10 Watt
2” x 1”
Single &
Dual Output
44::11 WWiiddee IInnppuutt VVoollttaaggee RRaannggee
1100 WWaattttss OOuuttppuutt PPoowweerr
11..66kkVVDDCC IIssoollaattiioonn
FFiixxeedd OOppeerraattiinngg FFrreeqquueennccyy
SSiixx--SSiiddeedd CCoonnttiinnuuoouuss SShhiieelldd
SSttaannddaarrdd 5500..88 xx2255..44xx1100..22mmmm PPaacckkaaggee
EEffffiicciieennccyy ttoo 8844%%
Features
Selection Guide 24V and 48V Input Types
Part Number Input Output Output Input(4) Efficiency(5) Capacitive(6)
Range Voltage Current Current Load max.
VDC VDC mA mA %
RP10-2405SEW 9-36 5 2000 548 80 4700µF
RP10-2412SEW 9-36 12 830 532 82 690µF
RP10-2415SEW 9-36 15 670 551 80 470µF
RP10-4805SEW 18-75 5 2000 274 80 4700µF
RP10-4812SEW 18-75 12 830 259 84 690µF
RP10-4815SEW 18-75 15 670 262 84 470µF
RP10-2405DEW 9-36 ±5 ±1000 548 80 ±680µF
RP10-2412DEW 9-36 ±12 ±416 547 80 ±330µF
RP10-2415DEW 9-36 ±15 ±333 548 80 ±110µF
RP10-4805DEW 18-75 ±5 ±1000 271 81 ±680µF
RP10-4812DEW 18-75 ±12 ±416 281 78 ±330µF
RP10-4815DEW 18-75 ±15 ±333 270 81 ±110µF
* add suffix /M2 for higher efficiencies and extended temperature range.
* add suffix /Pfor CTRL function with Positive Logic (1=ON, 0=OFF)
* add suffix /Nfor CTRL function with Negative Logic (0=ON, 1=OFF)
* add suffix -HC for premounted heatsink and clips
Ordering Examples
RP10-2405SE/P = 24V 4:1 Input, 5V Output, Standard Temp. Range, Positive Logic CTRL pin fitted
RP10-4805DE/M1-HC = 48V 4:1Input, ±5V Output, Extended Temp. Range, No CTRL, Heatsink fitted
Description
The RP10-EW series wide input range DC/DC converterc are certified to UL 60950-1 and cUL 60950-1. This
makes them ideal for all telecom and industrial applications where approved safety standards are required.
The industry standard 2” x 1” package meets military standards for thermal shock and vibration tolerance and is
available with an optional remote on/off control pin.
This series is also available with the /M2 option which is particularly suitable for extended temperature range ap-
plications.
UL-60950-1 Certified
E196683
RP10-EW
POWERLINE
DC/DC-Converter
Please Read Application
Notes
RP10-EW
REV: 0/2009 www.recom-electronic.com
P-12
POWERLINE
DC/DC-Converter RP10-S_DEW
Series
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25 -10 0 50 60 70 80 90 100
Output Power (%)
Natural Convection
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25 -10 0 50 60 70 80 90 100
Output Power (%)
75
Natural Convection
RP10-2405SEW RP10-2405SEW With Heat Sink
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25 -10 0 50 60 70 80 90 100
Output Power (%)
74
Natural Convection
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25 -10 0 50 60 70 80 90 100
Output Power (%)
78
Natural Convection
RP10-2405DEW RP10-2405DEW With Heat Sink
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25 -10 0 50 60 70 80 90 100
Output Power (%)
Natural Convection
-40
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25 -10 0 50 60 70 80 90 100
Output Power (%)
75
Natural Convection
-40
RP10-2405SEW/M2 RP10-2405SEW/M2 With Heat Sink
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25 -10 0 50 60 70 80 90 100
Output Power (%)
74
Natural Convection
-40
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25 -10 0 50 60 70 80 90 100
Output Power (%)
78
Natural Convection
-40
RP10-2405DEW/M2 RP10-2405DEW/M2 With Heat Sink
Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical support service at info@recom-development.at
Derating Graph (Ambient Temperature)
REV:0/2009 P-13
www.recom-international.com
RP10-EW
Specifications (typical at nominal input and 25°C unless otherwise noted)
POWERLINE
DC/DC-Converter
RP10-S_DEW
Series
Input Voltage Range 24V nominal input 9-36VDC
48V nominal input 18-75VDC
Input Filter Pi Type
Input Surge Voltage (100 ms max.) 24V Input 50VDC
48V Input 100VDC
Input Reflected Ripple (nominal Vin and full load) 30mAp-p
Start Up Time (nominal Vin and constant resistor load) 20ms typ.
