Short-circuit proof PCB transformer
VB
Typ
Terminals
Pin )
Core type
Weight
Dimension picture (in mm)
A B C D E F G H
VB 0,35/1/.. Pins for printed circuit boards 0.6 mm EE 20/6,1 0.02 kg 122 22.7 15 15 15 5 - 5
VB 0,35/2/.. Pins for printed circuit boards 0.6 mm EE 20/6,1 0.02 kg 222 22.7 15 15 15 5 5 5
VB 0,5/1/.. Pins for printed circuit boards 0.6 mm EE 20/10,5 0.04 kg 122 22.7 19 15 15 5 - 5
VB 0,5/2/.. Pins for printed circuit boards 0.6 mm EE 20/10,5 0.04 kg 222 22.7 19 15 15 5 5 5
VB 1,0/1/.. Pins for printed circuit boards 0.8 mm EI 30/10,5 0.07 kg 132.3 27.3 21.8 20 20 10 - 5
VB 1,0/2/.. Pins for printed circuit boards 0.8 mm EI 30/10,5 0.07 kg 232.3 27.3 21.8 20 20 10 5 5
VB 1,2/1/.. Pins for printed circuit boards 0.8 mm EI 30/12,5 0.08 kg 132.3 27.3 23.8 20 20 10 - 5
VB 1,2/2/.. Pins for printed circuit boards 0.8 mm EI 30/12,5 0.08 kg 232.3 27.3 23.8 20 20 10 5 5
VB 1,5/1/.. Pins for printed circuit boards 0.8 mm EI 30/12,5 0.08 kg 132.3 27.3 23.8 20 20 10 - 5
VB 1,5/2/.. Pins for printed circuit boards 0.8 mm EI 30/12,5 0.08 kg 232.3 27.3 23.8 20 20 10 5 5
VB 2,0/1/.. Pins for printed circuit boards 0.8 mm EI 30/15,5 0.10 kg 132.3 27.3 26.8 20 20 10 - 5
VB 2,0/2/.. Pins for printed circuit boards 0.8 mm EI 30/15,5 0.10 kg 232.3 27.3 26.8 20 20 10 5 5
VB 2,3/1/.. Pins for printed circuit boards 0.8 mm EI 30/18,0 0.11 kg 132.3 27.3 29 20 20 10 - 5
VB 2,3/2/.. Pins for printed circuit boards 0.8 mm EI 30/18,0 0.11 kg 232.3 27.3 29 20 20 10 5 5
VB 2,8/1/.. Pins for printed circuit boards 0.8 mm EI 30/23,0 0.14 kg 132.3 27.3 34 20 20 10 - 5
VB 2,8/2/.. Pins for printed circuit boards 0.8 mm EI 30/23,0 0.14 kg 232.3 27.3 34 20 20 10 5 5
VB 3,2/1/.. Pins for printed circuit boards 0.8 mm EI 38/16,5 0.17 kg 141 35 30.8 20 25 10 - 5
VB 3,2/2/.. Pins for printed circuit boards 0.8 mm EI 38/16,5 0.17 kg 241 35 30.8 20 25 10 5 5
30
Dimension pictures
Short-circuit proof PCB transformer
AVB
General Data
Rated input voltage 2 x 115 Vac
Rated output voltage 6 - 2 x 24 Vac
Rated power 0.35 - 3.2 VA
Insulation class B
Maximum ambient temperature 70 °C (AVB 3,2 max. 50 °C)
Efficiency up to 59 %
Degree of protection IP 00
Advantages
Minimum size at high output
Inherently short-circuit proof
Dual input voltage for series or parallel connection
Also with dual output voltage for series or parallel connection
Designed for high ambient temperatures
Permanent corrosion protection, high insulation value and maximum
electrical reliability thanks to XtraDenseFill resin encapsulation
Self-extinguishing potting and hood material
Applications
As a mains transformer for adjustment of the voltage and simple electrical
isolation.
As a safety transformer for the safe electrical isolation of the input and output
sides. The transformer is suitable for creating SELV and PELV circuits because
of the limit on the output voltage.
