or consult Raychem.
2. Temperature range: -55°C to +175°C.
3. Parts shall be marked with identification code per table.
4. Install using Raychem-approved convection or infra-red heating tools in accordance with Raychem process standard
RCPS-100-70. Infrared tools are not recommended for use with black jackets.
For best results, prepare
the wire as shown:
* A trademark of Tyco Corporation