www.tracopower.com Page 3 of 9
Industrial Power Supplies
TSPC Series 50–480 Watt
General Specifications
Reliability, calculated MTBF at +25°C acc. to IEC 61709 – TSPC 080 2.4 Mio. h
– TSPC 120 2.5 Mio. h
– TSPC 240 1.7 Mio. h
– TSPC 480 1.4 Mio. h
Isolation according to IEC/EN 60950-1, UL 60950-1, UL 508
Safety standards – Information technology equipment
IEC/EN 60950-1, UL 60950-1, CSA 22.2 No 60950-1-07
– Industrial control equipment UL 508,
CSA-C22.2 N o.107
– Electrical equipment for machines EN 60204-1
– Electronic equipment for power installation EN 50178
– Safety of transformers EN 61558-2-6, EN 61558-2-16
– Control equipment for hazardous location EN 60079-15 II3G EX nA IIC T4
– ATEX (for IP 54 enclosure) certificate no. EPS 10 ATEX 1 269 X
– UL hazloc (TSPC 050-124HL only) UL 121201 Class I; Div 2; Groups A,B,C & D; T4
– Certification documents www.tracopower.com/overview/tspc
Class of protection safety class I (IEC 536)
Degree of protection IP 20 (IEC/EN 60529)
Electromagnetic compatibility (EMC), Emissions EN 61000-6-3, EN 61204-3
– Conducted RI suppression on input EN 55011 class B, EN 55022 class B,
– Radiated RI suppression EN 55011 class B, EN 55022 class B,
Electromagnetic compatibility (EMC), Immunity EN 61000-6-2, EN 61204-3
– Electrostatic discharge (ESD) IEC/EN 61000-4-2 4 kV / 8 kV criteria B
– Radiated RF field immunity IEC/EN 61000-4-3 10 V / m criteria A
– Electrical fast transient / burst immunity IEC/EN 61000-4-4 2 kV criteria B
– Surge immunity IEC/EN 61000-4-5 1 kV / 2 kV criteria B
– Immunity to conducted RF disturbances IEC/EN 61000-4-6 10 V criteria A
– Power frequency field immunity IEC/EN 61000-4-8 30 A / m criteria A
– Mains voltage dips and interruptions IEC/EN 61000-4-11 criteria B/C
Environment – Vibration acc. IEC 68-2-6; 3 axis, sine sweep, 10 – 55 Hz, 1 g, 1 oct/min
– Shock acc. IEC 60068-2-27 3 axis, 15 g half sine, 11 ms
Enclosure material aluminium (chassis) / stainless steel (cover)
Mounting – DIN-rail mounting for DIN-rails as per EN 50022-35x15/7.5
(snap-on with self-locking spring)
– Wall mounting (option) with wall mounting bracket - see page 12
Environmental compliance – Reach www.tracopower.com/info/reach-declaration.pdf
– RoHS RoHS directive 2011/65/EU
Connection – Input / Output screw terminals
– Power Good signal (mating connector) Phoenix contact MC 1,5/2-ST-3,5 (not included)
Installation instructions www.tracopower.com/overview/tspc
Accessories (optional)
Decoupling module for redundant operation see:
www.tracopower.com/products/tspc-dcm.pdf
Wall mounting brackets: see last page