Sample application
Standards & 1 Z
Approvals W J Z
Mains transformer
to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL
5085-1/-2, CSA 22.2 No.66
Safety isolating transformer
to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL
5085-1/-2, CSA 22.2 No.66
UL 5085-1/-2, CSA 22.2 No.66
Transformers
PCB transformers
1
BLOCK
Website
253
Subject to change
1.1
1.2
5.1
1.3
2.1
2.2
3.1
3.2
3.3
5.2
4.0
Short-circuit proof PCB transformer
AVB
Typ AVB 0,35/2/.. AVB 0,5/2/.. AVB 1,0/2/.. AVB 1,5/2/.. AVB 2,0/2/.. AVB 2,3/2/..
Input
Rated input voltage 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac
Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Output
Rated output voltage: Order no. 2x6 Vac: AVB 0,35/2/6
2x9 Vac: AVB 0,35/2/9
2x12 Vac: AVB 0,35/2/12
2x18 Vac: AVB 0,35/2/18*
2x24 Vac: AVB 0,35/2/24*
2x6 Vac: AVB 0,5/2/6
2x8 Vac: AVB 0,5/2/8
2x9 Vac: AVB 0,5/2/9
2x12 Vac: AVB 0,5/2/12
2x15 Vac: AVB 0,5/2/15*
2x18 Vac: AVB 0,5/2/18*
2x24 Vac: AVB 0,5/2/24*
2x6 Vac: AVB 1,0/2/6
2x9 Vac: AVB 1,0/2/9
2x12 Vac: AVB 1,0/2/12
2x15 Vac: AVB 1,0/2/15
2x18 Vac: AVB 1,0/2/18*
2x24 Vac: AVB 1,0/2/24*
2x6 Vac: AVB 1,5/2/6
2x8 Vac: AVB 1,5/2/8
2x9 Vac: AVB 1,5/2/9
2x12 Vac: AVB 1,5/2/12
2x15 Vac: AVB 1,5/2/15
2x18 Vac: AVB 1,5/2/18*
2x24 Vac: AVB 1,5/2/24*
2x12 Vac: AVB 2,0/2/12 2x6 Vac: AVB 2,3/2/6
2x9 Vac: AVB 2,3/2/9
2x12 Vac: AVB 2,3/2/12
2x15 Vac: AVB 2,3/2/15
2x18 Vac: AVB 2,3/2/18*
2x24 Vac: AVB 2,3/2/24*
Rated Power 0,35 VA 0,5 VA 1 VA 1,5 VA 2 VA 2,3 VA
No-load voltage (app. x factor) 1.80 1.80 1.32 1.39 1.43 1.43
No-load loss (typ.) 1.30 W 1.10 W 0.90 W 1.00 W 0.90 W 0.90 W
Efficiency 30.0 % 40.0 % 55.0 % 57.0 % 43.0 % 59.0 %
Standards
Classification Safety isolating transformer
*Mains transformer
Safety isolating transformer
*Mains transformer
Safety isolating transformer
*Mains transformer
Safety isolating transformer
*Mains transformer
Safety isolating transformer Safety isolating transformer
*Mains transformer
Approvals
Approvals cURus cURus cURus cURus cURus cURus
Environment
Ambient temperature max. 70 °C 70 °C 70 °C 70 °C 70 °C 70 °C
Safety and protection
Type Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated
Insulation class VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105
Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00
Safety class (prepared) II II II II II II
Short circuit strength inherently short-circuit
proof
inherently short-circuit
proof
inherently short-circuit
proof
inherently short-circuit
proof
inherently short-circuit
proof
inherently short-circuit
proof
Order numbers
Order Number see rated output voltage see rated output voltage see rated output voltage see rated output voltage see rated output voltage see rated output voltage
+
-
Short-circuit proof PCB transformer
AVB
Typ AVB 2,3/2/.. AVB 3,2/2/..
