SIF 6 Contacts
Relay data General data Diagrammes
Circuit diagram (view on relay upper side)
- PCB relay with forcibly guided contacts
- Protective separation between coil and
contacts (> 5.5 mm) and contacts side by
side (> 5.5 mm)
- EN 50205 type A
- Double and reinforced insulation
- SMD arrangement below relay possible
- Contact mounting: SIF422 4NO/2NC
- Compact height: only 10.9mm
- Mean coil power 0.66W (holding power
0.20W)
Nominal voltage
VDC
Min. pick-up
voltage at 20°C
VDC
Drop-out voltage
at 20 °C
VDC
Nominal current
in mA
Resistance in
Ohm at 20 °C
Tolerance in %
5 < 3.5 > 0.5 133.3 37.5 ± 10
12 < 8.4 > 1.2 55.8 215 ± 10
20 < 14.0 > 2.0 33.3 600 ± 10
24 < 16.8 > 2.4 27.5 870 ± 10
48 < 33.6 > 4.8 13.8 3‘460 ± 10
60 < 42.0 > 6.0 11.1 5‘400 ± 13
110 < 77.0 > 11.0 6.0 18‘300 ± 15
Contact material AgCuNi + 0.2 µm Au
Type of contact single contact with notched crown
Rated switching capacity 250VAC 8A AC1 2000VA
Electr. life AC1 (360 S/h) approx.100‘000
Inrush current max. 30A for 20ms
Switching voltage range 5 bis 440VDC/VAC
Switching current range* 5mA to 8A
Switching capacity range* 60mW to 2000W (VA)
Contact resistance (as delivered)) < 100m
* Guide values
Mechanical life > 10 x 106 operations
Switching frequency, mechanical 15Hz
Response time typically 20ms
Drop-out time** typically 8ms
Bounce time of NO contact typically 3ms
Bounce time of NC contact typically 12ms
Shock resistance NO contact 10g
NC contact 6g
Vibration resistance NO contact 10g
10-200Hz NC contact 2g
Test voltage
coil to contacts 4‘000Veff 1min
Test voltage
contacts against each other 4’000Veff 1min
Test voltage contact open 1’500Veff 1min
Insulation resistance at Up 500V 108
Creeping resistance CTI 175
Weight approx. 35g
Mounting position any
Ambient temperature -40°C to +70°C
Type of protection RT III (IP67)
Solder bath temperature 270°C/5s
Thermal resistance 47K/W
Temperature limit for coil 120°C
Pollution degree 3
Overvoltage category III
Resistance to 1‘000A SCPD 10A AK
short circuiting 6A RK
gL/gG (pre-fuse)
** without spark suppression
Insulation terms
Double or reinforced insulation >5.5mm
between all current circuits
Tests, regulations
Approvals (in preparation) SEV, UL, cUL, TÜV
Insulation class VDE 0110 / group C 250VAC
Protection class II VDE 0106
Fire protection requirements UL 94 / V0
Ordering example
[mm]
10,9
3,1
2,9
2,2
53,6
7,57,515,4
1,6
3,3
3,1
1,5
3,1
3,1
4,1
4,1 15,815,815,8
33,5
30,4
1,6 1,5
10,3
3,1
47,4
Ø1,3
Max. switching characteristics
(DIN EN 60947-4-1/ EN 60947-5-1):
AC 1: 250V/8A
AC 15: 230V/6A
DC 1: 24V/8A
DC 13: 24V/5A/0.1Hz
Maximal contact load at AC 1 with 230V:
2 contacts each with 8A
3 contacts each with 6A
4 contacts each with 4.5A
Contact lifetime
1) Max. excitation voltage with contact load < 6A
2) Min. excitation voltage (guaranteed values)
without previous operation
No heat accumulation due to intrinsic heating
of other components.
Continuous duty 100%..
Excitation voltage range
Load limit curve with direct current
Made in Switzerland 0549
c
us
S
E-Nr. 300997
SIF422
24V
8A 250V~AC1
DC
www.elestarelays.com
53
54 63 64
34 33 43 44
12 11 21 22
A1 A2
Type A
Standard coils for direct current (examples)
other voltages on request
SIF 4 2 2 24VDC
Soldering tags
Number of NC contacts
Number of NO contacts
Type designation
Coil voltage
SIF-422
Double or reinforced insulation
A1 A2
12 22
11 21
34 44
33 43
54 64
53 63
1000
1000
10000
1000000
0.5
No. of operations x 1000
Switching current (A)
0.1 1 2 3 4 5 6 7 8 910
Kontaktlebensdauer
DC1
AC1
AC15
DC13
500
300
200
100
70
50
30
20
10
0.1 0.2 0.3 0.5 0.7 1.0 2 3 4 5 6 7 8 10
Current (A)
10 W
20 W
40 W
60 W
80 W
100 W
150 W
200 W
250 W
300 W
Voltage (VDC)
Lastgrenzkurve bei Gleichstrom
0
020 40 60
2.0
1.5
1.0
0.5
80 100
Erregerspannungsbereich
2.5
2
1
Ambient temperature °C
UB
N
U
American Electronic Components, Inc.
1101 Lafayette Street, Elkhart, IN 46516, Tel: (574) 295-6330, Fax: (574) 293-8013, sales@aecsensors.com