APPLICATIONS / BENEFITS
¾ Protection from switching transients and induced RF
¾ ESD & EFT protection per IEC 61000-4-2 and -4-4
¾ Secondary lightning protection per IEC61000-4-5 with 42 Ohms source impedance:
Class 1: 1N5629 to 1N5665A
Class 2: 1N5629 to 1N5663A
Class 3: 1N5629 to 1N5655A
Class 4: 1N5629 to 1N5648A
¾ Secondary lightning protection per IEC61000-4-5 with 12 Ohms source impedance:
Class 1: 1N5629 to 1N5658A
Class 2: 1N5629 to 1N5651A
Class 3: 1N5629 to 1N5643A
Class 4: 1N5629 to 1N5636A
¾ Secondary lightning protection per IEC61000-4-5 with 2 Ohms source impedance:
Class 2: 1N5629 to 1N5642A
Class 3: 1N5629 to 1N5635A
¾ Inherently radiation hard per Microsemi MicroNote 050
MAXIMUM RATINGS
¾ 1500 Watts for 10/1000 μs with repetition rate of 0.01% or less* at lead temperature (TL) 25oC (see Figs 1, 2, & 4)
¾ Operating & Storage Temperatures: -65o to +175oC
¾ THERMAL RESISTANCE: 50oC/W junction to lead at 0.375 inches (10 mm) from body or 110oC/W junction to
ambient when mounted on FR4 PC board with 4 mm2 copper pads (1oz) and track width 1 mm, length 25 mm
¾ DC Power Dissipation*: 1 Watt at TL ≤ +125oC 3/8” (10 mm) from body (see derating in Fig 3 and note below)
¾ Forward surge current: 200 Amps for 8.3ms half-sine wave at TA = +25oC
¾ Solder Temperatures: 260 o C for 10 s (maximum)
MECHANICAL AND PACKAGING
¾ CASE: DO-13 (DO-202AA), welded, hermetically sealed metal and glass
¾ FINISH: All external metal surfaces are Tin-Lead plated and solderable per MIL-STD-750 method 2026
¾ POLARITY: Cathode connected to case and polarity indicated by diode symbol
¾ MARKING: Part number and polarity diode symbol
¾ WEIGHT: 1.4 grams. (Approx)
¾ TAPE & REEL option: Standard per EIA-296 (add “TR” suffix to part number)
¾ See package dimension on last page
* TVS devices are not typically used for dc power dissipation and are instead operated at or less than their rated
standoff voltage
(VWM) except for transients that briefly drive the device into avalanche breakdown (VBR to VC region).