Input
Rated input voltage 2 x 115 Vac 2 x 115 Vac
Rated frequency 50 - 60 Hz 50 - 60 Hz
Output
Rated output voltage: Order no. 2x8 Vac: AVB 2,3/2/8 2x6 Vac: AVB 3,2/2/6
2x9 Vac: AVB 3,2/2/9
2x12 Vac: AVB 3,2/2/12
2x15 Vac: AVB 3,2/2/15
2x18 Vac: AVB 3,2/2/18
2x24 Vac: AVB 3,2/2/24*
Rated Power 2,3 VA 3,2 VA
No-load voltage (app. x factor) 1.43 1.57
No-load loss (typ.) 0.90 W 1.00 W
Efficiency 59.0 % 58.0 %
Standards
Classification Safety isolating transformer Safety isolating transformer
*Mains transformer
Approvals
Approvals cURus cURus
Environment
Ambient temperature max. 70 °C 50 °C
Safety and protection
Type Encapsulated Encapsulated
Insulation class VDE=B, UL=class 105 VDE=B, UL=class 105
Protection index IP 00 IP 00
Safety class (prepared) II II
Short circuit strength inherently short-circuit
proof
inherently short-circuit
proof
Order numbers
Order Number see rated output voltage see rated output voltage
+
-
Transformers
PCB transformers
1
BLOCK
Website
254 Subject to change
Short-circuit proof PCB transformer
AVB
Typ AVB 0,35/2/.. AVB 0,5/2/.. AVB 1,0/2/.. AVB 1,5/2/.. AVB 2,0/2/.. AVB 2,3/2/..
Input
Rated input voltage 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac 2 x 115 Vac
Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz
Output
Rated output voltage: Order no. 2x6 Vac: AVB 0,35/2/6
2x9 Vac: AVB 0,35/2/9
2x12 Vac: AVB 0,35/2/12
2x18 Vac: AVB 0,35/2/18*
2x24 Vac: AVB 0,35/2/24*
2x6 Vac: AVB 0,5/2/6
2x8 Vac: AVB 0,5/2/8
2x9 Vac: AVB 0,5/2/9
2x12 Vac: AVB 0,5/2/12
2x15 Vac: AVB 0,5/2/15*
2x18 Vac: AVB 0,5/2/18*
2x24 Vac: AVB 0,5/2/24*
2x6 Vac: AVB 1,0/2/6
2x9 Vac: AVB 1,0/2/9
2x12 Vac: AVB 1,0/2/12
2x15 Vac: AVB 1,0/2/15
2x18 Vac: AVB 1,0/2/18*
2x24 Vac: AVB 1,0/2/24*
2x6 Vac: AVB 1,5/2/6
2x8 Vac: AVB 1,5/2/8
2x9 Vac: AVB 1,5/2/9
2x12 Vac: AVB 1,5/2/12
2x15 Vac: AVB 1,5/2/15
2x18 Vac: AVB 1,5/2/18*
2x24 Vac: AVB 1,5/2/24*
2x12 Vac: AVB 2,0/2/12 2x6 Vac: AVB 2,3/2/6
2x9 Vac: AVB 2,3/2/9
2x12 Vac: AVB 2,3/2/12
2x15 Vac: AVB 2,3/2/15
2x18 Vac: AVB 2,3/2/18*
2x24 Vac: AVB 2,3/2/24*
Rated Power 0,35 VA 0,5 VA 1 VA 1,5 VA 2 VA 2,3 VA
No-load voltage (app. x factor) 1.80 1.80 1.32 1.39 1.43 1.43
No-load loss (typ.) 1.30 W 1.10 W 0.90 W 1.00 W 0.90 W 0.90 W
Efficiency 30.0 % 40.0 % 55.0 % 57.0 % 43.0 % 59.0 %
Standards
Classification Safety isolating transformer
*Mains transformer
Safety isolating transformer
*Mains transformer
Safety isolating transformer
*Mains transformer
Safety isolating transformer
*Mains transformer
Safety isolating transformer Safety isolating transformer
*Mains transformer
Approvals
Approvals cURus cURus cURus cURus cURus cURus
Environment
Ambient temperature max. 70 °C 70 °C 70 °C 70 °C 70 °C 70 °C
Safety and protection
Type Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated Encapsulated
Insulation class VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105
Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00
Safety class (prepared) II II II II II II
Short circuit strength inherently short-circuit
proof
inherently short-circuit
proof
inherently short-circuit
proof
inherently short-circuit
proof
inherently short-circuit
proof
inherently short-circuit
proof
Order numbers
Order Number see rated output voltage see rated output voltage see rated output voltage see rated output voltage see rated output voltage see rated output voltage
+
-
Short-circuit proof PCB transformer
AVB
Typ AVB 2,3/2/.. AVB 3,2/2/..
