SPECIFICATION
LPS-100-3.3 LPS-100-5 LPS-100-7.5 LPS-100-12 LPS-100-13.5 LPS-100-15 LPS-100-24 LPS-100-27 LPS-100-48
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY(Typ.)
INPUT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
3.3V 5V 7.5V 12V 13.5V 24V 27V 48V
20A 20A 13.3A 8.4A 7.5A 6.7A 4.2A 3.8A 2.1A
0~20A 0~20A 0~13.3A 0~8.4A 0~7.5A 0~6.7A
0~4.2A(6A 10s)
100.8W(144W10s)
0~3.8A 0~2.1A
66W 100W 99.75W 100.8W 101.25W 100.5W 102.6W 100.8W
150mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 200mVp-p
3~3.6V 4.5~5.7V 6~9V 10~13.2V 12~15V 13.5~18V 20~26.4V 26~32V 41~56V
3.0% 3.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0%
0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5%
2.0% 2.0% 1.5% 1.5% 1.5% 1.5% 0.5% 0.5% 0.5%
800ms,50ms/230VAC1200ms,50ms/115VACatfullload
20ms/230VAC20ms/115VACatfullload
88~132VAC/176~264VACautoswitch248~370VDC
47~63Hz
69% 77% 77% 79% 79% 80% 80% 81% 81%
2.3A/115VAC1.5A/230VAC
COLDSTART 30A/115VAC60A/230VAC
<1mA /240VAC
105~140%(+24V:above6.5A) ratedoutputpower
3.8~4.45V 5.75~6.75V 9.4~10.9V 13.8~16.2V 15.5~18.2V 18~21V 27.6~32.4V 33.7~39.2V 57.6~67.2V
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
20~90%RHnon-condensing
-10~+60 (Referto"DeratingCurve")
-20~+85 ,10~95%RH
0.05%/ (0~50
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
203.6Khrsmin.MIL-HDBK-217F(25 )
222*62*32mm(L*W*H)
0.45Kg;24pcs/12.5Kg/1.39CUFT
FileName:LPS-100-SPEC2011-08-10
SAFETY STANDARDS UL60950-1, TUVEN60950-1approved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2,-3
Complianceto EN61000-4-2,3,4,5,6,11,lightindustrylevel,criteria A
100WSingleOutputwithoutPFCFunction LPS-100 seri e s
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
100% full load burn-in test
Fix switching frequency at 134KHz
2 years warranty
Features :
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC /25 /70%RH
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. If the input range 85V-89V, the output load is changed from 0A-rated load, There will be reduced 20V for 1second (LPS-100-24).
6. Mounting holes M1 and M2 should be grounded for EMI purposes.
For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
15V
EMCIMMUNITY
EMCEMISSION