Remote ON/OFF (Optional. See Note 7)
(Positive logic) DC-DC ON Open or 3.5V < Vr < 12V
DC-DC OFF Short or 0V < Vr < 1.2V
(Negative logic) DC-DC ON Short or 0V < Vr < 1.2V
DC-DC OFF Open or 3.5V < Vr < 12V
Remote OFF input current Nominal input 20mA
Output Power 10W max.
Output Voltage Accuracy (full Load and nominal Vin) ±2%
Minimum Load (see Note 1) 10% of full load
Line Regulation (low line, high line at full load) ±1%
Load Regulation (25% to 100% full load) Single ±1%
Dual ±2%
Cross Regulation (asymmetrical 25%<>100% load) ±5%
Ripple and Noise (20MHz bandwith) Single 50mVp-p
Dual 75mVp-p
Temperature Coefficient ±0.02%/°C max.
Transient Response (25% load step change) 500µs
Over Voltage Protection 5V output 6.2V
Zener diode clamp 12V output 15V
15V output 18V
Over Load Protection (% of full load at nominal Vin) 150% typ
Undervoltage Lockout none
Short Circuit Protection Hiccup, automatic recovery
Efficiency see „Selection Guide“ table
Isolation Voltage 1600VDC min.
Isolation Resistance 1 Gmin.
Isolation Capacitance 300pF max.
Operating Frequency 300kHz typ.
Operating Temperature Range Standard -25°C to +85°C(with derating)
(Reference Derating Curve) (see Note 9) M2 -40°C to +85°C(with derating)
Maximum Case Temperature +100°C
Storage Temperature Range -55°C to +125°C
Thermal Impedance Natural convection 12°C/Watt
(see Note 8) Natural convection with Heat Sink 10°C/Watt
Thermal Shock MIL-STD-810D
Vibration 10-55Hz, 10G, 30 Min. along X, Y and Z
Relative Humidity 5% to 95% RH
Case Material Nickel plated copper
Base Material Non-conductive black plastic
Potting Material Epoxy (UL94-V0)
continued on next page
RP10-EW
REV: 0/2009 www.recom-electronic.com
P-14
Package Style and Pinning (mm)
3
1
2
5
4
20.30
50.80
dia.
1.0
10.20
10.20
12.70
15.20
Bottom View
6
2.50
5.10
25.40
5.6
10.20
3rd angle
projection
Pin Pitch Tolerance ±0.35 mm
Pin Connections
Pin # Single Dual
1 +Vin +Vin
2 -Vin -Vin
3 +Vout +Vout
4 No Pin Com
5 -Vout -Vout
6* CTRL* CTRL*
* Optional. See Note 7
Specifications (typical at nominal input and 25°C unless otherwise noted)
POWERLINE
DC/DC-Converter
Conducted Emissions (see Note 10) EN55022 Level A
Radiated Emissions EN55022 Level A
ESD EN61000-4-2 Perf. Criteria B
Radiated Immunity EN61000-4-3 Perf. Criteria B
Fast Transient EN61000-4-4 Perf. Criteria B
Surge EN61000-4-5 Perf. Criteria B
Conducted Immunity EN61000-4-6 Perf. Criteria B
Weight 27g
Dimensions 50.8 x 25.4 x 10.2mm
MTBF (see Note 2) 1976 x 103hours
RP10-S_DEW
Series
Notes :
1. The RP10 (W) series required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices, however they may not meet all listed specification.
2. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment).
3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input.
Positive logic ON/OFF is marked with suffix-P (eg. RP10-2405SEW/P)
Negative logic ON/OFF is marked with suffix-N (eg. RP10-2405SEW/N).
If no suffix is specified, the control pin will be omitted.
8. Heat sink is optional and P/N: 7G-0020C. Powerline DC/DC Converters can be ordered with pre-mounted heatsinks including antivibration fixing clips
(add suffix -HC). See Application Notes for heatsink details.
9. M2 version is more efficient, therefore, it can be operated in a more extensive temperature range than standard version.
10. See application notes for EMI-filtering.
REV:0/2009 P-15
www.recom-international.com
RP10-EW