Input
Rated input voltage 2 x 115 Vac 2 x 115 Vac
Rated frequency 50 - 60 Hz 50 - 60 Hz
Output
Rated output voltage: Order no. 2x8 Vac: AVB 2,3/2/8 2x6 Vac: AVB 3,2/2/6
2x9 Vac: AVB 3,2/2/9
2x12 Vac: AVB 3,2/2/12
2x15 Vac: AVB 3,2/2/15
2x18 Vac: AVB 3,2/2/18
2x24 Vac: AVB 3,2/2/24*
Rated Power 2,3 VA 3,2 VA
No-load voltage (app. x factor) 1.43 1.57
No-load loss (typ.) 0.90 W 1.00 W
Efficiency 59.0 % 58.0 %
Standards
Classification Safety isolating transformer Safety isolating transformer
*Mains transformer
Approvals
Approvals cURus cURus
Environment
Ambient temperature max. 70 °C 50 °C
Safety and protection
Type Encapsulated Encapsulated
Insulation class VDE=B, UL=class 105 VDE=B, UL=class 105
Protection index IP 00 IP 00
Safety class (prepared) II II
Short circuit strength inherently short-circuit
proof
inherently short-circuit
proof
Order numbers
Order Number see rated output voltage see rated output voltage
+
-
Transformers
PCB transformers
1
BLOCK
Website
255
Subject to change
1.1
1.2
5.1
1.3
2.1
2.2
3.1
3.2
3.3
5.2
4.0
Short-circuit proof PCB transformer
AVB
Typ
Terminals
Pin (ø)
Core type
Weight
Dimension picture (in mm)
A B C D E F G H
AVB 0,35/2/.. Pins for printed circuit boards 0.6 EE 20/6,1 0.02 kg 122 22.7 15 15 15 5 - 5
AVB 0,5/2/.. Pins for printed circuit boards 0.6 EE 20/10,5 0.04 kg 122 22.7 19 15 15 5 - 5
AVB 1,0/2/.. Pins for printed circuit boards 0.8 EI 30/10,5 0.07 kg 232.3 27.3 21.8 20 20 10 5 5
AVB 1,5/2/.. Pins for printed circuit boards 0.8 EI 30/12,5 0.08 kg 232.3 27.3 23.8 20 20 10 5 5
AVB 2,0/2/.. Pins for printed circuit boards 0.8 EI 30/15,5 0.10 kg 232.3 27.3 26.8 20 20 10 5 5
AVB 2,3/2/.. Pins for printed circuit boards 0.8 EI 30/18 0.10 kg 232.3 27.3 29 20 20 10 5 5
AVB 2,3/2/.. Pins for printed circuit boards 0.8 EI 30/18 0.11 kg 232.3 27.3 39 20 20 10 5 5
AVB 3,2/2/.. Quick connect terminals 0.6 x 0.8 EI 38/16,5 0.17 kg 241 35 30.8 20 25 10 5 5
30
Dimension pictures
PCB transformer
VC
General Data
Rated input voltage 230 Vac
Rated output voltage 6 - 2 x 24 Vac
Rated power 3.2 - 16 VA
Insulation class B
Maximum ambient temperature 40 - 60 °C
Efficiency up to 76 %
Degree of protection IP 00
Advantages
Minimum size at high output
Also with dual output voltage for series or parallel connection
Permanent corrosion protection, high insulation value and maximum
electrical reliability thanks to XtraDenseFill resin encapsulation
Self-extinguishing potting material
Applications
As a mains transformer for adjustment of the voltage and simple electrical
isolation.
As a safety transformer for the safe electrical isolation of the input and output
sides. The transformer is suitable for creating SELV and PELV circuits because
of the limit on the output voltage.
Sample applications
Standards / 2 Z
Approvals W J w Z
Mains transformer
to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL
5085-1/-2, CSA 22.2 No.66
Safety isolating transformer
to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL
5085-1/-2, CSA 22.2 No.66
VDE, UL 5085-1/-2, CSA 22.2 No.66
Transformers
PCB transformers
1
BLOCK
Website
256 Subject to change